IS200TDBSH2 IS200TDBSH2AAA自动化卡件,模块卡件

IS200TDBSH2 IS200TDBSH2AAA自动化卡件,模块卡件

IS200TDBSH2 IS200TDBSH2AAA自动化卡件,模块卡件 对于没有强制空气的CPU型号CPM790。有关风扇组件的目录号,请参阅机架。存储温度–40C至85C(–40至185F)湿度5至95%非冷凝振动5–9 Hz 3.5mm位移:9–150 Hz,1.0 G冲击15 G,持续11毫秒Genius组件工作温度0至60C(32至140F)存储温度–0至+100C(-40至+212F)...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

IS200TDBSH2 IS200TDBSH2AAA自动化卡件,模块卡件

    IS200TDBSH2 IS200TDBSH2AAA自动化卡件,模块卡件

     对于没有强制空气的CPU型号CPM790。有关风扇组件的目录号,请参阅机架。存储温度–40°C至85°C(–40至185°F)湿度5至95%非冷凝振动5–9 Hz 3.5mm位移:9–150 Hz,1.0 G冲击15 G,持续11毫秒Genius组件工作温度0至60°C(32至140°F)存储温度–0至+100°C(-40至+212°F)温度5至95%无冷凝振动5-10 Hz 5.08mm位移,10–200 Hz,1.0 G现场控制组件工作温度0至55°C(32至131°F)存储温度–40至+85°C(-40至+185°F)湿度5至95%非冷凝振动10至57 Hz,位移0.012(p–p)57至500 Hz,2 G(或按规定)冲击15G,11 ms,半正弦波机构批准,符合性,标准_德国莱茵TÜV TÜV–Genius模块化冗余系统已通过德国莱茵TÉV集团的以下系统配置和等级认证:n三重模块冗余(TMR 2v3)容错和故障安全,最高等级为6级。n双工(2v2)故障保护,最高等级为5级。n双工(1v2)容错和故障安全,最高等级为4级。有关详细信息和限制,请参阅TÜV报告945/EL 340/96或联系GE Fanuc了解更多信息。ISO GE Fanuc Automation已通过ISO 9000认证和ISO 9001注册。GE Fanuc也在美国保险商实验室、英国标准协会和加拿大标准协会质量管理协会注册。标准大多数GMR组件(90-70,现场控制和Genius)符合以下标准。然而,并非每个组件都符合列出的所有标准。有关具体信息,请参阅相应的技术手册或联系您的GE Fanuc销售办公室。IEC第142号、C22.2 435380 CSA C22.2 JIS A–1978 C 0912、JIS C 0911 ANSI/IEEE C–37.90 DIN 871–877 435、380 VDE 805、806、UL A 508、1012 FCC 15J部分危险场所I类,II类。NEMA/ICS 2–230.40 VME C.1本文件部件列表中先前标识为TÜV认证(是)的部件也已根据标识标准通过以下测试,这些测试是TÜV认证所必需的。冷试验IEC 68–2–1干热试验IEC 68-2–2冲击试验IEC 68—2–27温度变化试验IEC 68?2–14湿热循环试验IEC 68-2–30振动试验IEC 68——2–6静电放电IEC 801–2 RF&Electromag。抗扰度IEC 801–3突发测试IEC 801–4浪涌测试ANSI/IEEE 37.90.1过电压测试DIN VDE 0160–7.3 P.S.中断测试DIN VDE0116 P.S.变化测试DIN VDE011 6 4-8 Genius®模块化冗余灵活三模块冗余(TMR)系统GFT-177A技术产品概述–1998年2月4机架标准机架可提供五槽面板安装、九槽面板安装,和19英寸机架安装样式。还提供了一个带有17个标准VME插槽的机架,可用于促进第三方模块的集成。它也有面板安装式或机架安装式。每个机架都可以用作主CPU机架或扩展机架。机架式风扇组件可用于存在热量积聚问题的安装。风扇噪音低,使用滚珠轴承延长使用寿命。模块固定所有90-70系列模块都有模制闩锁,当模块完全插入时,该闩锁会自动卡在机架的上下导轨上。可选地,M2.5X8螺钉可用于将模块固定到机架上,以用于高振动应用。插槽盖未使用的机架插槽应覆盖空白插槽盖,以尽量减少连接器暴露于异物中。机架和安装规格尺寸高度宽度深度九槽机架266mm 10.47“483mm 19.00”190mm 7.5“五槽

