ABB SDCS-CON-4 3ADT313900R1501模块卡件1.产 品 详 情 资 料: 故障LED亮起,电源内部短路或过电压导致3.3 V。•用电压表检查外部24 V电压。•将装置送去维修。运行指示灯关闭硬件错误。•将装置送去维修。连接外部电源时,内部保险丝熔断(BC810)外部保险丝熔断(TP857)EPOK LED熄灭硬件错误。外...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

ABB SDCS-CON-4 3ADT313900R1501模块卡件

    ABB SDCS-CON-4 3ADT313900R1501模块卡件


    1.产      品      详      情      资      料:   

    故障LED亮起,电源内部短路或过电压导致3.3 V。•用电压表检查外部24 V电压。•将装置送去维修。运行指示灯关闭硬件错误。•将装置送去维修。连接外部电源时,内部保险丝熔断(BC810)外部保险丝熔断(TP857)EPOK LED熄灭硬件错误。外部保险丝熔断(TP857)•送装置维修。尽管未使用中断(例如CI851)访问CEX单元CEX总线单元,但C1或C2 LED熄灭,无需采取任何措施。R(un)或F(ault)LED均不亮SM810/SM811板正在重新启动或配置过程中。留出时间完成。如果情况依然存在,并且CEX总线上的其他单元LED没有点亮:•检查日志文件•检查CPU单元内的CEX总线保险丝。•从CPU单元启动复位信号(INIT)。•更换SM810/SM811装置。F(故障)LED亮起装置错误。更换SM810/SM811装置。PRIM LED闪烁装置错误。更换SM810/SM811装置。PRIM LED在单个配置中关闭。单元错误。更换SM810/SM811装置。SYNC LED闪烁,正在升级。当LED以对称模式闪烁时,请留出时间完成此操作。如果LED闪烁3次并暂停序列,则SM811已准备好确认SIL3热插入,请参阅第278页的SM811和TP868。如果这种情况持续更长时间,请更换SM810/SM811装置。

    Fault LED is ON No 3.3 V caused by internal short circuit or overvoltage from power supply • Check external 24 V voltage with voltmeter. • Send unit for repair. Run LED is OFF Hardware error. • Send unit for repair. Internal fuse blown (BC810) External fuse blown (TP857) EPOK LED is OFF when external power is connected Hardware error. External fuse blown (TP857) • Send unit for repair. C1 or C2 LED OFF despite accessing CEX-units CEX-Bus units using no interrupt (for example CI851), no action is needed.Neither R(un) nor F(ault) LEDs are ON The SM810/SM811 board is in the process of being restarted or configured. Allow time for this to finalize. If the condition persists, and no other unit LED on the CEX-Bus is lit: • Check the Log File • Check the CEX-Bus fuse inside the CPU unit. • Initiate a reset signal (INIT) from the CPU unit. • Replace the SM810/SM811 unit. F(ault) LED is ON Unit error. Replace the SM810/SM811 unit. PRIM LED is flashing Unit error. Replace the SM810/SM811 unit. PRIM LED is OFF in single configuration. Unit error. Replace the SM810/SM811 unit. SYNC LED is flashing Upgrade in progress. When the LED is blinking with a symmetric pattern, allow time for this to finalize. If the LED is blinking with a 3 blinks and a pause sequence, the SM811 is ready for acknowledgment of SIL3 hot insert, see SM811 and TP868 on page 278. If the condition persists for a longer time, replace the SM810/SM811 unit.



    2.产      品      展      示      

    微信图片_20230315095822_副本.jpg



    3.公      司      优           主      营      产      品

    微信图片_20230308175114.png



    4.相            产     品      展      示

    TRICONEX.png



    本篇文章出自瑞昌明盛自动化设备有限公司官网,转载请附上此链接:http://www.jiangxidcs.com

    品牌:ABB


    型号:ABB SDCS-CON-4 3ADT313900R1501模块卡件


    质保:一年


    成色:全新/二手


    优势产品ABB、GE、FOXBORO、TRICONEX、BENTLY、A-B、MOTOROLA、HONEYWELL 、SCHNEIDER 

                        WOODWARD、EMERSON、RELIANCE、DEIF、NI、XYVOM


    特点:主营产品各种模块/卡件,控制器,触摸屏,伺服驱动器。


    应用行业:广泛应用于冶金、石油天然气、玻璃制造业、铝业、石油化工、煤矿、造纸印刷、纺织印染、机械、电子制造、汽车制造、烟草、塑胶机械、电力、水利、水处理/环保、市政工程、锅炉供暖、能源、输配电等