GE DS200PCCAG7ACB电源连接板
02-非法数据地址主机发送的数据字段中引用的地址不是PQM允许的地址。03-非法数据值主机传输的数据字段中引用的值不在所选数据地址的范围内。内存映射信息存储在PQM中的数据分为设定值和实际值。设置点可由主计算机读取和写入。实际值只能读取。所有设定值和实际值存储为双字节值。也就是说,每个寄存器地址都是两字节值的地址。地址以十六进制列出。数据值(设定点范围、增量、出厂值)以十进制表示。可自定义内存映射PQM在内存映射中包含用户可定义区域。该区域允许重新映射所有实际值和设定值寄存器的地址。用户可定义区域有两个部分:1。包含120个实际值或设定值寄存器地址的寄存器索引区域(内存映射地址0180H-01F7H)。2.寄存器区域(存储器映射地址0100H-017FH),包含寄存器索引中地址处的数据。
02 - ILLEGAL DATA ADDRESS The address referenced in the data field transmitted by the master is not an allowable address for the PQM. 03 - ILLEGAL DATA VALUE The value referenced in the data field transmitted by the master is not within range for the selected data address. Memory Map Information The data stored in the PQM is grouped as Setpoints and Actual Values. Setpoints can be read and written by a master computer. Actual Values can be read only. All Setpoints and Actual Values are stored as two byte values. That is, each register address is the address of a two byte value. Addresses are listed in hexadecimal. Data values (Setpoint ranges, increments, factory values) are in decimal.ser-definable Memory Map The PQM contains a User Definable area in the memory map. This area allows remapping of the addresses of all Actual Values and Setpoints registers. The User Definable area has two sections: 1. A Register Index area (memory map addresses 0180H-01F7H) that contains 120 Actual Values or Setpoints register addresses. 2. A Register area (memory map addresses 0100H-017FH) that contains the data at the addresses in the Register Index.