    for CPU model CPM790 without forced air. See racks for catalog number of fan assembly. Storage Temperature –40° to 85° C (–40 to 185°F) Humidity 5 to 95% non-condensing Vibration 5–9 Hz 3.5mm displacement: 9–150 Hz at 1.0 G Shock 15 Gs for 11 msec Genius Components Operating Temperature 0 to 60° C (32 to 140°F) Storage Temperature –40 to +100° C (–40 to +212° F) Humidity 5 to 95% non-condensing Vibration 5–10 Hz 5.08mm displacement, 10–200 Hz at 1.0 G Field Control Components Operating Temperature 0 to 55° C (32 to 131°F) Storage Temperature –40 to +85° C (–40 to +185° F) Humidity 5 to 95% non-condensing Vibration 10 to 57 Hz 0.012 in displacement (p–p) 57 to 500 Hz at 2 g (or as specified) Shock 15G, 11 ms, half sine wave Agency Approvals, Compliances, Standards _ TÜV TÜV Rheinland – The Genius Modular Redundancy system has been certified by TÜV Rheinland for the following system configurations and classes: n Triple Modular Redundant (TMR 2v3) Fault Tolerant and Fail Safe up to Class 6. n Duplex (2v2) Fail Safe up to Class 5. n Duplex (1v2) Fault Tolerant and Fail Safe up to Class 4. For details and restrictions, refer to TÜV report 945/EL 340/96 or contact GE Fanuc for more information. ISO GE Fanuc Automation is ISO 9000 certified and ISO 9001 registered. GE Fanuc is also registered with Underwriters Laboratories (USA), the British Standards Institute (UK) and the Quality Management Institute of the Canadian Standards Association. Standards Most GMR components (90-70, Field Control and Genius ) comply with the following standards. However not every component complies with every standard listed. For specific information, please refer to the appropriate technical manual or contact your GE Fanuc Sales office. IEC No. 142, C22.2 435,380 CSA C22.2 JIS A–1978 C 0912, JIS C 0911 ANSI/IEEE C–37.90 DIN 871–877 435, 380 VDE 805, 806, UL A 508, 1012 FCC 15J Part Hazardous Location Class I, Div II . NEMA/ICS 2–230.40 VME C.1 Those components identified earlier in the components list of this document which were marked as being TÜV approved (YES) also have passed the following tests per the identified standards, which are required for TÜV approval. Cold test IEC 68–2–1 Dry Heat test IEC 68–2–2 Shock test IEC 68–2–27 Change of Temp test IEC 68–2–14 Damp Heat Cyclic test IEC 68–2–30 Vibration test IEC 68–2–6 Electrostatic Discharge IEC 801–2 RF & Electromag. Immunity IEC 801–3 Burst test IEC 801–4 Surge test ANSI/IEEE 37.90.1 Overvoltage test DIN VDE 0160 – 7.3 P.S. Interrupt test DIN VDE 0116 P.S. Variation test DIN VDE 0116 4-8 Genius® Modular Redundancy Flexible Triple Modular Redundant (TMR) System GFT-177A Technical Product Overview – February 1998 4 Racks Standard racks are available in five-slot panel-mount, nine-slot panel mount, and 19-inch rack-mount styles. Also available is a rack with 17 standard VME slots which can be used to facilitate integration of 3rd-party modules. It is also available in panel-mount or rackmount styles. Each of the racks can function either as the main CPU rack or as an expansion rack. Rack fan assemblies are available for use in installations where heat buildup is a problem. The fans have a low noise level and use ball bearings for extended life. Module Retention All Series 90-70 modules have molded latches that automatically snap onto the upper and lower rails of the rack when the module is fully inserted. Optionally M2.5X8 screws may be used to secure the modules to the rack for high vibration applications. Slot Covers Unused rack slots should be covered with blank slot covers to minimize connector exposure to foreign material. Rack and Mounting Specifications Dimensions Height Width Depth Nine Slot Rack 266mm 10.47” 483mm 19.00” 190mm 7.5” Five Slot 

    手机轮播图2(1)_副本.jpg

    23.jpg

    20.jpg

    14.jpg



    品牌: GE

    型号:IS200TDBSH2 IS200TDBSH2AAA 

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号