您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

IS200TREGH2B处理器卡件,机器人卡件

IS200TREGH2B处理器卡件,机器人卡件

IS200TREGH2B处理器卡件,机器人卡件在–10至+10V范围内,在–10到+10V的输入电压范围内,从发送或接收–32768至32767之间的值。两个电流范围为、和。在每个当前范围中,从模块返回0到32767之间的值,以发送到整个范围的模块。IC693ALG442 Alog Combination I/O模块12 GFK–0898F第12章–IC693ALGA442 Alog-Combit...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

IS200TREGH2B处理器卡件,机器人卡件

    IS200TREGH2B处理器卡件,机器人卡件

    在–10至+10V范围内,在–10到+10V的输入电压范围内,从发送或接收–32768至32767之间的值。两个电流范围为、和。在每个当前范围中,从模块返回0到32767之间的值,以发送到整个范围的模块。IC693ALG442 Alog Combination I/O模块12 GFK–0898F第12章–IC693ALGA442 Alog-Combition I/O模块12-17从发送到模块的值下表显示了从发送到s模块的值。量程模块模式*允许值发送值从V电压0到32767 0到32767-10到10 V电压-32768到32767–32768到32767电流0到32000*0到32767.电流0到327670-32767*允许值指的是盖子的值。如果发送了超出指定范围的路厄值,则模块会将其夹在最近的盖子路厄值上,然后再将其发送到数字至路厄转换器。返回错误。下表显示了从模块发送回输入s的PLC的值。范围模块模式发送的值为V电压0至32767–10至10 V电压–32768至32767电流0至3277电流0至32567增强电流–8000至32767报警低和报警高数据字段允许您输入导致报警指示传递至PLC的值值。每个都有一个下限报警值(报警低)和一个上限报警值(警报高)。这些报警值导致%I点设置,如第3-95页和第3-96页的表格所示。可以在所有上限和下限字段中输入值。假设输入的值没有符号为正。允许的路值如下表所示。范围可能限值032760 032760增强型–800032760V 032760–10至+10V–3276832760 12 12-18系列90–30 PLC I/O模块规格–2000 GFK–0898F IC693ALG442斜坡模式操作斜坡模式操作代表模块的单独模式。当处于斜坡模式时,在相应的%AQ参考中输入的新值会导致步进到合并值,如图3-52所示。当处于斜坡模式时,在相应的%AQ参考中输入的新值会导致使用已分配给使用梯形图逻辑的斜坡变量斜坡到给定值。斜坡由每1毫秒采取的步骤组成。%对应于新%AQ LUE图12-7的标准模式时间胶片LUE中的斜坡模式示例中的AQ LUE变化示例。渐变模式和标准模式中的行为这两种模式的默认模式都是标准模式。斜坡模式和斜坡变量使用E2在梯形逻辑中设置,如下所述。每个模式的设置独立于另一个模式。当处于斜坡模式时,可以使用两种较低级别的模式来指定斜坡斜率:时间模式,用户以毫秒为单位提供总斜坡时间;步进模式,用户提供每1毫秒进行一次的%AQ计数。设置斜坡模式E2用于更改的斜坡模式。这与用于更改模块的输入报警限值和清除%I错误代码的方法相同。当模块接收到时,将检查第一个字或第二个字,以确定是否正在更改斜坡设置或报警限制,或是否正在清除%I错误代码。当指定步进模式时,第二个数据字包含以%AQ计数表示的斜坡步进。盖阶跃值范围为1至32000。当相应%AQ参考值的值改变时,确定斜坡的方向。一旦设置了渐变模式和步骤,更改相应的%AQ值将导致渐变到新的值。当指定时间模式时,第二个数据字包含从当前值渐变到最终值所需的总时间(以毫秒为单位)。当前值和当前值由相应%AQ参考的旧值和新值指定。盖子斜坡时间的范围从1到32000,对应于1毫秒到32秒的斜坡时间。一旦设置了渐变模式和时间,更改相应的%AQ值将导致渐变到新的值。如果向模块发出E2以更改斜坡设置,而指示的模块正在斜坡过程中,则新的斜坡设置将

