IS200ESELH1AAA工控备件,工控备件模块
离散混合模块通过将输入和输出组合在一个紧凑的模块中提供灵活性。模块需要载体底座(IC200CHSxxx)。离散混合I/O模块产品编号IC200MDD847 IC200MDD848 IC200MDD8409产品名称VersaMax离散混合模块VersaMax分立混合模块Versa max分立混合模件240 VAC输入8点/输出继电器120 VAC输入8个点/输出120 VAC输入隔离8点/输出2.0A隔离8点最大浪涌输入和输出响应1个交流周期最小值和2个交流周期1个周期/2周期和1周期/2周期和时间-开/关(ms)(取决于Hz)和10.0关<1/2周期/<1/2周期10/10保护内部保险丝或缓冲器缓冲器和MOV(每个输出)内部保险丝或缓冲打开状态电流4 mA最小5 mA最小关闭状态电流1.5 mA 2.5 mA 2.5 mA外部电源0-125 VDC,5/24/125 VDC;0-125 VDC,5/24/125 VDC终端指示器每个点一个LED显示单个LED每个点显示单个LED每点一个显示单个点开/关状态(逻辑侧);OK LED点开/关状态(逻辑侧);OK LED点开/关状态(逻辑侧);OK LED指示灯指示存在背板电源指示存在背板功率指示存在背板电压尺寸(宽x高x深)110mm(4.3in)x 66.8mm(2.63in)x 50mm 110mm(4.3 in)x 6.68mm(2.63 in)x 50 mm 110mm(4.0 in)x 66 mm(2.63英寸)x 50mm(1.956 in),t包括(1.956英寸)的高度,t包括1.956英寸的高度,t包括托架或配合连接器的高度(载体或配套连接器Artisan Technology Group-Quality Instrumentation…Guaranteed VersaMax GE Fanuc控制器和I/O解决方案147离散混合模块通过将输入和输出组合在一个紧凑的模块中提供灵活性。离散输入模块从输入设备(如传感器、按钮和开关)接收信号,这些输入设备可以有两种状态:打开或关闭、打开或关闭。离散输出模块向接触器、指示灯和插入式继电器等设备发送控制信号,这些设备也可以有两种状态。离散混合模块通过将输入和输出组合在一个紧凑的模块中提供灵活性。模块需要载体底座(IC200CHSxxx)。离散混合输入/输出模块IC200MDD850 IC200MDD851产品名称VersaMax离散混合模块240 VAC输入VersaMax分立混合模块5/12 VDC输入隔离4点/输出继电器关闭保护内部保险丝或缓冲器内部保险丝或缓冲器打开状态电流最小值为4 mA最小值为1.45mA关闭状态电流1.5 mA 0至0.7 mA外部电源+10.2至+30 VDC,+12/24 VDC标称输入阻抗38.5千欧(无功),60 Hz,典型值;2.4kΩ,典型@12 VDC 46.3 kΩ(无功),50 Hz,典型负载电流每点最小10 mA;30 VDC时,5-265 VAC 0.5安培时为2.0 A(电阻);(电阻式)指示器每个点一个LED显示单个点开/关状态每个点一LED显示单个点通/关状态逻辑侧);OK LED指示背板电源存在(逻辑侧);OK(正常)LED指示存在背板电源尺寸包括载体或配合连接器的高度t包括载体或配套连接器的高度Artisan Technology Group-Quality Instrumentation。。。保证VersaMax 148 GE Fanuc控制器和I/O解决方案离散输入模块接收来自传感器、按钮和开关等输入设备的信号,这些输入设备可以有两种状态:打开或关闭、打开或关闭。模块需要一个载波离散输入模块IC200MDL140 IC200MDL141 IC200MDL143产品名称VersaMax离散输入模块VersaMax分立输入模块Versa Max分立输入模件120 VAC,8点240 VAC,8个点120 VAC隔离,8点点数888信道到信道隔离是输入和输出响应时间-开/关(ms)
Discrete mixed modules provide flexibility by combining inputs and outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx). Discrete Mixed I/O Modules Product Number IC200MDD847 IC200MDD848 IC200MDD849 Product Name VersaMax Discrete Mixed Modules VersaMax Discrete Mixed Modules VersaMax Discrete Mixed Modules 240 VAC Input 8 points/Output Relay 120 VAC Input 8 points/Output 120 VAC Input Isolated 8 points/Output 2.0A Isolated 8 points max inrush Input and Output Response 1 AC cycle minimum and 2 AC cycle 1 cycle/2 cycle and 1 cycle/2 cycle and Time- On/Off(ms) (Hz dependent) and 10.0 OFF <1/2 cycle/<1/2 cycle 10/10 Protection internal fuses or snubbers Snubber and MOVs (each output) internal fuses or snubbers On State Current 4 mA minimum 5 mA minimum 5 mA minimum Off State Current 1.5 mA 2.5 mA 2.5 mA External Power Supply 0-125 VDC, 5/24/125 VDC minal; 0-125 VDC, 5/24/125 VDC minal Indicators One LED per point shows individual One LED per point shows individual One LED per point shows individual point on/off state (logic side); OK LED point on/off state (logic side); OK LED point on/off state (logic side); OK LED indicates backplane power is present indicates backplane power is present indicates backplane power is present Dimensions (W x H x D) 110mm (4.3in) x 66.8mm (2.63in) x 50mm 110mm (4.3in) x 66.8mm (2.63in) x 50mm 110mm (4.3in) x 66.8mm (2.63in) x 50mm (1.956 in), t including the height of (1.956 in), t including the height of 1.956 in), t including the height of the carrier or the mating connectors the carrier or the mating connectors (the carrier or the mating connectors Artisan Techlogy Group - Quality Instrumentation ... Guaranteed VersaMax GE Fanuc Controller and I/O Solutions 147 Discrete mixed modules provide flexibility by combining inputs and outputs in a single, compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules send control signals to devices such as contactors, indicator lamps, and interposing relays that can also have two states. Discrete mixed modules provide flexibility by combining inputs and outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx). Discrete Mixed I/O Modules IC200MDD850 IC200MDD851 Product Name VersaMax Discrete Mixed Modules 240 VAC Input VersaMax Discrete Mixed Modules 5/12 VDC Input Isolated 4 points/Output Relay OFF Protection internal fuses or snubbers internal fuses or snubbers On State Current 4 mA minimum 1.45mA minimum Off State Current 1.5 mA 0 to 0.7 mA External Power Supply +10.2 to +30 VDC, +12/24 VDC minal Input Impedance 38.5 kOhms (reactive) at 60 Hz, typical; 2.4kOhms typical @ 12 VDC 46.3 kOhms (reactive) at 50 Hz, typical Load Current 10 mA per point minimum; 2.0 A for 5-265 VAC 0.5 Amps at 30 VDC (resistive); (resistive) Indicators One LED per point shows individual point on/off state One LED per point shows individual point on/off state logic side); OK LED indicates backplane power is present (logic side); OK LED indicates backplane power is present Dimensions including the height of the carrier or the mating connectors t including the height of the carrier or the mating connectors Artisan Techlogy Group - Quality Instrumentation ... Guaranteed VersaMax 148 GE Fanuc Controller and I/O Solutions Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Modules require a carrier Discrete Input Modules IC200MDL140 IC200MDL141 IC200MDL143 Product Name VersaMax Discrete Input Module VersaMax Discrete Input Module VersaMax Discrete Input Module 120 VAC, 8 points 240 VAC, 8 points 120 VAC Isolated, 8 points Number of Points 888 Channel to Channel Isolation Yes Input and Output Response Time- On/Off (ms)