Parker Balston LCMS-5001TNA 气体发生器 PDF资料
Parker Balston LCMS-5001TNA 是专为LC/MS系统设计的三气体发生器,型号对应SOURCE 5000系列,可同时提供高纯氮气、零级空气和干燥空气。
产品特点
三气一体化输出,同时提供氮气、零级空气和干燥空气。
氮气纯度高达99.999%且不含邻苯二甲酸酯,满足痕量分析要求。
采用静音涡旋压缩机,运行噪音较低。
即插即用设计,无需外接高压气瓶,节省实验室空间。
该产品已停产,市面流通的通常为翻新或二手设备。
产品参数
品牌:Parker Balston。
型号:LCMS-5001TNA,对应SOURCE 5000系列。
流量:氮气最高10L/min,零级空气最高23L/min,干燥空气最高8L/min。
纯度:氮气纯度≥99.999%,碳氢化合物<0.1ppm。
电源与重量:120VAC,3A,重量约123公斤。
应用领域
LC/MS/MS仪器的幕帘气、源气和排气供气。
分析实验室中的高纯氮气和零级空气供应。
替代高压气瓶,用于持续稳定的分析仪器供气。
需要无邻苯二甲酸酯污染气体的痕量分析环境。
实验室气体供应系统的集中化配套与设备维护替换。
结尾
Parker Balston LCMS-5001TNA将三种气体集成于一体,是专为LC/MS系统打造的气体供应解决方案,在分析实验室设备配套和系统维护中具有实用价值
Parker Balston LCMS-5001TNA 气体发生器 英文介绍
Parker Balston LCMS-5001TNA is a three gas generator designed specifically for LC/MS systems, corresponding to the SOURCE 5000 series. It can provide high-purity nitrogen, zero order air, and dry air simultaneously.
Product Features
Integrated output of three gases, providing nitrogen, zero level air, and dry air simultaneously.
The purity of nitrogen is as high as 99.999% and does not contain phthalates, meeting the requirements for trace analysis.
Using a silent vortex compressor, the operating noise is relatively low.
Plug and play design, no need for external high-pressure gas cylinders, saving laboratory space.
This product has been discontinued and is usually refurbished or used equipment in circulation on the market.
Product Parameters
Brand: Parker Balston.
Model: LCMS-5001TNA, corresponding to the Source 5000 series.
Flow rate: nitrogen up to 10L/min, zero level air up to 23L/min, dry air up to 8L/min.
Purity: Nitrogen purity ≥ 99.999%, hydrocarbons<0.1ppm.
Power supply and weight: 120VAC, 3A, weighing approximately 123 kilograms.
Application Areas
Curtain gas, source gas, and exhaust gas supply for LC/MS/MS instruments.
Analyze the supply of high-purity nitrogen and zero order air in the laboratory.
Replace high-pressure gas cylinders for continuous and stable supply of gas to analytical instruments.
A trace analysis environment without phthalate ester contaminated gases is required.
Centralized matching and equipment maintenance replacement of laboratory gas supply system.
ending
Parker Balston LCMS-5001TNA integrates three gases into one and is a gas supply solution specifically designed for LC/MS systems. It has practical value in equipment matching and system maintenance in analytical laboratories
Parker Balston LCMS-5001TNA 气体发生器 产品图片

3.其他产品
ICS TRIPLEX T9451 数字输入模块
KOLLMORGEN S22460-SRS 伺服驱动器
CI860K01 3BSE032444R1通信接口模块
4.其他产品
E69F-B12-S converter module
FBM201 output signal module
Advantest A000824B-DED BGR-022365 card
| AMAT 0100-01108 | TP-1358-1 | 6SL3352-1AG41-3FA1 |
| AMAT 0100-91119 | TP-2296-3 | 0090-07135 |
| AMAT 0100-09304 | TP-2322-5 | CI867 3BSE043660R1 |
| AMAT 0100-76252 | TP-8070-5 | 3ASC25H209 DATX110 |
| AMAT 0100-00986 | TP-1229-0 | 3ASC25H209 |
| AMAT 0100-20068 | TP-7216-4 | 8502-B1-DP |
| AMAT 0100-90135 | TP-2180-1 | 758-873 |
本篇文章出自瑞昌明盛自动化设备有限公司官网,转载请附上此链接:https://www.jiangxidcs.com