PFTL101A 0.5KN 3BSE004166R1系统备件
,股份有限公司保留所有权利。美国印刷尺寸[mm(in.)]安装安装安装后,用轻油或喷雾(例如WD-40®)或适合应用的替代产品润滑代码筒组件。检查操作是否正确。图1显示了面板切口和螺钉尺寸建议。图1-安装图2-装配图3-操作图4-信号输入图5-所示图表,带无键90(3.54)120(4.72)100(3.94)50(1.97)150(5.90)116(4.57)160(6.30)DC类型:11 W AC类型:17V AC 6 x 4.5(0.18)90(3.52)82(3.23)70(2.75)70(2.65)132(5.20)6 x M4电阻器面板断流器R4最大2.5(0.10)1 2 3顶部安装的装置,带翻盖铰链。440T-MSRUE10 440T-MSUE11 440T-MSRE13 440T-MSRU 12 440T-MSRRUE22 440T-MSROE14 440T-MS鲁E14 440T-MSRUE13 440T-MS鲁E14 440T-MSRUE14 440T MSRUE24 440T-MS RUE24 440 T-MSRUE20 440T-MSR UE34 440T-MSURE35 440T-MSR15关闭电源22 2321 24信号输入电磁阀监视器电磁阀监视器1 3 5 7 4 6 8 1 3 5 2 4 6 8 3 5 7 9 6 8 10 1 2 11技术数据CompactLogix通信模块规格1768 CompactLogix目录号1768-ENBT、1768-EWEB、1768-CNB、1768-CN BR 1769 Compact I/O目录号1769-SDN、1769-ADN、,1769-AENTR主题页网络2 EtherNet/IP网络5 Stratix交换机7 ControlNet网络9 DeviceNet网络12串行网络14 DH-485网络15 2罗克韦尔自动化出版物1769-TD007D-EN-P-2014年5月CompactLogix通信模块规范网络您可以配置您的系统以在一系列设备和计算平台之间进行信息交换系统。为满足您需要的网络选择具有集成通信的CompactLogix控制器或适当的通信设备。应用网络1769-L23x控制器1769-L3x控制器1768-L4x、1768-L4xS控制器CompactLogix 5370 L1控制器CompactLogic 5370 L2控制器CompactLogic 5370 L3控制器•工厂管理(物料处理)•在单个、,高速网络•包含商业技术(如IP视频)•Internet/Intranet连接EtherNet/IP网络•1769-L23EQB1B控制器•1769-L33EQBFC1B控制器•176 9-L32E控制器•1769L35E控制器•1768-ENBT网桥•1768-EWEB web服务器•1769-L16ER控制器•1769-L18ER控制器•176 9-L18ERM控制器•1769-024ER控制器•1769-L27ERM控制器•1769-L30ER控制器•1769L30ERM控制器•176 9-L33ER控制器•1769-L33ERM控制器•1769 L36ERM控制器•控制器和I/O设备之间的时间关键数据高速传输•确定性和可重复数据传输•介质冗余•本质安全•冗余控制器系统ControlNet网络不可用•1769-L32C控制器(非冗余介质)•1769-L35CR控制器(冗余介质,无需通过I/O模块进行连接•根据需要发送数据•更多的诊断功能可改善数据收集和故障检测•与传统的、,硬接线系统DeviceNet网络•1769-SDN扫描仪•1769-ADN适配器不可用1769-SDN扫描仪•调制解调器•监控和数据采集(SCADA)串行网络•控制器上的内置串行端口•1769-ASCII模块不可用连接到现有DH-485网络DH-485网带1761-NET-AIC链接设备的内置串行接口不可用罗克韦尔自动化出版物1769-TD007D-EN-P-2014年5月3 CompactLogix通信模块规范表1-环境规范-1768通信模块属性1768-ENBT、1768-EWEB 1768-CNB、1768-CNBR温度,运行IEC 60068-2-1(测试Ad,运行低温)、IEC 60068-2-2(测试Bd,运行干热),IEC 60068-2-14(试验Nb,工作热冲击)0…60°C(32…140°F)环境空气温度,最高60°C,IEC 60068-2-14(试验Na,未包装非工作热冲击)-40…85°C(-40…185°F)相对湿度IEC 60068-2-30(试验Db,未包装的非工作湿热)5…95%非冷凝振动IEC 60068-2-6(试验Fc,工作)5 g@10…500 Hz冲击,工作IEC 60068-2-27(试验Ea,未密封冲击)30 g冲击,非工作IEC 60068-2-27(试验Ea,无包装冲击)50 g发射CISPR 11(IEC 61000-6-4):第1组,A类CISPR 11
, Inc. All rights reserved. Printed in the U.S.A. Dimensions [mm (in.)] Installation Upon installation, lubricate the code barrel assembly with light oil or spray (for example, WD-40®) or alternative product suitable for application. Check for correct operation. Figure 1 shows the panel cutout and screw size recommendation. Figure 1 - Mounting Figure 2 - Assembly Figure 3 - Operation Figure 4 - Signal Input Figure 5 - Diagrams Shown with Key Free 90 (3.54) 120 (4.72) 100 (3.94) 50 (1.97) 150 (5.90) 116 (4.57) 160 (6.30) DC Types: 11 W AC Types: 17V AC 6 x 4.5 (0.18) 90 (3.54) 82 (3.23) 70 (2.75) 70 (2.75) 132 (5.20) 6 x M4 Resistorx Panel Cutout R4 max. 2.5 (0.10) 1 2 3 Installed units with flip cap hinge on top. 440T-MSRUE10 440T-MSRUE11 440T-MSRUE13 440T-MSRUE12 440T-MSRUE22 440T-MSRUE14 440T-MSRUE20 440T-MSRUE33 440T-MSRUE46 440T-MSRUE23 440T-MSRUE44 440T-MSRUE24 440T-MSRUE30 440T-MSRUE34 440T-MSRUE35 440T-MSRUE40 Power Off Power On 22 2321 24 Signal Input Solenoid Monitor Solenoid Monitor 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 3 5 7 9 4 6 8 10 1 2 11 12Technical Data CompactLogix Communication Modules Specifications 1768 CompactLogix Catalog Numbers 1768-ENBT, 