    In the –10 to +10V range, lues between –32768 to 32767 are sent or received from the over an input voltage range of –10 to +10V. The two current ranges are , and . In each of the current ranges, lues between 0 and 32767 are reported back from the module to sent to the module for the entire range. IC693ALG442 Alog Combition I/O Module 12 GFK–0898F Chapter12 – IC693ALG442 Alog Combition I/O Module 12-17 lues Sent From to Module for s The following tables show lues sent from the to the module for the s. Range Module Mode *Allowed lues Sent lues from V Voltage 0 to 32767 0 to 32767 –10 to 10 V Voltage – 32768 to 32767 –32768 to 32767 Current 0 to 32000* 0 to 32767 Current 0 to 32767 0 to 32767 * Allowed lues refers to the lues that are lid. If a lue outside the specified range is sent, the module clips it to the nearest lid lue before sending it to the Digital to Alog Converter. errors are returned. The following table shows lues sent from the module back to the PLC for the Input s. Range Module Mode Sent lues to V Voltage 0 to 32767 –10 to 10 V Voltage –32768 to 32767 Current 0 to 32767 Current 0 to 32767 Enhanced Current –8000 to 32767 The ALARM LO and ALARM HI data fields allow you to enter lues that cause alarm indications to be passed to the PLC. Each has a low limit alarm lue (ALARM LO) and a high limit alarm lue (ALARM HI). These alarm lues cause %I points to be set as indicated in the tables on page 3-95 and 3-96. lues can be entered in all high and low limit fields. lues entered without a sign are assumed to be positive. The allowable lues are shown in the following table. RANGE Possible limit lues 032760 032760 Enhanced –800032760V 032760 –10 to +10V –3276832760 12 12-18 Series 90–30 PLC I/O Module Specifications – 2000 GFK–0898F IC693ALG442 Ramp Mode Operation The ramp mode operation represents a separate mode of the module’s s. When an is t in ramp mode, new lues entered in the corresponding %AQ reference cause the to step to the comnded lues as shown in Figure 3-52. When an is in ramp mode, new lues entered in the corresponding %AQ reference cause the to ramp to the given lues using ramp riables which have been assigned to the using ladder logic. The ramp is composed of steps taken every 1 millisecond. %AQ LUE CHANGES EXAMPLE IN RAMP MODE EXAMPLE IN STANDARD MODE TIME FIL LUE CORRESPONDING TO NEW %AQ LUE Figure 12-7. Behavior in Ramp Mode and in Standard Mode The default mode of both s is standard mode. Ramp mode and ramp riables are set using an E2 in ladder logic as described below. The mode of each is set independent of the mode of the other . When an is in ramp mode, two lower-level modes can be used to specify the ramp slope: time mode, in which the user provides the total ramp time in milliseconds, and step mode, in which the user provides the step in %AQ counts that will be taken every 1 millisecond. Setting the Ramp Mode An E2 is used to change the ramp mode of an . This is the same that is used to change the input alarm limits of the module and clear the %I error code. When the module receives the , the first word, or comnd word, is checked to determine whether the ramp settings or alarm limits are being changed or whether the %I error code is being cleared. When step mode is specified, the second data word contains the ramp step in %AQ counts. lid step lues range from 1 to 32000. The direction of the ramp is determined when the lue of the corresponding %AQ reference changes. Once the ramp mode and step have been set, changing the corresponding %AQ lue causes the to ramp to the new lue. When time mode is specified, the second data word contains the total time in milliseconds it will take for the to ramp from the present lue to the fil lue. The present and fil lues are specified by the old and new lues of the corresponding %AQ reference. lid ramp time lues range from 1 to 32000, which correspond to ramp times of 1 millisecond to 32 seconds. Once the ramp mode and time have been set, changing the corresponding %AQ lue causes the to ramp to the new lue. If an E2 is issued to the module to change the ramp settings while the indicated is in the process of ramping, the new ramp settings will

    fa405aeea632aa6912154382925a28b_副本.jpg

    ABB 5SHX2645L0002.jpg

    ABB 3HAC025338-006.jpg

    9.jpg


    品牌: GE

    型号:IS200TREGH2B

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货



图片名 客服

在线客服 客服一号