您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

HIEE300771R1 HAC319AEV1控制模块,模块卡件

HIEE300771R1 HAC319AEV1控制模块,模块卡件

HIEE300771R1 HAC319AEV1控制模块,模块卡件连接到RX3i CEP001端口的应启用以太网自动协商。RX3i CEP001载波和其他参与设备可以菊花链/线路或星形拓扑连接。小心不要将以太网接口上的两个端口直接或间接连接到同一设备,以形成一个循环网络,除非在一个节点主动设置为介质冗余管理器的情况下启用了介质冗余。支持的网络媒体类型和距离有线基础设施上的PROFINET I/O必须...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIEE300771R1 HAC319AEV1控制模块,模块卡件

    HIEE300771R1 HAC319AEV1控制模块,模块卡件

    连接到RX3i CEP001端口的应启用以太网自动协商。RX3i CEP001载波和其他参与设备可以菊花链/线路或星形拓扑连接。小心不要将以太网接口上的两个端口直接或间接连接到同一设备,以形成一个循环网络,除非在一个节点主动设置为介质冗余管理器的情况下启用了介质冗余。支持的网络媒体类型和距离有线基础设施上的PROFINET I/O必须为100Mbps全双工或更快。该硬件能够以10Mbps的速度运行,但不应用于PROFINET。媒体类型连接器类型波长(nm)媒体类型核心尺寸(μm)模式带宽(MHz–km)最大距离10/100BASE-TX RJ-45-CAT5/CAT5e/CAT6--100 m(328 ft)16.25.11为CEP001分配I/O设备名称,检索输入数据并提供输出数据。然后,它以配置的生产率通过以太网接口与配置的PROFINET IO控制器交换数据。GCG001可以在单个Genius串行总线上管理多达31个Genius I/O设备的通信。GCG001还作为I/O设备运行,由连接的RX3i PROFINET IO控制器(PNC001)控制。因此,当正确配置时,整个Genius总线(包括GCG001本身)对控制PLC(在本例中为RX3i)可见。请注意,GCG001仅与GE PLC PROFINET IO控制器一起运行。PROFINET在以太网上运行。如果以太网或Genius串行总线通信丢失,GCG001将根据各个模块配置管理IO状态。PROFINET和Genius都可以设置为冗余配置。Genius通信网关功能包括:§连接两个RJ-45以太网连接(端口1和2)§支持星形(交换)和线性(菊花链)网络拓扑§支持以太网媒体冗余协议(MRP)§指示以太网状态的LED(ACT和LINK)§连接Genius总线连接(标记为Genius A)。§支持由具有两个GCG001网关的单个Genius总线组成的Genius冗余,一个位于SBA#30,另一个位于SBA#31。§LED指示Genius通信状态(COM)§LED指示模块状态(参考模块标题)§面板安装(典型)。可选安装在RX3i扩展槽中。PACSystems*RX3i系统手册第16节GFK-2314T 2019年9月专用模块805§模块底面(前部)上的电缆固定环§模块底面的24Vdc电源连接器§安全数字(SD)卡槽,可在模块后部访问§固件加载按钮,可在模块后部访问请参阅PACSystems RX3i Genius通信网关用户手册,GFK-2892。16.22.1 LED指示灯:GCG001模块集管中的四个LED指示灯提供GCG001组件状态的视觉指示。POWER(电源)-表示模块有电源。绿色,ON稳定电源良好。OFF电源关闭或不正常。OK(正常)-表示GCG001准备好执行正常模块操作。绿色,ON稳定模块能够执行正常操作。绿色/琥珀色,闪烁模块加载主操作系统琥珀色,ON稳定模块加载引导加载程序操作系统OFF模块出现不可恢复的故障或未通电。FAULT(故障)-表示模块检测到故障。OFF不存在故障。红色,闪烁2Hz DCP设备

    connected to the RX3i CEP001 ports should have Ethernet Auto-negotiation enabled. The RX3i CEP001 Carriers and other participating devices can be connected in a daisy-chain/line, or star topology. CAUTION Do not connect both ports on the Ethernet interface, directly or indirectly, to the same device so as to form a circular network unless Media Redundancy is enabled with one node actively set up as the Media Redundancy Manager. Supported Network Media Types and Distances PROFINET I/O over-wired infrastructure must be 100Mbps full-duplex or faster. The hardware is capable of operating at 10Mbps but should not be used for PROFINET. Media Type Connector Type Wavelength (nm) Media Type Core Size (μm) Modal Bandwidth (MHz – km) Maximum Distance 10/100BASE-TX RJ-45 - CAT5/CAT5e/CAT6 - - 100 m (328 ft) 16.21.5.11 Assigning an I/O Device Name to the CEP001 , retrieving input data and providing output data. It then exchanges that data with its configured PROFINET IO Controller over its Ethernet interfaces at the configured production rate. The GCG001 can manage communications for up to 31 Genius I/O devices on a single Genius Serial Bus. The GCG001 also operates as an I/O Device, controlled by the RX3i PROFINET IO Controller (PNC001) to which is attached. Thus, when correctly configured, the entire Genius Bus, including the GCG001 itself, becomes visible to the controlling PLC (in this case an RX3i). Note that the GCG001 operates only with GE PLC PROFINET IO Controllers. PROFINET operates on an Ethernet network. If the Ethernet network or Genius serial bus communications are lost, the GCG001 manages IO states according to the individual module configurations. Both PROFINET and Genius may be set up in Redundant configurations. Genius Communications Gateway features include: § Attachment of two RJ-45 Ethernet connections (Ports 1 & 2) § Support for both star (switched) and linear (daisy-chained) network topologies § Supports Ethernet Media Redundancy Protocol (MRP) § LEDs to indicate Ethernet status (ACT & LINK) § Attachment Genius bus connections (marked Genius A). § Supports Genius Redundancy consisting of a single Genius bus with two GCG001 Gateways, one at SBA #30 and the other at SBA #31. § LED to indicate Genius Communications Status (COM) § LEDs to indicate module status (refer to module header) § Panel-mount (typical). Optional mounting in RX3i expansion slot. PACSystems* RX3i System Manual Section 16 GFK-2314T Sept. 2019 Special Purpose Modules 805 § Cable tie-down loop on underside of module (at front) § 24Vdc power connector on underside of module § Secure Digital (SD) Card Slot, accessible at rear of module § Firmware load pushbutton, accessible at rear of module Refer to PACSystems RX3i Genius Communications Gateway User Manual, GFK-2892. 16.22.1 LED Indications: GCG001 The four LEDs in the module header provide a visual indication of the GCG001 module status. POWER — indicates the presence of power to the module. Green, ON steady Power supply is good. OFF Power supply is off or not good. OK — indicates GCG001 readiness to perform normal module operations. Green, ON steady Module able to perform normal operations. Green/Amber, blinking Module loading main operating system Amber, ON steady Module loading boot-loader operating system OFF Module has an unrecoverable fault or power is not applied. FAULT — indicates the detection of faults by the module. OFF No faults present. Red, blinking 2Hz DCP Device 

    2022.12.15.jpg

    2022.12.31.jpg

    公司简介_副本.jpg

    手机轮播图2(1)_副本.jpg



    品牌:ABB

    型号:HIEE300771R1 HAC319AEV1 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号