0041-5065系统控制模块
最大宽度4.623 mm(0.182 in)8出版物1326A-2.11-1998年5月线性弯曲定义为一个方向的弯曲。额定弯曲电缆不适用于双向弯曲的扭转弯曲。不得在扭转应用中使用电力轨道(线性挠性)电缆。用于换向的标准Allen-Bradley电缆-1326-CU-xxx和用于电源的1326-CPB1-xxx或1326-CPC1-xxx为托盘额定(固定)电缆,只能用于一次性挠性应用。•在发生动态线性弯曲的应用中,需要电力轨道布线。在这些应用中使用以下电缆:•1326 CCUT xxx(所有电机的换向)•1326-CPB1T-xxx(1326AS-B3xxx和1326AS-B4xxx电机的电源)•1326-CPC1T-xxx(用于1326AS-B6xxx和1326A S-B8xxx电机的功率)Allen-Bradley高柔电缆具有优异的最小弯曲半径规格,在线性弯曲应用中具有较长的弯曲循环寿命。线性柔性电缆的循环寿命与电缆在电力轨道中的弯曲半径直接相关。有关弯曲半径与循环寿命规格,请参阅下页的图表。9出版物1326A-2.11-1998年5月尺寸信息标准连接器尺寸以下章节提供了各种1326电缆的尺寸、柔性电缆规格和互连信息。图6电机电源和反馈电缆尺寸电源换向连接器最大直径。电缆最大直径。BR CH电缆说明CH1 mm(in.)BR2 mm(in.。)连接器最大直径。不带-L选项连接器最大直径。带-L选项电缆最大直径。1326-CPB1-xxx用于1326AS-B3xxx和1326AS-B4xxx的标准电力电缆110.0(4.3)76.2(3.0)43.2(1.70)47(1.85)14.0(0.55)1326-CPB1 T-xxx用于1326AS-MB3xxx和13.26AS-B4xxx110.0(4.3)104.1(4.1)43.2)47(1.80)10.4(0.41)1326-CPR1-xxx用于1326A S-B6xxx和1326A S-B8xxx的标准电源电缆128.0(5.0)76.1(3.0)54.1(2.13)57.2(2.25)16.3(0.64)1326-CPT1-xxx1326ASB6xxx和1326AS-B8xxx 128.0(5.0)160.2(6.3)54.1(2.13)57.2(2.25)16.0(0.63)1326 CCU xxx电动机旋转变压器用标准换向反馈电缆110.0(4.3)50.8(2.0)36.6(1.44)40.4(1.59)11.0(0.43)1328 CCUT xxx电动机旋转电机用柔性额定换向反馈电缆110.0(4.3)101.6(4.0)36.6,1326 CECU RBx xxx高分辨率反馈,直角(轴出口和后出口)可在5、15、30、60和90m内提供。87.4(3.44)115(4.5)36.6(1.44)40.4(1.59)11.5(0.45)1326 CECUT RAx xxx,1326 CECUTRBx xxx高弹性、高分辨率反馈、直角(轴出口和后出口)有5、15、30、60和90米的选择。87.4 (3.44) 120 (4.7) 36.6 (1.44)
Maximum width 4.623 mm (0.182 in) 8 Publication 1326A-2.11 - May 1998 Linear-flex is defined as flex in one direction. The flex-rated cable is not rated for twist-flex, which is flex in two directions. Power track (linear-flex) cabling must not be used in twist applications. Standard Allen-Bradley cables—1326-CCU-xxx for commutation and 1326-CPB1-xxx or 1326-CPC1-xxx for power—are tray-rated (stationary) and should only be used for one-time flex applications. • Power track cabling is required for applications where dynamic linear flexing occurs. Use the following cables for these applications: • 1326-CCUT-xxx (commutation for all motors) • 1326-CPB1T-xxx (power for 1326AS-B3xxx and 1326AS-B4xxx motors) • 1326-CPC1T-xxx (power for 1326AS-B6xxx and 1326AS-B8xxx motors) Allen-Bradley high-flex cables have excellent minimum bend radius specifications and a long flex cycle life in linear flex applications. The cycle life of linear-flex cable is directly related to the cable’s bend radius in the power track. Refer to the graphs on the following page for Bend Radius vs. Cycle Life specifications. 9 Publication 1326A-2.11 - May 1998 Dimensional Information Standard Connector Dimensions The section below provides dimensions, flex-cable specifications, and interconnect information for the various 1326 cables. Figure 6 Motor Power & Feedback Cable Dimensions Power Commutation Connector Max. Dia. Cable Max. Dia. BR CH Cable Description CH1 mm (in.) BR2 mm (in.) Connector Max. Dia. without -L option Connector Max. Dia. with -L option Cable Max. Dia. 1326-CPB1-xxx Standard power cable for 1326AS-B3xxx and 1326AS-B4xxx 110.0 (4.3) 76.2 (3.0) 43.2 (1.70) 47 (1.85) 14.0 (0.55) 1326-CPB1T-xxx Flex-rated cable for 1326AS-B3xxx and 1326AS-B4xxx 110.0 (4.3) 104.1 (4.1) 43.2 (1.70) 47 (1.85) 10.4 (0.41) 1326-CPC1-xxx Standard power cable for 1326AS-B6xxx and 1326AS-B8xxx 128.0 (5.0) 76.2 (3.0) 54.1 (2.13) 57.2 (2.25) 16.3 (0.64) 1326-CPC1T-xxx Flex-rated power cable for 1326ASB6xxx and 1326AS-B8xxx 128.0 (5.0) 160.2 (6.3) 54.1 (2.13) 57.2 (2.25) 16.0 (0.63) 1326-CCU-xxx Standard commutation feedback cable for motor resolver 110.0 (4.3) 50.8 (2.0) 36.6 (1.44) 40.4 (1.59) 11.0 (0.43) 1326-CCUT-xxx Flex-rated commutation feedback cable for motor resolver 110.0 (4.3) 101.6 (4.0) 36.6 (1.44) 40.4 (1.59) 10.1 (0.40) 1326-CECU-RAx-xxx, 1326-CECU-RBx-xxx High-resolution feedback, right-angle (shaft exit and rear exit) is available in 5, 15, 30, 60, and 90m. 87.4 (3.44) 115 (4.5) 36.6 (1.44) 40.4 (1.59) 11.5 (0.45) 1326-CECUT-RAx-xxx, 1326-CECUT-RBx-xxx High-flex, high-resolution feedback, right-angle (shaft exit and rear exit) is available in 5, 15, 30, 60, and 90m. 87.4 (3.44) 120 (4.7) 36.6 (1.44)