IS220PHRAH1B机器人卡件
出版物800T-PP010A-EN-P–2015年4月版权所有©2015,Inc.保留所有权利。美国印刷,LISTEN。思考。解决。和罗克韦尔软件是股份有限公司的商标。商标不属于其各自公司的财产。产品选择触点配置额定值目录编号1-NO、1-NC A600 10A、600V 800TC-XAF触点配置代码1-NO、1-NC AF 2-NO、2-NC、非照明BF 2-NO、2-NC、照明G1F 3-NO、3-NC、非照亮HF 4-NO、4-NC、,无照明CF工厂配置设备产品描述目录号类型4/13目录号类型4/4X/13瞬时触点无照明按钮,黑色,1-NO,1-NC 800T-A2AF 800H-AR2AF瞬时触点照明按钮,绿色,无防护装置的延长头,通用LED,1-NO、1-NC 800T-QBH2GAF 800H-QRBH2GAF非发光触发动作E-stop,标准45 mm红色蘑菇头,2-NO,2-NC 800T-TFXT6BF 800H-TFRXT6BF照明触发动作紧急停止,标准大型红色蘑菇头、通用LED,2-NO、2-NC 800T-TFXJTQH2RG1F————三位无照明选择开关,标准旋钮,维护,标准凸轮,4-NO,4-NC 800T-J2CF 800H-JR2CF二位照明选择开关、标准蓝色旋钮,维护,1-NO,1-NC 800T-2HBH2KB6OX 800H-2HRBH2KB6OX按压测试指示灯,琥珀色,通用LED,1-NO,1-NC 800T-QTH2AAF 800H-QRTH2AAF示例目录号配置安装说明警告:为防止触电,在安装或维修前断开电源。重要事项:800T设备应安装在接地金属外壳中,并正确粘接。将设备安装在金属外壳中时,在接触块和外壳的外露金属部件之间保持1/2“(12.7)的最小间隙。800T设备的额定值为4型和13型,800H设备的额定为4、4X和13型。安装在外壳的平坦光滑表面上。只有在正确安装在具有相同额定值的外壳中时,设备才能保持其类型额定值。紧急停止按钮仅安装在非通风外壳中时,经UL NISD认证。公告800T/800H导向装置(Cat 800T;800H)警告:对于额定为1级2类危险场所的照明和导向装置,爆炸危险-除非电源已关闭或该区域已知无危险,否则不要更换灯泡。对于额定为1类2类危险场所的照明和指示灯装置,必须将透镜装配到装置上。额定为1类2类的设备在设备上有明确的标记。透镜或盖子必须紧贴衬套,以提供紧密密封。安装(见图1和图2)1。从装置上拆下以下零件:透镜或盖、安装环、止推垫圈和图例板或装饰垫圈。2.根据图1中的表格确定要使用的垫片的正确数量。3.将装置从面板后部放入安装孔。4.定位图例板或装饰垫圈,然后定位止推垫圈,止推垫圈柄脚与图例板或饰垫圈和面板槽口接合。5.安装安装环并拧紧止推垫圈至25-30 lb in(2.8-3.4 Nm)。6.将透镜或盖子安装到操作员身上。灯的更换:(卡口底座)1。拆下透镜2。拆下灯:向内推灯,逆时针转动,然后拆下3。安装新灯:插入插座,向内推动并顺时针转动(见图3)4。重新安装镜头可用安装附件:八角形安装环用扳手-目录号800T-N245用于800H指示灯安装环的扳手-目录编号800H-N10用于800T设备的设备连接套件,以满足CSA标准C22.2第0.4号-目录号800 T-N300(F)的连接要求注:括号中的尺寸以毫米为单位。9/16“(14.3)1/4”(6.4)直径。钻机(备用)首选安装说明
Publication 800T-PP010A-EN-P – April 2015 Copyright © 2015 , Inc. All Rights Reserved. Printed in USA. , LISTEN. THINK. SOLVE. and Rockwell Software are trademarks of , Inc. Trademarks not belonging to are property of their respective companies. Product Selection Contact Confi guration Rating Catalog Number 1-NO, 1-NC A600 10A, 600V 800TC-XAF Contact Confi guration Code 1-NO, 1-NC AF 2-NO, 2-NC, non-illuminated BF 2-NO, 2-NC, illuminated G1F 3-NO, 3-NC, non-illuminated HF 4-NO, 4-NC, non-illuminated CF Factory Confi gured Devices Product Description Catalog Number Type 4/13 Catalog Number Type 4/4X/13 Momentary contact non-illuminated push button, black, 1-NO, 1-NC 800T-A2AF 800H-AR2AF Momentary contact illuminated push button, green, extended head without guard, Universal LED, 1-NO, 1-NC 800T-QBH2GAF 800H-QRBH2GAF Non-iIluminated trigger action E-stop, standard 45 mm red mushroom head, 2-NO, 2-NC 800T-TFXT6BF 800H-TFRXT6BF Illuminated trigger action E-stop, standard jumbo red mushroom head, Universal LED, 2-NO, 2-NC 800T-TFXJTQH2RG1F - - - 3-position non-illuminated selector switch, standard knob, maintained, standard cam, 4-NO, 4-NC 800T-J2CF 800H-JR2CF 2-position