MVME167-031B处理器卡件

MVME167-031B处理器卡件

MVME167-031B处理器卡件CE欧盟2004108EC EMC指令,符合:EN 61326-1;测量控制实验室。,工业要求EN 61000-6-2;工业抗扰度EN 61000-6-4;工业排放EN 61131-2;可编程控制器(第8条,A区和B区)C-Tick澳大利亚无线电通信Ac符合:AS/NZS CISPR 11;工业排放Ex EU 949EC ATEX指令,符合:EN 60079-15...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

MVME167-031B处理器卡件

    MVME167-031B处理器卡件

    CE欧盟2004108EC EMC指令,符合:EN 61326-1;测量控制实验室。,工业要求EN 61000-6-2;工业抗扰度EN 61000-6-4;工业排放EN 61131-2;可编程控制器(第8条,A区和B区)C-Tick澳大利亚无线电通信Ac符合:AS/NZS CISPR 11;工业排放Ex EU 949EC ATEX指令,符合:EN 60079-15;潜在爆炸性环境保护“n”EN 60079-0;一般要求II 3 G Ex nA IIC T4 X KC韩国广播和通信设备注册符合:无线电波Ac第3条罗克韦尔自动化出版物1756-TD001G-EN-P第58-2条-2013年1月35 1756 ControlLogix控制器GuardLogix极端温度安全合作伙伴储能模块1756-L7SPXT极端温度安全伙伴随附安装了1756-SPESMNSEXT储能模块。表41-技术规范-1756-L7SPXT极端温度安全合作伙伴储能模块属性1756-SPESMNSEXT 1756-SPESM NRMXT描述极端温度安全伙伴的电容器储能模块(可拆卸、剩余WallClockTime备用电源)。如果应用程序要求安装的ESM在将其运入或运出应用程序之前将其剩余能量消耗至40µJ或更低,请使用此ESM。此外,您只能将此ESM与1756-L73(8MB)或更小的内存大小控制器一起使用。在移除ESM之前,至少等待20分钟,使剩余存储能量降至40µJ或更低。电容器储能模块用于安全极端温度伙伴(不可移动,通过防止USB连接和SD卡使用来保护控制器)。如果在插入1756-ESMNRM模块之前安装了SD卡,则SD卡仍能正常工作,但无法移除。此ESM为您的应用程序提供了增强的安全性。电流消耗@5.1V DC 300 mA 330 mA rth美国温度代码T4A IEC温度代码T4外壳类型额定值ne(开放式)表42-环境规范-1756-L7SPXT极端温度安全合作伙伴储能模块属性1756-SPESMNSEXT 1756-SPESM NRMXT温度,运行IEC 60068-2-1(测试A运行低温),IEC 60068-2-2(测试B运行干热),IEC 60068-2-14(试验N工作热冲击)-25…70°C(-13…158°F)温度,工作IEC 60068-2-1(试验A未包装工作冷态),IEC 60068-2-2(试验B未包装工作干热),IEC 6008-2-14(测试N未包装工作热震)-40…85°C(-40…185°F)环境空气温度,最高70°C(158°F)相对湿度IEC 60068-2-30(试验D未包装湿热)5…95%压缩振动IEC 60068-2-6(试验F运行)2 g@10…500 Hz Shoc运行IEC 60068-2-27,A级ESD抗扰度IEC 61000-4-2 6 kV接触放电8 kV空气放电辐射射频抗扰度IEC61000-4-3 10Vm,1 kHz正弦波80%AM,来自80…2000 MHz 10Vm,200 Hz 50%脉冲100%AM@900 MHz 10Vm和200 Hz 50%脉动100%AM@1890 MHz 3Vm,1 Hz正弦波80%AM来自2000…2700 MHz 36罗克韦尔自动化出版物1756-TD001G-EN-P-2013年1月1756 ControlLogix控制器1756 ControlLogix电池每个ControlLogix控制器都配有电池。如果安装1784-CF128工业CompactFlash卡,1756-L6x控制器具有非易失性内存。控制器具有非易失性存储器,可在无电池的情况下使用。

    CE European Union 2004108EC EMC Directive, compliant with: EN 61326-1; Meas.ControlLab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radio communications Ac compliant with: ASNZS CISPR 11; Industrial Emissions Ex European Union 949EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmosphere Protection ’n’ EN 60079-0; General Requirements II 3 G Ex nA IIC T4 X KC Korean Registration of Broadcasting and Communications Equipmen compliant with: Article 58-2 of Radio Waves Ac Clause 3 Rockwell Automation Publication 1756-TD001G-EN-P - January 2013 35 1756 ControlLogix Controllers GuardLogix Extreme-temperature Safety Partner Energy-storage Modules The 1756-L7SPXT extreme-temperature safety partner is shipped with a 1756-SPESMNSEXT energy-storage module installed. Table 41 - Technical Specifications - 1756-L7SPXT Extreme-temperature Safety Partner Energy-storage Modules Attribute 1756-SPESMNSEXT 1756-SPESMNRMXT Description Capacitor energy-storage module for the extreme-temperature safety partner (removable, residual WallClockTime power backup). Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 µJ or less before transporting it into or out of your application. Additionally, you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only. Wait at least 20 minutes for the residual stored energy to decrease to 40 µJ or less before you remove the ESM. Capacitor energy-storage module for the safety extreme-temperature partner (nremovable, secures controller by preventing USB connection an d SD card use). If the SD card is installed prior to insertion of the 1756-ESMNRM module, the SD card remains functiona but t removable. This ESM provides your application an enhanced degree of security. Current draw @ 5.1V DC 300 mA 330 mA rth American temperature code T4A IEC temperature code T4 Enclosure type rating ne (open-style) Table 42 - Environmental Specifications - 1756-L7SPXT Extreme-temperature Safety Partner Energy-storage Modules Attribute 1756-SPESMNSEXT 1756-SPESMNRMXT Temperature, operating IEC 60068-2-1 (Test A Operating Cold), IEC 60068-2-2 (Test B Operating Dry Heat), IEC 60068-2-14 (Test N Operating Thermal Shock) -25…70 °C (-13…158 °F) Temperature, perating IEC 60068-2-1 (Test A Unpackaged perating Cold), IEC 60068-2-2 (Test B Unpackaged perating Dry Heat), IEC 60068-2-14 (Test N Unpackaged perating Thermal Shock) -40…85 °C (-40…185 °F) Temperature, surrounding air, max 70 °C (158 °F) Relative humidity IEC 60068-2-30 (Test D Unpackaged Damp Heat) 5…95% ncondensing Vibration IEC 60068-2-6 (Test F Operating) 2 g @ 10…500 Hz Shoc operating IEC 60068-2-27 (Test E Unpackaged Shock) 30 g Shoc perating IEC 60068-2-27 (Test E Unpackaged Shock) 50 g Emissions CISPR 11 Group 1, Class A ESD immunity IEC 61000-4-2 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3 10Vm with 1 kHz sine-wave 80% AM from 80…2000 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 900 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3Vm with 1 kHz sine-wave 80% AM from 2000…2700 MHz 36 Rockwell Automation Publication 1756-TD001G-EN-P - January 2013 1756 ControlLogix Controllers 1756 ControlLogix Batteries Each ControlLogix controller ships with a battery. The 1756-L6x controllers have nvolatile memory if you install a 1784-CF128 industrial CompactFlash card. With nvolatile memory, the controller can be used without a battery.

    fa405aeea632aa6912154382925a28b_副本.jpg

    MVME5100.jpg

    17.jpg

    20.jpg



    品牌:  Motorola 

    型号:MVME167-031B 

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服