PFSK152REP 3BSE018877R1模拟量输入模块
公告140M电机保护断路器2-4 www.ab.com/catalogs首选可用性目录。编号为粗体。出版物A117-CA001A-EN-P!1 2 3 4 5 6 7 8 9 10 11 12 13目录号说明目录。否。本节中给出的示例仅供参考。该基本解释不应用于产品选择;并非所有组合都会产生有效的目录号。140M–C–2–E–A63–KN–CC–GJ a bcde f gh d保护类型代码描述E调节热/固定磁场(13…14 x In)T调节热/定磁场(16…20 x In)h紫外线和并联跳闸参见第2-36页g辅助/跳闸触点参见第2-36f页其他参见第2-38 f,g,h工厂安装选项e电流范围代码描述示例A A=.10 A16=0.16 B B=1.0 B16=1.6 C C=10 C16=16 D D=100 D16=160 e e=1000 E16=1600 C中断额定值/断开容量代码描述2正常断开8高断开B框架尺寸和额定值代码描述C 32 A D 32 A F 45 A I 205 A J 250 A L 400 A和600 A公告编号代码描述140M电机保护断路器(MPCB)公告140M电机保护断路器2-2 www.ab.com/catalogs首选可用性目录。编号为粗体。出版物A117-CA001A-EN-P!1 2 3 4 5 6 7 8 9 10 11 12 13公告140M电动机保护断路器公告140M电机保护断路器为单个电动机负载提供短路和过载保护。工厂安装的内部配件使安装和布线变得容易。一般信息目录产品选择-电机保护断路器…………..2-8近似尺寸………..2-51电流范围0.1……630 A UL列出的电机负载− 短路保护− 过载保护可见跳闸指示高电流限制高开关容量认证标准符合性电机保护断路器可提供以下保护和控制功能。断开电机分支电路分支电路、短路保护(磁保护)过载保护(热保护)开关(手动)在北美,电气规范要求单个电机分支电路由UL/CSA认证的保险丝、断路器或自保护组合电机控制器保护。140M-C、D和F框架:140M-C和D框架电机保护断路器可能有两个ULus列表——作为手动、自保护组合电机控制器和手动电机控制器(具有电机断开和组安装的可选批准)。当UL/CSA列为手动自保护组合电机控制器时,140M电机保护断路器提供了保护和控制单个电机分支电路的所有必要的NEC/CEC要求,无需额外的保护装置。在某些较高的电压和电流(尤其是600V)下,少数140M-C、D和F框架设备仅被UL/CSA列为手动电机控制器(具有电机断开和组安装的可选批准)。在NEC/CEC集团安装中,这些设备必须按照要求使用上游分支电路、短路保护装置(BCPD)的适当规则应用。各电动机保护断路器的具体额定值见第2-18页的表。140-CMN框架:140-CMN框架电机保护断路器经UL认证/CSA认证为手动电机控制器(具有电机断开和组安装的可选批准)。在NEC/CEC集团安装中,这些设备必须按照要求使用上游分支电路、短路保护装置(BCPD)的适当规则应用。各电动机保护断路器的具体额定值见第2-18页的表。140M-I、J和L框架:140M-I和J框架电机保护断路器被列为断路器,如第2-9页表格所示。在这些情况下,140M电机保护断路断路器提供了保护和控制单个电机分支电路的所有必要的NEC/CEC要求,无需额外的保护装置。有关电机保护断路器正确应用的更多详细信息,请参阅以下页面的图表。IEC/EN 60947-1、-2、-4-1、-5-1Bulletin 140M Motor Protection Circuit Breakers 2-4 www.ab.com/catalogs Preferred availability cat. nos. are bold. Publication A117-CA001A-EN-P ! 1 2 3 4 5 6 7 8 9 10 11 12 13 Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid catalog number. 140M – C – 2 – E – A63 – KN – CC – GJ a bcde f gh d Protection Type Code Description E Adj Thermal/ Fixed Mag (13…14 x In) T Adj Thermal / Fixed Mag (16...20 x In) h UV and Shunt Trips See page 2-36 g Aux/Trip Contacts See page 2-36 f Miscellaneous See page 2-36 f, g, h Factory-Installed Options e Current Range Code Description Example A A = .10 A16 = 0.16 B B = 1.0 B16 = 1.6 C C = 10 C16 = 16 D D = 100 D16 = 160 E E = 1000 E16 = 1600 c Interrupting Rating / Breaking Capacity Code Description 2 Normal Break 8 High Break b Frame Size and Rating Code Description C 32 A D 32 A F 45 A I 205 A J 250 A L 400 A and 600 A a Bulletin Number Code Description 140M Motor Protection Circuit Breakers (MPCBs) Bulletin 140M Motor Protection Circuit Breakers 2-2 www.ab.com/catalogs Preferred availability cat. nos. are bold. Publication A117-CA001A-EN-P ! 1 2 3 4 5 6 7 8 9 10 11 12 13 Bulletin 140M Motor Protection Circuit Breakers The Bulletin 140M Motor Protection Circuit Breakers provide short circuit and overload protection for individual motor loads. Factoryinstalled internal accessories make installation and wiring easy. General Information Table of Contents Product Selection — Motor Protection Circuit Breakers.......... 2-8 Approximate Dimensions................... 2-51 Current Range 0.1…630 A UL Listed for Motor Loads − Short Circuit Protection − Overload Protection Visible Trip Indication High Current Limiting High Switching Capacity Certifications Standards Compliance Motor Protection Circuit Breakers may provide the following protective and control functions. Disconnect for Motor Branch Circuit Branch-Circuit, Short-Circuit Protection (Magnetic Protection) Overload Protection (Thermal Protection) Switching (Manual) In North America, electrical codes require that an individual Motor Branch Circuit be protected by a UL/CSA Listed Fuse, Circuit Breaker or Self-Protected Combination Motor Controller. 140M-C, D and F Frames: The 140M-C, D and F frame Motor Protection Circuit Breakers may have 2 cULus Listings – as Manual, Self-Protected Combination Motor Controllers and as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). When UL/CSA listed as Manual, Self-Protected Combination Motor Controllers, the 140M Motor Protection Circuit Breakers provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. At some higher voltages and currents (particularly at 600V), a few of the 140M-C, D and F frame devices are only UL/CSA Listed as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on page 2-18 for the specific ratings of each Motor Protection Circuit Breaker. 140-CMN Frame: The 140-CMN frame Motor Protection Circuit Breakers are UL Listed/CSA Certified as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on page 2-18 for the specific ratings of each Motor Protection Circuit Breaker. 140M-I, J and L Frames: The 140M-I, J and L frame Motor Protection Circuit Breakers are cULus Listed as Circuit Breakers as shown in the table on page 2-9. In these cases, the 140M Motor Protection Circuit Breakers provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. For further details on the proper application of Motor Protection Circuit Breakers, please see the diagrams on the following pages. IEC/EN 60947-1, -2, -4-1, -5-1