illuminated selector switch, standard blue knob, maintained, Universal LED, 1-NO, 1-NC 800T-2HBH2KB6OX 800H-2HRBH2KB6OX Push-to-test pilot light, amber, Universal LED, 1-NO, 1-NC 800T-QTH2AAF 800H-QRTH2AAF Example Catalog Number Confi gurations Installation Instructions WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. IMPORTANT: 800T devices should be mounted in and properly bonded to, a grounded metal enclosure. When installing the device in a metal enclosure, maintain 1/2” (12.7) minimum clearance between exposed metal parts of contact block and enclosure. 800T devices are rated Type 4 and 13, 800H devices are rated Type 4, 4X and 13. Install on a flat, smooth surface of an enclosure. Devices maintain their Type ratings only when properly mounted in an enclosure with the same rating(s). Emergency Stop Push Buttons are UL NISD Listed when mounted in a non-ventilated enclosure only. Bulletin 800T / 800H Pilot Devices (Cat 800T; 800H) WARNING: For those illuminated and pilot devices rated for Class 1 Division 2 Hazardous Locations, EXPLOSION HAZARD - Do not replace bulb unless power has been switched off or the area is known to be non-hazardous. For those illuminated and pilot light devices rated for Class 1 Division 2 Hazardous Locations, the lens must be assembled to the device. Those devices rated Class 1 Division 2 are marked specifically as such on the device. Lens or cap must be tight against bushing to provide a tight seal. Installation (see Figs. 1 and 2) 1. Remove the following parts from the unit: Lens or cap, mounting ring, thrust washer and legend plate or trim washer. 2. Determine the correct number of gaskets to be used per the table in Fig. 1. 3. Place the unit into the mounting hole from the rear of the panel. 4. Position legend plate or trim washer and then thrust washer, with thrust washer tang engaging legend plate or trim washer and panel notches. 5. Install mounting ring and tighten against thrust washer to 25 - 30 lb-in (2.8 - 3.4 Nm). 6. Install lens or cap to operator. Lamp Replacement: (Bayonet Base) 1. Remove Lens 2. To remove lamp: Push lamp inward, turn counterclockwise, and remove 3. To install new lamp: Insert in socket, push inward and turn clockwise (see Figure 3) 4. Reinstall Lens Available Mounting Accessories: Wrench for Octagonal Mounting Ring - Catalog No. 800T-N245 Wrench for 800H Pilot Light Mounting Ring - Catalog No. 800H-N10 Device Bonding Kit for 800T devices to meet the bonding requirements of CSA Standard C22.2 No. 0.4 - Catalog No. 800T-N300 (F) NOTE: Dimensions in parentheses are in millimeters. 9/16" (14.3) 1/4" (6.4) Dia. Drill (Alternate) Preferred Mounting Instructions