IS200HFPAG1A DCS工控模块备件
状态指示器:模块状态通过、故障、负载、活动状态指示器:现场警报1负载(每个点1个)系统到现场隔离1500 VDC最小值点监控可编程每个点短路/开路检测阈值可编程每个监控点输出诊断故障覆盖率2:最大输出切换率每60毫秒诊断故障持续时间最多2毫秒,200μs典型导通状态电压降:在背板上<0.25 VDC典型@250mA<1.7 VDC@1.7A导通状态压降:带外部终端,10英尺电缆<1.25 VDC典型@250 mA<4.7 VDC@1.7B导通状态:带外部端接,99英尺电缆<2.25 VDC典型@250mA<6.7 VDC@1.7A感应反冲保护(反EMF)输出开关为自保护数字输出模块117 Tricon v9–v10系统规划和安装指南注3625可安装在已升级至v10.2.x或更高版本的低密度系统中。有关更多信息,请参阅Tricon v9–v10系统现场终端指南中的附录I“低密度机箱I/O模块兼容性”。32点继电器输出模块本图为3636R和3636T型的简化示意图,它们是非三重继电器输出模块。图48 3636R和3636T简化示意图1。必须向所有点供电,包括非公用面板上未使用的点。2.最大输出切换率可实现I/O诊断的正确操作和所有正常可检测故障的检测。总线Xcvr点寄存器总线Xcvr点寄存器总线Xcvr点寄存器环回检测器/隔离器A B C跳闸I/O总线智能I/O控制器(S)现场电路典型点(32)–表决输出驱动电路+V+V*所有输出开关均电隔离。*NO ContactµProcµProc 118第2章Tricon v9–v10系统的系统组件规划和安装指南此图显示了3636R和3636T型号的前面板。图49 3636R和3636T前面板注意:3636R型和3636T型模块不会为主模块和备用模块设置点LED。只有主模块将断言点LED。银蓝色条纹继电器输出3636R 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19 20 21 23 24 26 27 29 30 31 32 PASS FAULT ACTIVE银蓝色条纹中继器输出3636T 1 2 3 5 6 8 9 11 13 14 16 17 19 20 22 23 24 25 27 28 29 30 32 PASS FAIULT ACTIVED数字输出模块119 Tricon v9–v10系统3636R和3636T规划和安装指南技术规格本表列出了3636R和3636T型非三联继电器输出模块的技术规格。点隔离因型号而异:3636R型号为1500 VDC;3636T型为2500 VDC。切换功率切换无功负载时,应将输出的切换功率降到最大值的25%,即直流应用的37.5瓦。当切换白炽灯时,涌入电流可以是灯的额定额定负载电流的10至15倍。有关涌入幅度和持续时间的详细规范,请联系灯具制造商。在计算所需的输出开关功率时,必须使用涌入电流。表44 3636R和3636T规格特性规格输出触点NO,常开颜色代码银蓝色输出点32个,非公共电压范围155 VAC/VDC,最大电流负载2安培最大开关功率,电阻见第119页2000 VA,最大150瓦最大输出循环率<30次/秒最大额定负载下的预期寿命>10000次/输出保险丝1个,2.5安培快速动作
tatus indicator: Module status Pass, Fault, Load, Active Status indicator: Field alarm1 Load (1 per point) System-to-field isolation 1500 VDC minimum Point supervision Can be programmed per point Short/Open circuit detection threshold Programmable per supervised point Output diagnostic fault coverage2: Maximum output toggle rate Every 60 ms Diagnostic glitch duration 2 ms maximum, 200 μs typical On-state voltage drop: At backplane < 0.25 VDC typical @ 250mA < 1.7 VDC @ 1.7A On-state voltage drop: With external termination, 10-foot cable < 1.25 VDC typical @ 250mA < 4.7 VDC @ 1.7A On-state voltage drop: With external termination, 99-foot cable < 2.25 VDC typical @ 250mA < 6.7 VDC @ 1.7A Inductive kick-back protection (reverse EMF) Output switches are self-protected Digital Output Modules 117 Planning and Installation Guide for Tricon v9–v10 Systems Note The 3625 can be installed in low-density systems that have been upgraded to v10.2.x or later. For more information, see Appendix I, Low-Density Chassis I/O Module Compatibility in the Field Terminations Guide for Tricon v9–v10 Systems. 32-Point Relay Output Modules This figure is a simplified schematic for models 3636R and 3636T, which are non-triplicated Relay Output Modules. Figure 48 3636R and 3636T Simplified Schematic 1. Power must be supplied to all points, including unused points on non-commoned panels. 2. The maximum output toggle rate enables proper operation of I/O diagnostics and detection of all normally detectable faults. Bus Xcvr Point Register Bus Xcvr Point Register Bus Xcvr Point Register Loopback Detector/ Isolator A B C TRIPLICATED I/O BUS INTELLIGENT I/O CONTROLLER(S) FIELD CIRCUITRY TYPICAL POINT (32) – Voted Output Drive Circuitry +V +V * All output switches are galvanically isolated. * NO Contact µProc µProc µProc 118 Chapter 2 System Components Planning and Installation Guide for Tricon v9–v10 Systems This figure shows the front panels of models 3636R and 3636T. Figure 49 3636R and 3636T Front Panels Note The Model 3636R and 3636T modules will not assert point LEDs for both primary and spare modules. Only the primary module will assert point LEDs. Silver Blue Stripe RELAY OUTPUT 3636R 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 PASS FAULT ACTIVE Silver Blue Stripe RELAY OUTPUT 3636T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 PASS FAULT ACTIVE Digital Output Modules 119 Planning and Installation Guide for Tricon v9–v10 Systems 3636R and 3636T Specifications This table lists the specifications for models 3636R and 3636T, which are Non-Triplicated Relay Output Modules. Point isolation varies by model: model 3636R is 1,500 VDC; model 3636T is 2,500 VDC. Switching Power When switching reactive loads, you should de-rate the switching power of the outputs to 25 percent of maximum, which is 37.5 watts for DC applications. When switching incandescent lamps, the inrush current can be 10 to 15 times the rated nominal load current of the lamp. For detailed specifications regarding inrush amplitude and duration, contact the lamp manufacturer. The inrush current must be used when calculating the required output switching power. Table 44 3636R and 3636T Specifications Feature Specification Output contact NO, normally open Color code Silver blue Number of output points 32, non-commoned Voltage range 155 VAC/VDC, maximum Current load 2 amps maximum Switching power, resistive See Switching Power on page 119 2000 VA, 150 watts maximum Maximum output cycle rate < 30 cycles per second Expected life at maximum rated load > 10,000 cycles Fuses 1 per output, 2.5 amps fast-acting