1768-EWEB, 1768-CNB, 1768-CNBR 1769 Compact I/O Catalog Numbers 1769-SDN, 1769-ADN, 1769-AENTR Topic Page Networks 2 EtherNet/IP Network 5 Stratix Switches 7 ControlNet Network 9 DeviceNet Network 12 Serial Network 14 DH-485 Network 15 2 Rockwell Automation Publication 1769-TD007D-EN-P - May 2014 CompactLogix Communication Modules Specifications Networks You can configure your system for information exchange between a range of devices and computing platforms and operating systems. Select a CompactLogix controller with integrated communication or the appropriate communication device for the networks that meet your needs. Application Network 1769-L23x Controller 1769-L3x Controller 1768-L4x, 1768- L4xS Controller CompactLogix 5370 L1 controllers CompactLogix 5370 L2 controllers CompactLogix 5370 L3 controllers • Plant management (material handling) • Configuration, data collection, safety, and control on a single, high-speed network • Inclusion of commercial technologies (such as video over IP) • Internet/Intranet connection EtherNet/ IP network • 1769-L23EQB1B controller • 1769-L23EQBFC1B controller • 1769-L32E controller • 1769-L35E controller • 1768-ENBT bridge • 1768-EWEB web server • 1769-L16ER controller • 1769-L18ER controller • 1769-L18ERM controller • 1769-L24ER controller • 1769-L27ERM controller • 1769-L30ER controller • 1769-L30ERM controller • 1769-L33ER controller • 1769-L33ERM controller • 1769-L36ERM controller • High-speed transfer of timecritical data between controllers and I/O devices • Deterministic and repeatable data delivery • Media redundancy • Intrinsic safety • Redundant controller systems ControlNet network Not available • 1769-L32C controller (nonredundant media) • 1769-L35CR controller (redundant media) • 1768-CNB bridge (nonredundant media) • 1768-CNBR bridge (redundant media) Not available • Connections of low-level devices directly to plant floor controllers, without interfacing them through I/O modules • Data sent as needed • More diagnostics for improved data collection and fault detection • Less wiring and reduced start-up time than a traditional, hard-wired system DeviceNet network • 1769-SDN scanner • 1769-ADN adapter Not available 1769-SDN scanner • Modems • Supervisory control and data acquisition (SCADA) Serial network • Built-in serial port on the controller • 1769-ASCII module Not available Connections to existing DH-485 networks DH-485 network Built-in serial port with a 1761-NET-AIC linking device Not available Rockwell Automation Publication 1769-TD007D-EN-P - May 2014 3 CompactLogix Communication Modules Specifications Table 1 - Environmental Specifications - 1768 Communication Modules Attribute 1768-ENBT, 1768-EWEB 1768-CNB, 1768-CNBR Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) 0…60 °C (32…140 °F) Temperature, surrounding air, max 60 °C (140 °F) Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) -40…85 °C (-40…185 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Nonoperating Damp Heat) 5…95% noncondensing Vibration IEC 60068-2-6 (Test Fc, Operating) 5 g @ 10…500 Hz Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock) 30 g Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock) 50 g Emissions CISPR 11 (IEC 61000-6-4): Group 1, Class A CISPR 11 (IEC 61000-6-4): Class A ESD Immunity IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges IEC