PFTL101A 3BSE004166R1控制器模块
(9 mm)断开锁定最大5/16 in。(8 mm)锁钩环或搭扣。搭扣不应超过5/16英寸。(8 mm),否则会损坏防护装置。EMC发射水平传导射频发射10V rms通信电缆10V rms(PE)150 KHz…80 MHz辐射发射A类EMC抗扰度水平静电放电4 kV接触和8 kV空气射频电磁场10V/m,80 KHz…1 GHz 3V/m,1.4 GHz…2.0 GHz 1V/m,2.0 GHz…2.7 GHz快速瞬变2 kV(电力)2 kV(PE)1 kV(通信和控制)浪涌瞬变1 kV(12)L-L,2 kV(2)L-N(接地)过载额定值过载电流范围280_-_-10A-*0.24…1.2 A 280_-_____-10B-*0.5…2.5 A 280_/_____-10C-*1.1…5.5 A 280__-_-10D-*3.2…16 A跳闸等级10、15、20跳闸额定值FLC设置的120%极数3标准符合UL 508;CSA C22.2,第14号;EN/IEC 60947-4;EN/IEC 60947-4-1;CE标志符合低压2006/95/EC;EMC指令2004/108/EC;CCC;EtherNet/IP的ODVA;ODVA for DeviceNet认证cULus(文件编号E3125,指南NLDX,NLDX7)公告280E/281E ArmorStart®分布式电机控制器出版物280E-SG001B-EN-P 11 EtherNet/IP版本-控制和I/O电源要求A1/A2✶ A3/A2 A1/A2✶ A3/A2 A3/A2‡单元W/O HOA W/HOA控制电压电压24V DC模块浪涌电流0.92 0.30 1.09 0.125 0.295模块稳定电流0.06 0.30 0.23 0.125 0.295-总控制功率(拾取)瓦22.08 7.20 26.16 3.00 7.08总控制功率✶ 将输出功率要求(最大1 A)添加到A1/A2。将输入功率要求(最高200 mA)添加到A3/A2。‡如果A1电源断开。UL/NEMA IEC输入额定值来源于控制电路-A3/A2额定工作电压24V DC输入接通状态电压范围10…26V DC输入接通电压范围3.0 mA@10V DC 7.2 mA@24V DC输入断开状态电压范围0…5V DC输入断状态电流<1.5 mA输入滤波器-软件可从0…64 ms切换到打开可从0到64 ms,以1 ms为增量打开到关闭可从0至64 ms,在1 ms内设置增加输入兼容性N/A IEC 1+输入数量4传感器电源电压状态仅11…26.4V DC来自DeviceNet电流每个输入最大可用50 mA,控制电路提供的200 mA总输出额定值-A1/A2额定工作电压26.4V DC额定绝缘电压250V电介质耐受1500V AC(UL)2000V AC(IEC)控制电路类型固态电源输出电流24V DC常规热电流Ith各0.5 A,1 A最大组合触点类型常开(N.O.)触点数量2负载类型电阻或光感应浪涌抑制集成二极管,箝位@35V DC热保护集成短路和过电流保护最大循环速率30次/分钟电容和电感负载最大阻断电压35V DC最大开态电压@最大输出1.5V DC最大关态泄漏电流10μA设备级环(DLR)基于信标的性能,包括IEEE 1588端到端透明时钟最大节点50对于50节点网络EtherNet端口2,故障恢复环恢复时间小于3ms,4针内螺纹M12连接器端口带有2个端口IP地址的嵌入式交换机默认DHCP超时30秒通信速率10/100 Mbs,自动协商半双工和全双工数据通过TCP和UDP Web服务器嵌入式Web服务器安全登录和密码可配置电子邮件支持简单邮件传输协议(SMTP)配置状态、诊断、,和配置选项卡设备连接支持计划(1级)和非计划(3级和UCMM)连接6-3级连接2-1级(1个独占所有者,1个仅输入和1个仅侦听)连接支持规范公告280E/281E ArmorStart®分布式电机控制器12出版物280E-SG001B-EN-P规范10%满载电流近似跳闸时间[s]冷热等级20%满载电流近似跳闸时间[s]低温等级15%满载电流近似脱扣时间[s]高温电机过载跳闸曲线电机OL电流参数提供10、15和20级过载保护。环境不敏感是过载电子设计中固有的。公告280E/281E ArmorStart®分布式电机控制器出版物280E-SG001B-EN-P 13近似尺寸尺寸单位为毫米(英寸)。尺寸不用于制造目的。
(9 mm) Disconnect Lock Out Maximum of 5/16 in. (8 mm) lock shackle or hasp. The hasp should not exceed 5/16 in. (8 mm) when closed, or damage will occur to disconnect guard. EMC Emission Levels Conducted Radio Frequency Emissions 10V rms Communication cables 10V rms (PE) 150 KHz…80 MHz Radiated Emissions Class A EMC Immunity Levels Electrostatic Discharge 4 kV contact and 8 kV Air Radio Frequency Electromagnetic Field 10V/m, 80 KHz…1 GHz 3V/m, 1.4 GHz…2.0 GHz 1V/m, 2.0 GHz…2.7 GHz Fast Transient 2 kV (Power) 2 kV (PE) 1 kV (Communications and control) Surge Transient 1 kV (12) L-L, 2 kV (2) L-N (earth) Overload Rating Overload Current Range 280_-___-10A-* 0.24…1.2 A 280_-___-10B-* 0.5…2.5 A 280_-___-10C-* 1.1…5.5 A 280_-___-10D-* 3.2…16 A Trip Classes 10, 15, 20 Trip Rating 120% of FLC setting Number of poles 3 Standards Compliance UL 508; CSA C22.2, No. 14; EN/IEC 60947-4; EN/IEC 60947-4-1; CE Marked per Low Voltage 2006/95/EC; EMC Directive 2004/108/EC; CCC; ODVA for EtherNet/IP; ODVA for DeviceNet Certifications cULus (File No. E3125, Guides NLDX, NLDX7) Bulletin 280E/281E ArmorStart® Distributed Motor Controller Publication 280E-SG001B-EN-P 11 EtherNet/IP Version - Control and I/O Power Requirements A1/A2✶ A3/A2 A1/A2✶ A3/A2 A3/A2‡ Units W/O HOA W/ HOA Control Voltage Volts 24V DC Module Inrush Amps 0.92 0.30 1.09 0.125 0.295 Module Steady Amps 0.06 0.30 0.23 0.125 0.295 Total Control Power (Pick Up) Watts 22.08 7.20 26.16 3.00 7.08 Total Control Power (Running) Watts 1.44 7.20 5.52 3.00 7.08 ✶ Add power requirements for outputs (1 A max.) to A1/A2. Add power requirements for inputs (200 mA max.) to A3/A2. ‡ If A1 power is disconnected. UL/NEMA IEC Input Ratings Sourced from control circuit - A3/A2 Rated Operation Voltage 24V DC Input On-State Voltage Range 10…26V DC Input On-State Current 3.0 mA @ 10V DC 7.2 mA @ 24V DC Input Off-State Voltage Range 0…5V DC Input Off-State Current <1.5 mA Input Filter — Software Selectable Off to On Settable from 0…64 ms in 1 ms increments On to Off Settable from 0…64 ms in 1 ms increments Input Compatibility N/A IEC 1+ Number of Inputs 4 Sensor Source Voltage Status Only 11…26.4V DC from DeviceNet Current Available 50 mA max. per input, 200 mA total Output Ratings Sourced from Control Circuit - A1/A2 Rated Operation Voltage 26.4V DC Rate Insulation Voltage 250V Dielectric Withstand 1500V AC (UL) 2000V AC (IEC) Type of Control Circuit Solid state sourcing output Type of Current 24V DC Conventional Thermal Current Ith 0.5 A each, 1 A max. combined Type of Contacts Normally open (N.O.) Number of Contacts 2 Load Types Resistive or light inductive Surge Suppression Integrated diode, clamps @ 35V DC Thermo-Protection Integrated short circuit and over current protection Maximum Cycle Rate 30 operations/minute capacitive and inductive loads Maximum Blocking Voltage 35V DC Maximum On-State Voltage @ Maximum Output 1.5V DC Maximum Off-State Leakage Current 10 μA Device Level Ring (DLR) Beacon-based performance including IEEE 1588 end to end transparent clock Maximum Nodes 50 Fault Recovery Ring recovery time is less than 3 ms for a 50 node network EtherNet Port 2 D-coded, 4-pin female M12 connecters Ports Embedded switch with 2 ports IP Address DHCP enabled by default DHCP Timeout 30 seconds Communication Rate 10/100 Mbs with auto negotiate half duplex and full duplex Data Transported over both TCP and UDP Web Server Embedded web server Security Login and password configurable E-mail Support Simple Mail Transfer Protocol (SMTP) Configuration Status, diagnostics, and configuration tabs Device Connections Supports scheduled (Class 1) and unscheduled (Class 3 & UCMM) connections 6 - Class 3 connections 2 - Class 1 (1 exclusive owner, 1 input only and 1 listen only) connections are supported Specifications Bulletin 280E/281E ArmorStart® Distributed Motor Controller 12 Publication 280E-SG001B-EN-P Specifications Class 10 % Full Load Current Approximate Trip Time [s] Cold Hot Class 20 % Full Load Current Approximate Trip Time [s] Cold Hot Class 15 % Full Load Current Approximate Trip Time [s] Cold Hot Motor Overload Trip Curves Motor OL current parameter provides class 10,15, and 20 overload protection. Ambient insensitivity is inherent in the electronic design of the overload. Bulletin 280E/281E ArmorStart® Distributed Motor Controller Publication 280E-SG001B-EN-P 13 Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.