您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

IS200ISBAH1A输出卡件,DCS模块卡件

IS200ISBAH1A输出卡件,DCS模块卡件

IS200ISBAH1A输出卡件,DCS模块卡件警告:如果超过某个信道的共模电压范围,Triconex不能保证模块的正常运行和其他信道的准确性。表13 3701模拟输入规格特性规格颜色代码浅黄色输入信号数量32差分,DC耦合输入更新率55 ms分辨率12位精度<0-60C FSR的0.15%输入电阻(负载)30 MΩ(DC),断电时最小输入电阻30 kΩ(DC,典型共模抑制(典型)-80 d...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

IS200ISBAH1A输出卡件,DCS模块卡件

    IS200ISBAH1A输出卡件,DCS模块卡件

    警告:如果超过某个信道的共模电压范围,Triconex不能保证模块的正常运行和其他信道的准确性。表13 3701模拟输入规格特性规格颜色代码浅黄色输入信号数量32差分,DC耦合输入更新率55 ms分辨率12位精度<0°-60°C FSR的0.15%输入电阻(负载)30 MΩ(DC),断电时最小输入电阻30 kΩ(DC,典型共模抑制(典型)-80 dB(DC-100 Hz)共模电压范围(见警告)-12V至+12V峰值信道到信道隔离200 kΩ,典型正常模式抑制-3 dB@8 Hz-17 dB@60 Hz-23 dB@120 Hz输入电压范围0至10 V逻辑功率<10瓦输入超范围保护150 VDC连续,115 VA连续输入电流范围0至20 mA,带500Ω分流电阻器模块状态指示灯通过、故障、激活输入诊断故障范围1最小输入变化输入变化采样周期最小误比较周期1。快速或连续变化的输入可能会导致错误比较读数,因为三个通道的测量值可能相差满量程的0.5%以上,这可能会导致故障被宣布为错误。如果输入读数至少相差满量程的2%,并且至少持续40个输入样本,则故障概率增加。满量程1次扫描的2%或200 ms(以较大者为准)40个样本52第2章Tricon v9–v10系统3721规格的系统组件规划和安装指南本节包括3721型的规格,该型号为TMR模拟输入模块,电压范围为0至5 VDC或-5至+5 VDC。3721模块只能安装在Tricon v10.2及更高版本的系统中。注意:3721可以安装在已升级到v10.2.x或更高版本的低密度系统中。有关更多信息,请参阅Tricon v9–v10系统现场终端指南中的附录I“低密度机箱I/O模块兼容性”。表14 3721模拟输入规格特性规格颜色代码黄色输入信号数量32差分,DC耦合输入更新率10 ms分辨率12位或14位可编程精度<0°C至60°C FSR的0.15%输入电阻(负载)10 MΩ(DC),断电时最小输入电阻140 kΩ(DC,典型共模抑制(典型)-85 dB(DC-100 Hz)共模电压范围-12V至+12V峰值信道到信道隔离420 kΩ,典型正常模式抑制-23 Hz时为3 dB,60 Hz时为8 dB,120 Hz时为14 dB输入电压范围0至5或-5至5 VDC输入超范围测量+6%,-5.3至+5.3 VDC逻辑功率<15瓦输入超范围保护150 VDC连续,115 VAC连续输入电流范围0至20 mA,带250Ω分流电阻器现场至系统隔离800 VDC最小模块状态指示灯通过、故障、激活、现场输入诊断故障范围1最小输入变化输入变化采样周期最小误比较周期1。快速或连续改变输入可能会导致检测故障的时间增加。如果输入样本与前一样本的变化超过0.25%,则不会比较读数。2%的满量程20 ms 25样本模拟输入模块53 Tricon v9–v10系统16点隔离模拟输入模块规划和安装指南该图是3703E型的简化示意图,它是一个16点TMR模拟输入模块,可配置为0至5 VDC或0至10 VDC。图20 3703E简化的单个点场示意图智能I/O控制器(S)三重I/O总线信号调节模拟输入电路–每个支路多路复用器A总线Xcvr Amp ADC多路复用器B总线Xcvr-Amp ADC复用器C总线XcvrAmp ADCµProcµProc 54第2章Tricon系统组件规划和安装指南v9–v10系统此图显示了3703E型的前面板。图21 3703E前面板芥末黄色条纹隔离模拟输入3703E 0-5或0-10 VDC PASS FAULT ACTIVE模拟输入模块55 Tricon v9–v10系统3703E规范规划和安装指南本节包括3703E型号的规范,该型号为隔离TMR模拟输入模块。警告:如果超过某个信道的共模电压范围,Triconex不能保证模块的正常运行和其他信道的准确性。表15 3703E模拟输入规格特性规格颜色代码芥末黄色输入信号数量16差分,隔离输入更新率<50 ms分辨率12位精度<FSR的0.15%,从0°C到60°C输入电阻(负载)最小30 MΩ(DC)断电时输入电阻最小30 M欧(DC)共模抑制(典型)-90 dB@60 Hz,最小,-100 dB@DC最小共模范围±200 VDC最大值(信道到信道或信道到地)信道到信道隔离20 kΩ典型值

