您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

PFTL101A-2.0 3BSE004172R1工控模块系统备件

PFTL101A-2.0 3BSE004172R1工控模块系统备件

PFTL101A-2.0 3BSE004172R1工控模块系统备件下图显示了通过螺钉连接并突出穿过法兰和导电壁(例如金属柜)的隔板连接器的侧视图。前视图显示了连接的隔板连接器的引脚穿过墙壁。AB配对导电(金属)壁连接器二次成型外形,黑色pvc B ED C 18-1 I A G F J H前视图侧视图17出版物1326A-2.11-1998年5月通过机柜壁安装隔板为安装隔板连接器准备机柜壁:1.确...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

PFTL101A-2.0 3BSE004172R1工控模块系统备件

    PFTL101A-2.0 3BSE004172R1工控模块系统备件


    下图显示了通过螺钉连接并突出穿过法兰和导电壁(例如金属柜)的隔板连接器的侧视图。前视图显示了连接的隔板连接器的引脚穿过墙壁。AB配对导电(金属)壁连接器二次成型外形,黑色pvc B ED C 18-1 I A G F J H前视图侧视图17出版物1326A-2.11-1998年5月通过机柜壁安装隔板为安装隔板连接器准备机柜壁:1.确定将安装隔板连接器的机柜壁区域。2.标记四个安装孔和中心连接器开口的位置。3.钻四个安装孔和大中心开口。4.从1326-CPB1-E-xxx、1326-CPB1T-E-xxx、1326-CPR1-E-xxx或1326-CPC1T-E-xxx电缆的隔板法兰将接触的机柜壁内表面刮去任何油漆。注:所有B系列电缆连接器都经过黑色、高导电性钴涂层处理。不要刮擦涂层。重要提示:金属对金属连接必须符合CE合规标准。5.从1326 CCU EL xxx、1326-CPB1-EL-xxx和1326-CPC1-EL-xxx电缆的连接器表面上拆下viton密封,为机柜壁提供间隙。机柜壁的连接应为IP65。6.将隔板连接器穿过墙壁,如图所示:!注意:为避免电击危险,在安装或拆除电缆之前,应切断电机控制器和电机的电源。否则可能导致人身伤害。AB 4.623 mm(0.182 in)机柜壁的最大宽度18出版物1326A-2.11-1998年5月双端隔板连接器1326-xxx-D-xxx和1326-xxx EE xxx连接器的一端有公引脚,另一端有母引脚。连接隔板和双端电缆的指南连接隔板和标准电缆的指南是:•标准连接器只能连接到隔板连接器或460V-1326Ax电机。•隔板连接器只能连接到标准连接器。•将隔板连接到标准连接器时,一个连接器必须具有公引脚,另一个必须具有母引脚。•尽管使用L选项指定的电缆可以连接到没有此选项的电缆或电机,但最终的连接将不具有L选项。•电缆线路的长度不能超过90米。安装直角连接器电缆直角连接器用键固定,以确保方向正确。与电机轴相关的直角连接器连接的1326电缆的方向如下所示:AB AB ALLEN-BRADLEY标准隔板1326 xxx RA xxx和1326 xxx RAL xxx电缆朝向电机轴出口19出版物1326A-2.11-1998年5月1326 xxx RB xxx和1328 xxx RBL xxx电缆远离电机轴出口出版物1326A-1.11-1998月PN#191371 1998罗克韦尔国际。保留所有权利。美国印刷

    The graphic below shows the side view of the bulkhead connector attached by screws and protruding though the flange and a conductive wall (e.g., metal cabinet). The front view shows the pins of the attached bulkhead connector protruding through the wall. AB Outline of the mating Conductive (metal) wall connector Overmold, black pvc B ED C 18-1 I A G F J H Front view Side view 17 Publication 1326A-2.11 - May 1998 Bulkhead Installation Through a Cabinet Wall To prepare a cabinet wall for mounting the bulkhead connector: 1. Locate the area of the cabinet wall where you will mount the bulkhead connector. 2. Mark the places where the four mounting holes and the center connector opening will be located. 3. Drill the four mounting holes and the large center opening. 4. Scrape any paint from the inside surface of the cabinet wall where the bulkhead flange of the 1326-CPB1-E-xxx, 1326-CPB1T-E-xxx, 1326-CPC1- E-xxx, or 1326-CPC1T-E-xxx cables will make contact. Note: All series B cable connectors are treated with a black, highly-conductive, cobalt coating. Do not scrape this coating. Important: A metal-to-metal connection is required to meet CE Compliance standards. 5. Remove the viton seal from the face of the connector for 1326-CCU-EL-xxx, 1326-CPB1-EL-xxx, and 1326-CPC1-EL-xxx cables to provide clearance for the cabinet wall. The connection at the cabinet wall will be IP65. 6. Attach the bulkhead connector through the wall, as shown: ! ATTENTION: To avoid a shock hazard, remove power to the motor controller and motor before installing or removing cables. Failure to do this can cause personal injury. AB 4.623 mm (0.182 in) Maximum width of cabinet wall 18 Publication 1326A-2.11 - May 1998 Double-Ended Bulkhead Connectors The 1326-xxx-D-xxx and the 1326-xxx-EE-xxx connectors have male pins on one end and female pins on the other end. Guidelines for Connecting Bulkhead and Double-Ended Cables The guidelines for connecting bulkhead and standard cables are: • A standard connector can only connect to a bulkhead connector or a 460V-1326Ax motor. • A bulkhead connector can only connect to a standard connector. • When connecting a bulkhead to a standard connector, one connector must have male pins and the other must have female pins. • Though cables designated with the L option can be connected to cables or motors without this option, the resulting connection will not have the L option. • The length of a cable run cannot exceed 90 meters. Installing Right-Angle Connector Cables Right-angle connectors are keyed for correct orientation. The orientation of the 1326 cables attached with right-angle connectors in relation to the motor shaft is shown below: AB AB ALLEN-BRADLEY Standard Bulkhead 1326-xxx-RA-xxx and 1326-xxx-RAL-xxx cables exit towards the motor shaft 19 Publication 1326A-2.11 - May 1998 1326-xxx-RB-xxx and 1326-xxx-RBL-xxx cables exit away from the motor shaft Publication 1326A-2.11 - May 1998 PN# 191371  1998 Rockwell International. All Rights Reserved. Printed in USA

    9.jpg

    20.jpg

    23.jpg



    品牌:ABB

    型号: PFTL101A-2.0 3BSE004172R1 

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号