您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

HIEE300890R0001 UAC383AE01控制器模块

HIEE300890R0001 UAC383AE01控制器模块

HIEE300890R0001 UAC383AE01控制器模块l协议支持Modbus RTU从站、SNP、串行I/O、,Modbus RTU Master by application“C”block Backplane双背板总线支持:RX3i PCI和90-30型串行PCI兼容系统设计为符合PCI 2.2标准PACSystems*RX3i系统手册第16节GFK-2314T 2019年9月特殊用途...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIEE300890R0001 UAC383AE01控制器模块

    HIEE300890R0001 UAC383AE01控制器模块

    l协议支持Modbus RTU从站、SNP、串行I/O、,Modbus RTU Master by application“C”block Backplane双背板总线支持:RX3i PCI和90-30型串行PCI兼容系统设计为符合PCI 2.2标准PACSystems*RX3i系统手册第16节GFK-2314T 2019年9月特殊用途模块768端口RS-232串行端口RS-485串行端口外部隔离。(有关详细信息,请参阅RS-485端口隔离器、IC690ACC903、GFK-1663。)16.16.6 NIU001 PLUS与NIU001经典比较功能NIU001 Classic NIU001 PLUS处理器Celeron 300 MHz Atom 510、1.1 GHz实时时钟电池不支持IC690ACC001内存备份和实时时钟电池IC698ACC701不支持嵌入式通信RS-232、RS-485 RS-232、,RS-485电源要求+3.3Vdc:1.25安培标称+5.0 Vdc:1.0安培标称+3.3Vcc:0.52安培标称+5.0Vdc:0.95安培标称性能与CPU310相同。有关性能数据,请参阅PACSystems RX3i和RSTi EP CPU参考手册GFK-2222。注意:该处理器已从300MHz赛扬升级为1.1GHz Atom处理器。与NIU001 Classic相比,性能有许多相关变化。有关性能数据,请参阅PACSystems RX3i和RSTi EP CPU参考手册GFK-2222R或更高版本。布尔执行速度,通常每1000条布尔指令0.181毫秒每1000条逻辑指令0.072毫秒电池和开关位置有关详细信息,请参阅PACSystems RX3i以太网网络接口单元用户手册GFK-2439。有关详细信息,请参阅PACSystems RX3i以太网网络接口单元用户手册,GFK-2439 16.16.7端口PACSystems*RX3i系统手册第16节GFK-2314T 2019年9月专用模块769 NIU PLUS有两个独立的板载串行端口,可通过模块前面的连接器访问。这些端口为外部设备提供串行接口。端口1(COM1)是一个DCE端口,它允许简单的直通电缆与标准AT型RS-232端口连接。它有一个带有标准引脚输出的9针凹形D-sub连接器。端口2(COM2)是一个与RS-485兼容的DCE端口。端口2有一个15针内螺纹D-sub连接器。以太网NIU没有以太网端口。以太网通信由位于I/O站中的一个或多个以太网发射机模块(本章前面所述)提供。16.16.7.1支持的协议端口1端口2 RTU(从设备)是是SNP从设备是串行I/O94是是固件升级ENIU处于停止/无I/O模式消息模式(C运行时专用模块770图404:IC695PBM300 16.17.1功能IC695PBM300模块提供以下功能:▪ 支持多达125个PROFIBUS-DP从站▪ 每个从属设备最多支持244字节的输入数据和244字节的输出数据▪ 最多支持3584字节输入数据和3584字节输出数据▪ 支持所有标准数据速率▪ 支持同步和冻结模式▪ 支持DP-V1读、写和报警消息▪ PROFIBUS兼容模块和网络状态指示灯此模块必须位于RX3i通用背板中。模块支持插入和取出通电的RX3i通用背板。参见第2.6.4.1节热插拔。有关此模块的更多信息,请参阅PACSystems RX3i PROFIBUS模块用户手册GFK-2301。16.17.2 PROFIBUS主模块控制和指示灯16.17.2.1网络连接器PROFIBUS主模块有一个9针sub-D连接器,用于连接总线电缆。有关引脚分配、段长度、电缆类型和终端要求,请参阅RX3i PACSystems PROFIBUS模块用户手册GFK-2301

