IS200EXTBG1AAA模拟器,模拟量输入控制卡
((TM2)额定值均为Class 2 18 SW1功能描述SWITCH 1外部信号类型0~20mA模拟信号(当Fn11设置为1时)4~20mA模拟信号。尺寸和接线板布局框架1:U20N0K2、U20N0K4、U20K0C7长度类型D E F G U20N0K2U20N0K6 U20N0C7 8.2 118 61 72注意:出于安全原因,我们强烈建议用户拆除M4“绿色”接地螺钉,然后将封闭的“金属框架接地端子”拧在同一位置,以形成接地棒,确保良好的接地保护。Plaquette de terre(voir note)terre接地(见注释)接地19框架2:U20N1K5、U20N2K2、U20X0K7、U20X1K5、U20X2K2 Plaquete de terre,然后将封闭的“金属框架接地端子”拧在同一位置,形成接地棒,以确保良好的接地保护。接地(见注释)接地20安装B级滤波器(U20AF0K7)的逆变器的尺寸和安装。安装有B级滤波器(U20AF0K7)和DIN导轨(U20AR0K7)的逆变器。21安装螺钉操作图DIN导轨(U20AR0K7)操作图中间肋固定肋插入孔步骤1对准并将U20AR0K 7的4个固定肋插入VAT20后面板的4个孔。步骤2将U20AR0K7向前推,直到中间肋骨与真实面板牢牢夹住。步骤1使用小螺丝刀插入U20AR0K 7的中间肋骨,然后按压螺丝刀,以便从VAT20上剥离U20AR0K7。22安装板拉动安装板1 2螺丝刀DIN导轨安装安装夹具和35 mm宽的导轨必须用于在导轨上安装VAT20。安装VAT20拆卸VAT20安装夹具(1)DIN导轨(1)必须使用安装夹具固定VAT20 1向下拉动安装板。2旋转T型转换器模块将其卸下。首先将模块背面的凹槽放在导轨上边缘,然后将模块向下推至锁定位置。最后将安装板向上压入模块。23第3章。软件索引3.1。控制面板说明小心不要用螺丝刀或其他锋利的工具操作键盘,以免损坏键盘。简短的键盘操作流程图(1)停止时显示设置频率。运行时显示输出频率。(2) 可以在停止或运行时修改设置频率。(频率)(1)(频率)▲ ▼ 数据ENT运行停止DSP FUN电源LED F××DSP FUN DSP FUN F×××数据ENT(读取)结束××数据nt(写入)0.5秒后(2)24 3.2。参数列表功能FN_功能描述单位范围出厂设置注释0出厂调整0加速/1加速时间0.1秒0.1~999 S 5.0(1)(3)减速时间2减速时间0.1秒0.1~999 S 5.0(3)操作模式3 0:前进/停止,后退/停止1:运行/停止,正向/反向1 0~1 0电机方向4 0:正向1:反向1 0~10(1)V/F模式5 V/F模式设置1 1~6 1/4(2)6频率上限0.1Hz 1.0~120Hz 1.0~200Hz 50/60Hz(2)(3)频率(4)上限/下限7频率下限0.1Hz 0.0~120Hz 0.0~200Hz 0.0Hz(3)(4)SPI频率8 SP1频率0.1Hz 1.0~120Hz 1.0~2000Hz 10Hz(4)JOG频率9 JOG频率0.1Hz 1.0~120Hz 1.0~200Hz 6Hz(4)操作控制10 0:键盘1:外部端子1 0~1 0频率控制11 0:键盘2:外部端子(0~10v/0~20mA)2:外部终端(4~20mA)1 0~2 0载波频率12载波频率设置1 1~5 1~10 5(4)扭矩补偿13扭矩补偿增益0.1%0.0~10.0%0.0%(1)停止方法14 0:减速停止,1:自由运行停止1 0~1 0 15 DC制动时间0.1S 0.0~25.5S 0.5S DC制动设置16 DC制动注入频率0.1Hz 1~10Hz 1.5Hz 17 DC
TM2) Ratings are all Class 2 18 SW1 function description SWITCH 1 External signal type 0~20mA analog signal ( When Fn11 set to 1 ) 4~20mA analog signal ( When Fn11 set to 2 ) 0~10 VDC analog signal ( When Fn11 set to 1 ) 2.5. Dimensions and terminal block layout Frame 1: U20N0K2, U20N0K4, U20N0K7 Length Type D E F G U20N0K2 U20N0K4 U20N0K7 8.2 118 61 72 NOTE For safety reason, we strongly recommend users to remove the M4 ‘green’ grounding screw, then screw the enclosed ‘metal frame grounding terminal’ on the same location to make a grounding bar to ensure good earth protection. Plaquette de terre (voir note) Terre Grounding (see note) Grounding 19 Frame 2: U20N1K5, U20N2K2, U20X0K7, U20X1K5, U20X2K2 Plaquette de terre (voir note) M4 terre NOTE For safety reason, we strongly recommend users to remove the M4 ‘green’ grounding screw, then screw the enclosed ‘metal frame grounding terminal’ on the same location to make a grounding bar to ensure good earth protection. Grounding (see note) Grounding 20 Dimensions and Installation of class B filter (U20AF0K7) Inverter with class B filter (U20AF0K7) mounted. Inverter with class B filter (U20AF0K7) and DIN rail (U20AR0K7) mounted. 