PFTL101A-1.0 3BSE004166R1DCS模块卡件
彩色线规mm2(AWG)连接器引脚1电源黑色2.59(10)1 2电源黑色2.58(10)2 3电源黑色2.56(10)3 4制动器黑色1.29(16)4 5恒温器黑色1.26(16)5 6制动器黑色1.26#6绿色/黄色电线#9屏蔽连接器引脚出版物1326-IN030A-EN-P-2007年5月4 PN-13137取代出版物1326A-IN030A-EN-P–2007年5月份版权所有©2007 Rockwell Automation,Inc.。保留所有权利。美国印制电缆弯曲半径表和图表描述了电缆的最小弯曲半径。弯曲半径是允许的最紧(最小)曲率,不会对电缆造成潜在损坏。Allen-Bradley、Rockwell Automation和TechConnect是罗克韦尔自动化股份有限公司的商标。不属于罗克韦尔自动化的商标是其各自公司的财产。弯曲半径BR电机电力电缆目录号1326-CPB1T-EL-xxx 1326-CPC1T-EL-xxxBR mm(in.)(1)104.1(4.1)160.2(6.3)(2)弯曲半径(BR)是电缆组件的规定最小弯曲半径。对于标准电缆,BR是一次性柔性应用。BR可能因用户制造的电缆而异。挠性电缆具有更高的BR,以承受挠性应用。1出版物1326-IN030A-EN-P-2007年5月安装说明1326特殊应用电缆目录号1326-CPB1T-L、1326-CPC1T-L关于本出版物本文件包含带有飞线的电缆的安装信息。飞线允许客户确定电缆终端的类型。本表列出了可用的1326根特殊应用电缆及其废弃电缆。此电缆取代此电缆。1326-CPB1T-L-xxx 1326-CPB1-xxx、1326-CPB 1-L-xxx、1326-CP B1T-xxx 1326-CP C1T-L-xxx、132 6-CPC1-xxx、132 6-CP C1-L-xxx、134 6-CPC1T-xxx注意驱动器上的直流母线电容器
Color Gauge mm2 (AWG) Connector Pin 1 Power Black 2.59 (10) 1 2 Power Black 2.59 (10) 2 3 Power Black 2.59 (10) 3 4 Brake Black 1.29 (16) 4 5 Thermostat Black 1.29 (16) 5 6 Brake Black 1.29 (16) 6 Overall shield Shield 2.05 (12) 7 8 GND Green/Yellow 2.05 (12) 8 9 Thermostat Black 1.29 (16) 9 Overall shield Braid N/A Connected to shell 1 2 3 4 5 6 8 9 7 Wire #1 Wire #2 Wire #3 Wire #4 Wire #5 Wire #6 Green/Yellow Wire#9 Shield Connector Pin Publication 1326-IN030A-EN-P - May 2007 4 PN-13137 Supersedes Publication 1326A-IN030A-EN-P - May 2007 Copyright © 2007 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. Cable Bend Radius The table and diagram depict the minimum bend radius for cables. Bend radius is the tightest (minimum) curvature allowed without potential damage to the cable. Allen-Bradley, Rockwell Automation, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are the property of their respective companies. Bend Radius BR Motor Power Cable Catalog Number 1326-CPB1T-EL-xxx 1326-CPC1T-EL-xxx BR mm (in.) (1) 104.1 (4.1) 160.2 (6.3) (1) Bend radius (BR) is the specified minimum bend radius for cable assemblies. For standard cable, BR is a one-time flex application. BR may vary on user-fabricated cables. Flex-rated cables have a much higher BR to withstand flex applications.1 Publication 1326-IN030A-EN-P - May 2007 Installation Instructions 1326 Special Application Cables Catalog Numbers 1326-CPB1T-L, 1326-CPC1T-L About This Publication This document contains installation information for cables that have flying leads. The flying leads allow the customer to determine the type of cable terminations. This table lists available 1326 special application cables and the cables they obsolete. This cable replaces this cable. 1326-CPB1T-L-xxx 1326-CPB1-xxx, 1326-CPB1-L-xxx, 1326-CPB1T-xxx 1326-CPC1T-L-xxx 1326-CPC1-xxx, 1326-CPC1-L-xxx, 1326-CPC1T-xxx ATTENTION DC bus capacitors on a drive re