     WARNING If the common-mode voltage range of a channel is exceeded, Triconex does not guarantee proper operation of the module and accuracy of other channels. Table 13 3701 Analog Input Specifications Feature Specification Color code Light yellow Number of input signals 32 differential, DC-coupled Input update rate 55 ms Resolution 12 bits Accuracy < 0.15% of FSR from 0° – 60° C Input resistance (load) 30 MΩ (DC), minimum Input resistance @ power off 30 kΩ (DC), typical Common mode rejection (typical) -80 dB (DC - 100 Hz) Common mode voltage range (See Warning) -12V to +12V peak Channel-to-channel isolation 200 kΩ, typical Normal mode rejection -3 dB @ 8 Hz -17 dB @ 60 Hz -23 dB @ 120 Hz Input voltage range 0 to 10 V Logic power < 10 watts Input over-range protection 150 VDC continuous, 115 VA continuous Input current range 0 to 20 mA with 500 Ω shunt resistor Module status indicators Pass, Fault, Active Input diagnostic fault coverage1 Minimum input change Input change sample period Minimum period of mis-compares 1. Rapidly or continuously changing inputs may cause mis-compare readings because the measured values of the three channels may different by more than 0.5 percent of full scale, which can cause a fault to be declared in error. If the input readings differ by a minimum of 2 percent of full scale and continue for a minimum period of 40 input samples, the probability of a fault increases. 2% of full scale 1 scan or 200 ms, whichever is greater 40 samples 52 Chapter 2 System Components Planning and Installation Guide for Tricon v9–v10 Systems 3721 Specifications This section includes specifications for model 3721, which is a TMR Analog Input Module with a voltage range of 0 to 5 VDC or -5 to +5 VDC. The 3721 module can be installed only in Tricon v10.2 and later systems. Note The 3721 can be installed in low-density systems that have been upgraded to v10.2.x or later. For more information, see Appendix I, Low-Density Chassis I/O Module Compatibility in the Field Terminations Guide for Tricon v9–v10 Systems. Table 14 3721 Analog Input Specifications Feature Specification Color code Yellow Number of input signals 32 differential, DC-coupled Input update rate 10 ms Resolution 12 bits or 14 bits programmable Accuracy < 0.15% of FSR from 0° to 60° C Input resistance (load) 10 MΩ (DC), minimum Input resistance at power off 140 kΩ (DC), typical Common mode rejection (typical) -85 dB (DC - 100 Hz) Common mode voltage range -12V to +12V peak Channel-to-channel isolation 420 kΩ, typical Normal mode rejection -3 dB @ 23 Hz -8 dB @ 60 Hz -14 dB @ 120 Hz Input voltage range 0 to 5 or –5 to 5 VDC Input over-range measurement +6%, -5.3 to +5.3 VDC Logic power < 15 watts Input over-range protection 150 VDC continuous, 115 VAC continuous Input current range 0 to 20 mA with 250 Ω shunt resistor Field to system isolation 800 VDC minimum Module status indicators Pass, Fault, Active, Field Input diagnostic fault coverage1 Minimum input change Input change sample period Minimum period of mis-compares 1. Rapidly or continuously changing inputs may cause the time to detect a fault to increase. If an input sample changes by more that 0.25% from the previous sample the readings will not be compared. 2% of full scale 20 ms 25 samples Analog Input Modules 53 Planning and Installation Guide for Tricon v9–v10 Systems 16-Point Isolated Analog Input Modules This figure is a simplified schematic for model 3703E, which is a 16-point TMR Analog Input Module that can be configured as 0 to 5 VDC or 0 to 10 VDC. Figure 20 3703E Simplified Schematic Individual Point Field Te mr inations INTELLIGENT I/O CONTROLLER(S) TRIPLICATED I/O BUS SIGNAL CONDITIONING ANALOG INPUT CIRCUIT – TYPICAL POINT INDIVIDUAL ADC FOR EACH LEG Multiplexer A Bus Xcvr Amp ADC Multiplexer Bus B Xcvr Amp ADC Multiplexer C Bus Xcvr Amp ADC µProc µProc µProc 54 Chapter 2 System Components Planning and Installation Guide for Tricon v9–v10 Systems This figure shows the front panel of model 3703E. Figure 21 3703E Front Panel Mustard Yellow Stripe ISOLATED ANALOG INPUT 3703E 0-5 or 0-10 VDC PASS FAULT ACTIVE Analog Input Modules 55 Planning and Installation Guide for Tricon v9–v10 Systems 3703E Specifications This section includes specifications for model 3703E, which is an isolated TMR Analog Input Module. WARNING If the common-mode voltage range of a channel is exceeded, Triconex does not guarantee proper operation of the module and accuracy of other channels. Table 15 3703E Analog Input Specifications Feature Specification Color code Mustard yellow Number of input signals 16 differential, isolated Input update rate < 50 ms Resolution 12 bits Accuracy < 0.15% of FSR, from 0° to 60° C Input resistance (load) 30 MΩ (DC) minimum Input resistance @ power-off 30 MΩ (DC) minimum Common mode rejection (typical) -90 dB @ 60 Hz, minimum, -100 dB @ DC minimum Common mode range ± 200 VDC maximum (channel-to-channel or channel-to-ground) Channel-to-channel isolation 20 kΩ typical Normal mode rejection -3 dB @ 8 Hz -17 dB @ 60 Hz -23 dB @ 120 Hz Input range voltage 0–5 VDC or 0–10 VDC, TriStation-configurable Input over-range measurement +6%, 0–5.3 VDC or 0–10.6 VDC Logic power < 15 watts Input over-range protection 115 VAC continuous, 150 VDC continuous Open detect Upscale or downscale, TriStation-configurable Input range current 0 – 20 mA with 250 Ω shunt resistor Module status indicators Pass, Fault, Active Input diagnostic fault coverage1 Minimum input change Input change sample period Minimum period of mis-compares 0.5% of full scale 1 scan or 50 ms, whichever is greater 256 samples 56 Chapter 2 System Components

    2022.12.14.jpg

    23.jpg

    21.jpg

    20.jpg

    18.jpg



    品牌: GE

    型号:IS200ISBAH1A 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号