2/24伏直流负逻辑0.5安培模块。总模块负载电流环境温度a45049()图7-25。IC693MDL741 7 7-28 Series 90-30 PLC I/O模块规格的负载电流与温度–2000 GFK-0898F 12/24 V DC正极逻辑ESCP-1安培,16点IC693MDL 742 Series 90-30的12/24 V直流正极逻辑1安培电子短路保护(ESCP)模块提供两组16点,每组8个,每组一个电源端子。该模块设计为具有正逻辑特性,因为它从用户或正电源总线向负载提供电流。该设备连接在负电源总线和模块之间。该特性与广泛的用户提供的负载设备兼容,例如:电机起动器、定子和指示器。操作现场设备的电源必须由用户提供。提供各点开/关状态的LED指示灯位于模块顶部。该LED块有两个水平行,每行有八个绿色LED,顶行标记为A1-A8(点1至8),底行标记为B1-B8(点9至16)。右侧的红色LED(标记为“F”)位于两排绿色LED中间,用作跳闸的电子短路保护指示器;当发生任何短路保护跳闸时,其开启。每个组的sigl都是电子监控的。如果发生短路,组中的点将关闭,红色LED将打开。指示点状态的LED将不会关闭。此保护不会保护单个点不超过其额定值,但会在负载短路时保护电路板。要重置电子短路保护,请移除模块的12/24用户电源。该模块具有两个电子短路保护;每个保护八个s-第一个保护A1-A8,第二个保护B1-B8。铰链门的内外表面之间有一个插件。朝向模块内部的表面(当铰链门关闭时)具有接线信息,并且识别信息可以记录在外表面上。插件的左外边缘为蓝色,表示低压模块。此模块上有保险丝。该模块可安装在Series 90-30 PLC系统中5或10插槽基板的任何I/O插槽中。表7-14。IC693MDL742额定电压12/24伏DC电压范围12至24伏DC(+20%,-15%)s每个模块16(两组,每组8个)场侧和逻辑侧之间的隔离1500伏组间500伏电流每点4安培@50C时每组3个@60C特性浪涌电流5.2 10 ms压降1.2伏关断状态漏电1接通响应时间2毫秒关闭响应时间2毫秒背板负载电流上5伏总线的功耗130(全部打开)取决于环境温度,如下页图表所示。产品标准和一般规范参见附录B。离散模块7 GFK-0898F第7章-离散模块7-29 IC693MDL742模块现场接线信息下图提供了将用户提供的负载设备和电源连接到12/24伏直流正逻辑ESCP-1安培模块的接线信息。端子现场接线模块负载电流环境温度每组3个,每组4个()a45242图7-27。IC693MDL742 7 7-30 Series 90-30 PLC I/O模块规格的负载电流与温度–2000 GFK-0898F隔离继电器,N.O.,4 Amp-8点IC693MDL 930 Series 90-30可编程逻辑控制器的4 Amp隔离继电器模块提供8个全开继电器,用于控制用户提供的负载。每个开关的开关容量为4。每个点都与其他点隔离,每个点都有一个单独的电源端子。
2/24 volt DC negative logic 0.5 amp module. TOTAL MODULE LOAD CURRENT AMBIENT TEMPERATURE a45049 () Figure 7-25. Load Current vs. Temperature for IC693MDL741 7 7-28 Series 90-30 PLC I/O Module Specifications – 2000 GFK-0898F 12/24 Volt DC Positive Logic ESCP - 1 Amp, 16 Point IC693MDL742 The 12/24 volt DC Positive Logic 1 Amp Electronic Short Protection (ESCP) module for the Series 90-30 PLC provides 16 points in two groups of eight with a power termil for each group. This module is designed to have positive logic characteristics in that it sources current to the loads from the user or positive power bus. The device is connected between the negative power bus and the module . The characteristics are compatible with a wide range of user-supplied load devices, such as: motor starters, soleids, and indicators. Power to operate the field devices must be supplied by the user. LED indicators that provide the ON/OFF status of each point are located at the top of the module. This LED block has two horizontal rows with eight green LEDs in each row with the top row labeled A1 - A8 (points 1 through 8) and the bottom row labeled B1 - B8 (points 9 through 16). A red LED (labeled “F”) on the right, centered between the two rows of green LEDs, functions as a tripped electronic short protection indicator; it turns ON when any short protection trip occurs. The sigl for each group is monitored electronically. If a short occurs, the points in the group turn off and the red LED turns on. The LEDs indicating point status will t turn off. This protection does t protect individual s from exceeding their ratings, but will protect the board in case of a short ed load. To reset electronic short protection remove the 12/24 user supply to the module. The module has two electronic short protection s; each protects eight s - the first protects A1 - A8, the second protects B1 - B8. An insert goes between the inside and outside surface of the hinged door. The surface towards the inside of the module (when the hinged door is closed) has wiring infortion, and identification infortion can be recorded on the outside surface. The outside left edge of the insert is color-coded blue to indicate a low-voltage module. There are fuses on this module. This module can be installed in any I/O slot of a 5 or 10-slot baseplate in a Series 90-30 PLC system. Table 7-14. Specifications for IC693MDL742 Rated Voltage 12/24 volts DC Voltage Range 12 to 24 volts DC (+20%, –15%) s per Module 16 (two groups of eight s each) Isolation 1500 volts between field side and logic side 500 volts between groups Current 1 amp per point 4 per group at @ 50C 3 per group @ 60C Characteristics Inrush Current 5.2 for 10 ms Voltage Drop 1.2 volts Off-state Leakage 1 On Response Time 2 ms Off Response Time 2 ms Power Consumption 130 (all s on) from 5 volt bus on backplane load current is dependent upon ambient temperature as shown in graph on following page. Refer to Appendix B for product standards and general specifications. Discrete Modules 7 GFK-0898F Chapter 7 – Discrete Modules 7-29 IC693MDL742 Module Field Wiring Infortion The following figure provides wiring infortion for connecting user supplied load devices and power source to the 12/24 volt DC positive logic ESCP - 1 amp module. TERMILS FIELD WIRING MODULE LOAD CURRENT AMBIENT TEMPERATURE 3 PER GROUP 4 PER GROUP () a45242 Figure 7-27. Load Current vs. Temperature for IC693MDL742 7 7-30 Series 90-30 PLC I/O Module Specifications – 2000 GFK-0898F Isolated Relay , N.O., 4 Amp - 8 Point IC693MDL930 The 4 Amp Isolated Relay module for the Series 90-30 Programble Logic Controller provides 8 rlly-open relay s for controlling loads provided by the user. The switching capacity of each is 4 . Each point is isolated from the other points, and each point has a separate power termil.