PFCL201CE 5.0KN工业自动化卡件
-I 111976 415 V 50/60 Hz时的正常开关容量50 kA零件编号价格标准包注释条款编号见价目表IEC/EN 60947-2可调过载释放I r 0.8–1 x I n(出厂时0.8 x I n)通过主极的主极设置I r在中性极上进行设置。可调短路脱扣器I I 6–10 x I r( M…3、LZM、…4伊顿公司C 1000/630-I 111987 415 V 50/60 Hz时正常开关容量50 kA零件号。价格标准包装说明条款编号见价目表IEC/EN 60947-2可调过载释放I r 0.5–1 x I n(出厂时0.8 x I n)中性极设置通过主极的主极设置I r实现。R、 m.s.值测量和“热记忆”可调短路脱扣器I I LZM…3-4-AE630-I:2–8 x I n(出厂时为6 x I n)LZM…4-4-AE…-I:2–12 x I n,LZM…-4-AE…/…-I具有60%或100%过载和短路保护的4极12开关隔离开关3极、4极订购LN1…、LN2…、LN3…、LN4…伊顿公司CA012002EN 3极4极额定电流=短路零件号价格零件号价格标准额定不间断保护最大值。条款编号见价格条款编号见定价包电流熔断器列表gL特性I n=I u A A隔离开关可通过分流或欠压释放端子标准远程跳闸,端子螺钉作为附件63 125 LN1- 注释主开关特性,包括符合IEC/EN 60204和VDE 0113的正驱动隔离特性符合IEC/EEN 60947-3和VDE 0660端子意外接触保护符合IEC 100注释公司CA012002EN 14连接类型订购LZM1伊顿公司 接线盒标准设备LZM1(-4)三极和四极铜电缆1 x 10–701)1 x 8–2/0 LN1(-4)2 x 6–25 2 x 9–4螺纹连接LZM135 1 x 8–2 2 x 10–35 2 x 8–3最大电缆连接用于终端容量区域导体类型mm²AWG/kcmil隧道终端LZM1(-4)三极和四极铜电缆1 x 16–95 1 x 6–3/0 LN1(-4)铝电缆2 x 6–25–注1)根据电缆制造商,最多可连接95 mm²。盖子–LZM1(-4)3极LN1(-4)–4极连接类型15订购LZM1伊顿公司CA012002EN零件号。价格终端容量条款编号(见价格标准包时)单独订购的注释列出铜带(铜母线宽度x宽度x段厚度)mm mm 2 x 9 x 0.8 NZM1-XKC 1个9 x 9 x 0.8260015 NZM1-4-XKC 1个267075所有开关LZM1和LN1的标准连接。带螺纹连接的断路器转换套件。类型包含3或4极开关侧的零件。安装在开关外壳内,最小12 x 5 NZM1-XKS 1个,最大16 x 5 260019最小12 x 6 NZM1-4-XKS 1个,最多16 x 5 266725类型包含位于3或4极断路器顶部或底部的端子零件。安装在开关外壳外部。必须安装NZM1(-4)-XKSA盖(提供)。NZM1-XKA 1个266730 NZM1-4-XKA 1个266731型包含
-I 111976 Normal switching capacity at 415 V 50/60 Hz 50 kA Part number Price standard package Note clause number See the price list IEC/EN 60947-2 Adjustable overload release I r 0.8 – 1 x I n (0.8 x I n at the factory) is set on the neutral pole through the main pole setting I r of the main pole. Adjustable short-circuit release I I 6 – 10 x I r (M... 3, LZM,... 4 Eaton C 1000/630-I 111,987 415 V 50/60 Hz normal switching capacity 50 kA part number. See the price list IEC/EN 60,947-2 Adjustable overload release I r 0.5 – 1 x I n (0.8 x I n when leaving the factory). The neutral pole setting is realized by the main pole setting I r of the main pole. R. M.s. value measurement and "thermal memory" adjustable short circuit release I I LZM... 3-4-AE630-I: 2 – 8 x I n (6 x I n when leaving the factory) LZM... 4-4-AE... - I: 2 – 12 x I n, LZM... - 4-AE.../... - I 4-pole 12 switch disconnector with 60% or 100% overload and short circuit protection 3-pole, 4-pole order LN1..., LN2..., LN3 LN4... EATON CA012002EN 3-pole 4-pole rated current=short circuit part number price part number price standard rated maximum uninterrupted protection. See the list of current fuses in the pricing package for the item number. gL characteristic I n=I u A A disconnector can be remotely tripped through the standard shunt or undervoltage release terminal. The terminal screw is as Annex 63 125 LN1 - Note the characteristics of the main switch, Including forward drive isolation characteristics according to IEC/EN 60204 and VDE 0113 Accidental contact protection of terminals according to IEC/EEN 60947-3 and VDE 0660 Accidental contact protection according to IEC 100 Annotation company CA012002EN 14 Connection type Order LZM1 junction box standard equipment LZM1 (- 4) Three pole and four pole copper cable 1 x 10 – 701) 1 x 8 – 2/0 LN1 (- 4) 2 x 6 – 25 2 x 9 – 4 threaded connection LZM135 1 x 8 – 2 2 x 10 – 35 2 x 8 – 3 maximum cable connection for terminal capacity area Conductor type mm ² AWG/kcmil tunnel terminal LZM1 (- 4) three pole and four pole copper cable 1 x 16 – 95 1 x 6 – 3/0 LN1 (- 4) aluminum cable 2 x 6 – 25 – Note 1) According to the cable manufacturer, up to 95 mm can be connected ²。 Cover – LZM1 (- 4) 3 pole LN1 (- 4) – 4 pole connection type 15 Order LZM1 Eaton CA012002EN part number. The price terminal capacity clause number (see the price standard package) The note ordered separately lists the copper strip (copper bus width x width x section thickness) mm mm 2 x 9 x 0.8 NZM1-XKC 1 piece 9 x 9 x 0.8260015 NZM1-4-XKC 1 piece 267075 The standard connection of all switches LZM1 and LN1. Breaker changeover kit with threaded connection. The type contains parts on the 3 or 4 pole switch side. Mounted in the switch housing, minimum 12 x 5 NZM1-XKS 1, maximum 16 x 5 260019 minimum 12 x 6 NZM1-4-XKS 1, maximum 16 x 5 266725 type includes terminal parts located at the top or bottom of 3 or 4-pole circuit breakers. Installed outside the switch housing. The NZM1 (- 4) - XKSA cover (supplied) must be installed. One NZM1-XKA, 266730, one NZM1-4-XKA, 266731