21 Mounting screw operation diagram DIN rail (U20AR0K7) operation diagram middle rib Retention rib Inserting hole Step 1 Aim and insert the 4 retention ribs of U20AR0K7 at the 4 holes in rear panel of VAT20 . Step 2 Push the U20AR0K7 forward until the middle rib grips firmly with real panel Step 1 Use small screw driver inserting the middle rib of U20AR0K7 and press the screw driver in order to strip U20AR0K7 from VAT20. 22 Mounting plate Pull mounting plate 1 2 Screwdriver DIN rail installation Mounting clamp and 35 mm width rail must be used to install VAT20 on the rail. Install VAT20 Dismounting VAT20 Mount Mounting clamp(1) DIN Rail (1) Mounting clamp must be used to fasten VAT20 1 Pull the mounting plate downward. 2 Rotate the T-verter module to dismount it. First place the groove on the back of module on the upper edge of din rail , and then push the module down to lock up position. Finally press the mounting plate upward into module. 23 Chapter 3. Software Index 3.1. Control Panel Instructions CAUTION Do not operate keypad by screwdriver or other sharp-ended tool to avoid damaging keypad. Brief keypad operation flowchart (1) Displayed setting frequency when stopped. Display output frequency when running. (2) The setting frequency can be modified either when stopped or when running. (FREQ) (1) (FREQ) ▲ ▼ DATA ENT RUN STOP DSP FUN POWER LED F ×× DSP FUN DSP FUN F ×× ××× DATA ENT (READ) END ××× DATA ENT (WRITE) AFTER 0.5 SEC (2) 24 3.2. List of parameters Function FN_ Function Description Unit Range Factory setting Note 0 Factory Adjustment 0 Accelerate / 1 Accelerate time 0.1 sec 0.1 ~ 999 S 5.0 (1)(3) Decelerate Time 2 Decelerate time 0.1 sec 0.1 ~ 999 S 5.0 (1)(3) Operation mode 3 0: Forward / Stop, Reverse / Stop 1:Run/Stop, Forward / Reverse 1 0 ~ 1 0 Motor direction 4 0: Forward 1: Reverse 1 0 ~ 1 0 (1) V/F Pattern 5 V/F pattern setting 1 1 ~ 6 1/4 (2) 6 Frequency upper limit 0.1Hz 1.0 ~ 120Hz 1.0 ~ 200Hz 50/60Hz (2)(3) Frequency (4) upper/lower limit 7 Frequency lower limit 0.1Hz 0.0 ~ 120Hz 0.0 ~ 200Hz 0.0Hz (3) (4) SPI frequency 8 SP1 frequency 0.1Hz 1.0 ~ 120Hz 1.0 ~ 200Hz 10Hz (3) (4) JOG frequency 9 JOG frequency 0.1Hz 1.0 ~ 120Hz 1.0 ~ 200Hz 6Hz (4) Operation control 10 0:keypad 1: external terminal 1 0 ~ 1 0 Frequency control 11 0:keypad 1:external terminal(0~10v/0~20mA ) 2: external terminal ( 4~20mA ) 1 0 ~ 2 0 Carrier frequency 12 Carrier Frequency setting 1 1 ~ 5 1 ~ 10 5 (4) Torque compensation 13 Torque compensation gain 0.1% 0.0 ~ 10.0% 0.0% (1) Stop method 14 0:decelerate stop, 1:free run stop 1 0 ~ 1 0 15 DC braking time 0.1S 0.0 ~ 25.5S 0.5S DC braking setting 16 DC braking injection frequency 0.1Hz 1 ~ 10Hz 1.5Hz 17 DC