PFCL201 50KN工控备件机器人模块
车票打印、交通灯控制、数据传输。W&M批准的现场总线称重终端获取重量和操作数据。由PLC或PC数据存档控制的经批准的填充或排放W&M。PLC现场总线I/O显示器和键盘亮“彩色屏幕5(13 cm)用于指示重量、操作员提示和校准。带有触觉反馈的密封薄膜键盘,带有用于输入皮重和附加信息的数字键、用于调零和计费的刻度键以及功能键。通过多次分配数字键输入字母字符。称重电子设备C ion的模拟应变计负载连接至称重传感器,入口阻抗43 Ohm–3.3 kOhm(例如适用于8 x 350 Ohm称重传感器),或通过齐纳势垒,入口阻抗87.5 Ohm–3.3kOhm/数字称重传感器的可选接口模块(Flintec RC3D、HBM C16i、Mettler Toledo TBrick、K…)。缩放错误的内部事件日志。使用模拟称重传感器校准刻度:设置为具有1、2或3个量程的单量程或多量程刻度,或设置为多量程刻度。使用测试重量或通过输入称重传感器的额定输出进行校准,选择负载曲线线性化。清除校准顺序所有步骤的操作员提示。通过打印输出将所有校准数据传输至PC或从PC传输。电气连接110–240 VAC,50/60 Hz,12–30 VDC或通过集成电源,装置或12–30 V直流电,通过外部电池供电。工作温度–10°C(+14°F)至+40°C(+104°C),95%相对湿度,无冷凝。接口选项一个SIM插座用于:串行接口,通过RS232或RS485 4线连接PC、打印机、远程显示器或参考标尺。可使用PC工具IT CONFIGURATOR配置打印输出。以太网模块,用于连接到TCP/IP网络或网络打印机。可以通过互联网进行远程诊断。USB模块,用于连接USB打印机或键盘。蓝牙模块,用于连接到支持蓝牙的PC,
printing of ticket, traffic light control, data transmission. W&M approved fieldbus weighing terminal Capturing of weight and operation data. Filling or discharging W&M approved controlled by PLC or PC. data archive. PLC Fieldbus I/O Display and keyboard Bright " color screen 5 (13 cm) for indication of weight and operator prompts and calibration. Sealed membrane keyboard with tactile feedback, with numeric keys for the input of tare weights and additional information, scale keys for zero setting and taring and function keys. Input of alpha characters via multiple assignment of numeric keys. Weighing electronics C ion s analog strain gauge load onnect to scale with cells, entry impedance 43 Ohm–3.3 kOhm (e.g. suitable for 8 x 350 Ohm load cells), or via zener barriers, entry impedance 87.5 Ohm–3.3 kOhm (e.g. suitable for 4 x 350 Ohm load cells), W&M approved resolution up to 10,000 d. Internal resolution 524,000 d, update rate 50 800 , smallest load cell signal 0.33 µV/e. – /s Optional interface modules for digital load cells (Flintec RC3D, HBM C16i, Mettler-Toledo TBrick, K...). Internal event log for scale errors. Calibration Of scales with analog load cells: Setup as single or multiple-range scale with 1, 2 or 3 ranges or as multi-interval scale. Calibration with test weights or through entry of rated output of load cell(s), option for the linearization of the load curve. Clear operator prompts for all steps of calibration sequence. Transmission of all calibration data to/from PC with printout. Electrical connection 110–240 VAC, 50/60 Hz 12–30 VDC or via integrated power supply , unit or 12–30 VDC . for power supply via external battery Operating temperature –10 °C (+14 °F) to +40 °C (+104 °F), 95 % relative humidity, non-condensing. Interface options One SIM socket for: Serial interface to connect a PC, printer, remote display or reference scale via RS232 or RS485 4-wire. Printout configurable with PC tool IT CONFIGURATOR. Ethernet module to connect to TCP/IP networks or a network printer. Remote diagnosis is possible via internet. USB module to connect a USB printer or keyboard. Bluetooth module to connect to a Bluetoothenabled PC,