HIEE300885R0001 PPC380AE01备件模块,模块备件

HIEE300885R0001 PPC380AE01备件模块,模块备件

HIEE300885R0001 PPC380AE01备件模块,模块备件它不用于永久连接。注:CEP001载波需要用户提供+24 Vdc电源。16.21.2单个LED的正常操作:CEP001和CEE001 16.22.1电源LED RX3i CEP001载体有两个电源LED,PWR1和PWR2,指示电源是否接通,并且在两个电源对应的范围内。绿色,ON电源以最低指定水平应用OFF电源没有电源或出现故障...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIEE300885R0001 PPC380AE01备件模块,模块备件

    HIEE300885R0001 PPC380AE01备件模块,模块备件

    它不用于永久连接。注:CEP001载波需要用户提供+24 Vdc电源。16.21.2单个LED的正常操作:CEP001和CEE001 16.22.1电源LED RX3i CEP001载体有两个电源LED,PWR1和PWR2,指示电源是否接通,并且在两个电源对应的范围内。绿色,ON电源以最低指定水平应用OFF电源没有电源或出现故障。16.221.2.2 OK LED OK LED指示CEP001载体是否能够正常运行。绿色,ON RX3i CEP001正常琥珀色,ON RX4i CEP001载体或IO模块出现故障琥珀色,闪烁模式致命错误。错误代码之间闪烁一次。快速闪烁的CEP001没有有效的MAC地址OFF CEP001有不可恢复的故障16.21.2连接LED连接LED指示PROFINET连接的状态。绿色,ON至少存在一个PROFINET连接(AR),IO控制器呈琥珀色,闪烁模式致命错误。OK LED®HART®上闪烁的错误代码之间闪烁一次。HART®是美国德克萨斯州奥斯汀市HART通信基金会的注册商标。本文件或本文件引用的任何文件中使用的术语HART均意味着注册商标。PACSystems*RX3i系统手册第16节GFK-2314T 2019年9月专用模块790琥珀色,1Hz闪烁未配置设备名称关闭不存在PROFINET连接(AR)16.21.2.4端口LED RX3i CEP001有两个端口LED,即PRT1和PRT2,指示与两个外部以太网端口相对应的链路速度、链路连接和链路活动。绿色,ON链路已连接,100 Mbps绿色,闪烁端口激活,100 Mbps琥珀色,ON链路连接,10 Mbps琥珀色、闪烁端口激活、10 Mbps琥珀黄色,闪烁模式致命错误。在OK LED熄灭时闪烁的错误代码之间闪烁一次相关的以太网端口未连接到活动链路(可通过配置禁用)注意:多个LED可能以指示特殊情况的模式闪烁,例如请求模块识别。请参阅PACSystems RX3i PROFINET扫描仪IC695CEP001用户手册,GFK-2883。16.21.25电源LED(IC694CEE001)RX3i扩展载体CEE001有一个PWR LED,用于指示RX3i CEP001载体提供的电源是否在范围内。绿色、ON OK琥珀色、ON电源24Vdc和/或5Vdc不在规定范围内关闭无电源16.21.3订购信息IC695CEP001 RX3i CEP001带RJ-45铜以太网接口的载体IC694CEE001 RX3i-CEE001扩展载体16.21.4规格PROFINET支持PROFINET 2.3版A类IO设备RX3i控制器版本要求IC695CPU315/CPU320/CPE302/CPE305/CPE310/CPE330/CRU320,固件v8.50或更高版本的IC69PNC001 PROFINET IO控制器,固件版本2.20或更高的RXi控制器版本要求RXi控制器ICRXICTL000,固件版本7.80或更低版本与CEP001版本2.01兼容,但与CEP001 2.30不兼容。Proficy Machine Edition版本要求8.6版,带有SIM 3或更高版本的PACSystems*RX3i系统手册第16节GFK-2314T 2019年9月专用模块791连接器IC695CEP001:两个RJ-45 10/100Base TX插座IC694CEE001:无USB连接器(用于固件升级)IC695CEP001:一个Micro-B连接器。符合USB 2.0标准,在设备模式IC694CEE001下全速(12 MHz)运行:无PNS状态和控制位32输入状态位和IP地址1;支持无类别域间路由(CIDR)MAC地址数三;每个外部端口一个,内部端口一个。外部MAC地址仅用于专用以太网协议,如MRP或LLDP。I/O站最大限制每个站的I/O模块数量IC695CEP001:一个IC695CEP001+IC694CEE001:每个站两个I/O数据1024字节总512字节输入数据512字节输出数据配置与作为RX3i高速I/O LAN系统一部分的PACSystems RX3i PROFINET控制器模块一起使用时,使用Proficy Machine Edition配置。V2.3 GSDML文件可用于导入第三方工具。有关产品标准和一般规范,请参阅附录A.16.21.5快速入门:CEP001和CEE001