    l Protocols supported Modbus RTU Slave, SNP, Serial I/O, Modbus RTU Master by application “C” block Backplane Dual backplane bus support: RX3i PCI and 90-30-style serial PCI compatibility System designed to be electrically compliant with PCI 2.2 standard PACSystems* RX3i System Manual Section 16 GFK-2314T Sept. 2019 Special Purpose Modules 768 Ports RS-232 Serial Port RS-485 Serial Port External isolation recommended. (For details, refer to RS-485 Port Isolator, IC690ACC903, GFK-1663.) 16.16.6 NIU001 PLUS vs. NIU001 Classic Comparison Feature NIU001 Classic NIU001 PLUS Processor Celeron 300 MHz Atom 510, 1.1 GHz Real Time Clock Battery Not supported IC690ACC001 Memory Backup and Real Time Clock Battery IC698ACC701 Not supported Embedded communications RS-232, RS-485 RS-232, RS-485 Power requirements +3.3Vdc: 1.25 Amps nominal +5.0 Vdc: 1.0 Amps nominal +3.3Vdc: 0.52 Amps nominal +5.0 Vdc: 0.95 Amps nominal Performance Same as CPU310. For performance data, refer to the PACSystems RX3i and RSTi-EP CPU Reference Manual, GFK-2222. Note: The processor has been upgraded from a 300MHz Celeron to a 1.1 GHz Atom processor. There have been many associated changes to the performance compared to the NIU001 Classic. For performance data, refer to the PACSystems RX3i and RSTi-EP CPU Reference Manual, GFK-2222R or later. Boolean execution speed, typical 0.181 ms per 1000 Boolean instructions 0.072 ms per 1000 Boolean instructions Battery and switch locations For details, refer to the PACSystems RX3i Ethernet Network Interface Unit User’s Manual, GFK-2439. For details, refer to the PACSystems RX3i Ethernet Network Interface Unit User’s Manual, GFK-2439 16.16.7 Ports PACSystems* RX3i System Manual Section 16 GFK-2314T Sept. 2019 Special Purpose Modules 769 The NIU PLUS has two independent, on-board serial ports, accessed by connectors on the front of the module. These ports provide serial interfaces to external devices. Port 1 (COM1) is a DCE port that allows a simple straight-through cable to connect with a standard AT-style RS-232 port. It has a 9-pin, female, D-sub connector with a standard pin out. Port 2 (COM2) is a DCE port that is RS-485 compatible. Port 2 has a 15-pin, female D-sub connector. The Ethernet NIU does not have an Ethernet port. Ethernet communications are provided by one or more Ethernet Transmitter Modules (described previously in this chapter) located in the I/O Station. 16.16.7.1 Protocols Supported Protocol Port 1 Port 2 RTU (slave) Yes Yes SNP Slave Yes Yes Serial I/O94 Yes Yes Firmware Upgrade ENIU in STOP/No I/O mode Message Mode (C Runtime Special Purpose Modules 770 Figure 404: IC695PBM300 16.17.1 Features The IC695PBM300 module provides the following features: ▪ supports up to 125 PROFIBUS-DP slaves ▪ supports up to 244 bytes of input data and 244 bytes of output data per slave ▪ Supports up to 3,584 bytes of input data and 3,584 bytes of output data total ▪ Supports all standard data rates ▪ Supports Sync and Freeze modes ▪ Supports DP-V1 Read, Write and Alarm messages ▪ PROFIBUS-compliant Module and Network Status LEDs This module must be located in an RX3i Universal Backplane. Module supports insertion into and removal from an RX3i Universal Backplane which is under power. Refer to Hot Insertion and Removal, Section 2.6.4.1. For more information about this module, please refer to the PACSystems RX3i PROFIBUS Module User’s Manual, GFK-2301. 16.17.2 PROFIBUS Master Module Controls and Indicators 16.17.2.1 Network Connector The PROFIBUS Master module has a 9-pin sub-D connector for attaching the bus cable. For pin assignments, segment length, cable type and termination requirements, refer to the RX3i PACSystems PROFIBUS Modules User’s Manual, GFK-2301

    2022.12.31.jpg

    2022.12.14.jpg

    fa405aeea632aa6912154382925a28b_副本.jpg

    手机轮播图2(1)_副本.jpg



    品牌:ABB

    型号:HIEE300890R0001 UAC383AE01 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号