您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

IS200AEGIH1BBR2自动化模块备件

IS200AEGIH1BBR2自动化模块备件

IS200AEGIH1BBR2自动化模块备件示例:感应式接近探头或霍尔效应齿轮齿传感器可用于感应Auxiliary2、Alarm&Auxiliary 2&Auxillary 3、Alarm&auxiliary 3、Auxiliay 2、Auxillay 2和Auxilia 3、Aussiliary 3通用开关A报警延迟:5.0 s范围:0.1至5000.0秒,步骤0.1通用开关A事件:关闭范围:打...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

IS200AEGIH1BBR2自动化模块备件

    IS200AEGIH1BBR2自动化模块备件

    示例:感应式接近探头或霍尔效应齿轮齿传感器可用于感应Auxiliary2、Alarm&Auxiliary 2&Auxillary 3、Alarm&auxiliary 3、Auxiliay 2、Auxillay 2和Auxilia 3、Aussiliary 3通用开关A报警延迟:5.0 s范围:0.1至5000.0秒,步骤0.1通用开关A事件:关闭范围:打开、关闭通用开关A跳闸:关闭范围,未锁定分配跳闸继电器:跳闸范围:跳闸、跳闸和辅助2、跳闸和辅2和辅助3、跳闸和备用3通用开关A跳闸延迟:5.0 s范围:0.1至5000.0秒。,step 0.1 MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESTAGE ESCAPE MESSAGE ESC APE MESPAGE ESCAPE-ESCAPE 4-24 469电机管理继电器GE Power Management 4.5 S4输出继电器4设定点编程4 4.5 S4输出继电保护4.5.1描述六个输出继电器中的五个始终是非故障安全的,R6服务始终是故障安全的。作为故障保护,R6继电器将正常通电,并在需要操作时断电。当469的控制电源丢失时,它也将断电,因此处于其操作状态。所有其他非故障保护继电器将正常断电,并在需要操作时通电。显然,当469失去控制电源时,输出继电器必须断电,因此,它们将处于非操作状态。拉出箱中的短杆确保469拉出时不会发生跳闸或报警。然而,R6服务输出将指示469已被抽出。4.5.2继电器重置模式a)重置469如果导致跳闸或警报的条件不再存在,则可随时重置锁定跳闸或警报。一旦条件不再存在,未锁定跳闸和报警将自动重置。如果可以重置任何条件,则“重置可能”LED将点亮。锁定时间到期且跳闸复位后,所有块启动功能自动复位。其他继电器可编程为All reset(所有重置),这允许从前键盘或远程重置开关输入或通信端口进行重置。可选地,继电器1至6可编程为通过“仅远程重置”(通过远程重置开关输入或通信端口)或“仅键盘重置”(仅通过继电器键盘重置)进行重置。不得将跳闸或报警元件分配给两个输出继电器,其中一个仅限远程复位,另一个仅为键盘复位。如果发生这种情况,跳闸或报警将无法恢复。b) 示例:严重跳闸(如短路和接地故障)可分配给R2,因此只能通过复位。远程重置终端(D18和D23)或通信端口。远程重置终端应连接到钥匙开关,以便只有授权人员才能重置此类关键跳闸。•仅将短路和接地故障分配给R2•将R2辅助编程为“仅远程复位”❙ 继电器复位模式❙ [输入]更多R1跳闸:所有重置范围:所有重置,仅远程重置,仅键盘重置R2辅助:所有重置量程:所有重置、仅远程重置、仅键盘重置R3辅助:所有复位

    EXAMPLE An inductive proximity probe or hall effect gear tooth sensor may be used to sense the key on the Auxiliary2, Alarm & Aux2 & Aux3, Alarm & Auxiliary3, Auxiliary2, Aux2 & Aux3, Auxiliary3 GENERAL SWITCH A ALARM DELAY: 5.0 s Range: 0.1 to 5000.0 sec., step 0.1 GENERAL SWITCH A EVENTS: Off Range: On, Off GENERAL SWITCH A TRIP: Off Range: Off, Latched, Unlatched ASSIGN TRIP RELAYS: Trip Range: Trip, Trip & Auxiliary2, Trip & Aux2 & Aux3, Trip & Auxiliary3 GENERAL SWITCH A TRIP DELAY: 5.0 s Range: 0.1 to 5000.0 sec., step 0.1 MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE 4-24 469 Motor Management Relay GE Power Management 4.5 S4 OUTPUT RELAYS 4 SETPOINT PROGRAMMING 4 4.5 S4 OUTPUT RELAYS 4.5.1 DESCRIPTION Five of the six output relays are always non-failsafe, R6 Service is always failsafe. As failsafe, R6 relay will be energized normally and de-energize when called upon to operate. It will also de-energize when control power to the 469 is lost and therefore, be in its operated state. All other relays, being non-failsafe, will be de-energized normally and energize when called upon to operate. Obviously, when control power is lost to the 469, the output relays must be de-energized and therefore, they will be in their non-operated state. Shorting bars in the drawout case ensure that when the 469 is drawn out, no trip or alarm occurs. The R6 Service output will however indicate that the 469 has been drawn out. 4.5.2 RELAY RESET MODE a) RESETTING THE 469 A latched trip or alarm may be reset at any time, providing that the condition that caused the trip or alarm is no longer present. Unlatched trips and alarms will reset automatically once the condition is no longer present. If any condition may be reset, the Reset Possible LED will be lit. All Block Start features reset automatically when the lockout time has expired and the trip has been reset. The other relays may be programmed to All Resets which allows reset from the front keypad or the remote reset switch input or the communications port. Optionally, relays 1 through 6 may be programmed to reset by the "Remote Reset Only" (by the remote reset switch input or the communications port) or "Keypad Reset Only" (reset only by relay keypad). NO trip or alarm element must EVER be assigned to two output relays where one is Remote Reset Only and the other is Keypad Reset Only. The trip or alarm will be unresettable if this occurs. b) EXAMPLE Serious trips such as Short Circuit and Ground Fault may be assigned to R2 so that they may only be reset via. the remote reset terminals (D18 and D23) or the communication port. The remote reset terminals should be connected to a keyswitch so that only authorized personnel could reset such a critical trip. • Assign only Short Circuit and Ground Fault to R2 • Program R2 AUXILIARY to "Remote Reset Only" ❙ RELAY RESET MODE ❙ [ENTER] for more R1 TRIP: All Resets Range: All Resets, Remote Reset Only, Keypad Reset Only R2 AUXILIARY: All Resets Range: All Resets, Remote Reset Only, Keypad Reset Only R3 AUXILIARY: All Resets

    2022.12.14.jpg

    FOXBORO H92A0K9V0H00.jpg

    23.jpg

    20.jpg



    品牌: GE

    型号:IS200AEGIH1BBR2 

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号