    It is not intended for permanent connection. Note: The CEP001 Carrier requires a user-supplied +24 Vdc power source. 16.21.2 Normal Operation of Individual LEDs: CEP001 & CEE001 16.21.2.1 Power LEDs The RX3i CEP001 Carrier has two Power LEDs, PWR1 and PWR2 that indicate whether the power is applied and is within range corresponding to the two power sources. Green, ON Power is applied at the minimum specified level OFF The power supply does not have power or has failed. 16.21.2.2 OK LED The OK LED indicates whether the CEP001 Carrier is able to perform normal operation. Green, ON RX3i CEP001 is OK Amber, ON Either the RX3i CEP001 Carrier or IO module has a fault Amber, blink pattern Fatal error. Flashes once between error codes. Fast blinking CEP001 has no valid MAC addresses OFF CEP001 has an unrecoverable fault 16.21.2.3 Connect LED The CONN LED indicates the status of PROFINET connections. Green, ON At least one PROFINET connection (AR) exists with an IO-Controller Amber, blink pattern Fatal error. Flashes once between error codes blinked on the OK LED ® HART® is a registered trademark of the HART Communication Foundation of Austin, Texas USA. Any use of the term HART hereafter in this document, or any document referenced by this document, implies the registered trademark. PACSystems* RX3i System Manual Section 16 GFK-2314T Sept. 2019 Special Purpose Modules 790 Amber, blink in 1Hz No device name configured OFF No PROFINET connection (AR) exists 16.21.2.4 Port LEDs The RX3i CEP001 has two Port LEDs, PRT1 and PRT2 that indicate link speed, link connection and link activity corresponding to the two external Ethernet ports. Green, ON Link connected, 100 Mbps Green, blinking Port active, 100 Mbps Amber, ON Link connected, 10 Mbps Amber, blinking Port active, 10 Mbps Amber, blink pattern Fatal error. Flashes once between error codes blinked on the OK LED OFF The associated Ethernet port is not connected to an active link (can be disabled by configuration) Note: Multiple LEDs can blink in patterns that indicate special conditions, such as a request for module identification. Refer to PACSystems RX3i PROFINET Scanner IC695CEP001 User Manual, GFK-2883. 16.21.2.5 Power LED (IC694CEE001) The RX3i Expansion Carrier CEE001 has one PWR LED to indicate whether the power provided by the RX3i CEP001 Carrier is within range. Green, ON OK Amber, ON Power 24Vdc and/or 5Vdc is not in specified range OFF No power 16.21.3 Ordering Information IC695CEP001 RX3i CEP001 Carrier with RJ-45 Copper Ethernet Interface IC694CEE001 RX3i CEE001 Expansion Carrier 16.21.4 Specifications PROFINET support PROFINET Version 2.3 Class A IO-Device RX3i Controller version required IC695CPU315/CPU320/CPE302/CPE305/CPE310/CPE330/CRU320, firmware v8.50 or later IC69PNC001 PROFINET IO-controller with firmware version 2.20 or later RXi Controller version required RXi Controller, ICRXICTL000, with firmware version 7.80 or later is compatible with CEP001 up to version 2.01, but is not compatible with CEP001 version 2.30. Proficy Machine Edition version required Version 8.6 with SIM 3 or later PACSystems* RX3i System Manual Section 16 GFK-2314T Sept. 2019 Special Purpose Modules 791 connectors IC695CEP001: Two RJ-45 10/100Base-TX receptacles IC694CEE001: None USB connector (for firmware upgrades) IC695CEP001: One Micro-B connector. USB 2.0 compliant running at full-speed (12 MHz) in device mode IC694CEE001: None PNS status and control bits 32 input status bits and IP addresses One; supports Classless Inter-Domain Routing (CIDR) Number of MAC addresses Three; one per external port and one internal. External MAC addresses are only used for specialized Ethernet protocols such as MRP or LLDP. I/O station maximum limits Number of I/O modules per station IC695CEP001: One IC695CEP001 with IC694CEE001: Two I/O data per station 1024 bytes total 512 bytes of input data 512 bytes of output data Configuration Configured using Proficy Machine Edition when used with a PACSystems RX3i PROFINET Controller module as part of an RX3i High-speed I/O LAN system. V2.3 GSDML file available for import into 3rd-Party tools. For product standards and general specifications, refer to Appendix A. 16.21.5 Quick Start: CEP001 & CEE001 

    2022.12.14.jpg

    2023.1.5.jpg

    fa405aeea632aa6912154382925a28b_副本.jpg

    手机轮播图2(1)_副本.jpg



    品牌:ABB

    型号:HIEE300885R0001 PPC380AE01 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号