您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

PFTL301E 1.0KN 3BSE019050R1000工控模块系统备件

PFTL301E 1.0KN 3BSE019050R1000工控模块系统备件

PFTL301E 1.0KN 3BSE019050R1000工控模块系统备件 格安全输出,编号440F-C28011 440F-C2801 2 440F-C2803 440F-C28021 440F-C2 8023 440F-C2802 4 440F-C2805 440F-C2 802 6 2 N/O独立无电压2 N/O无电压2 N/O独立无电压6 N/O无电压6 N/O独立电压2 N/O独立无压...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

PFTL301E 1.0KN 3BSE019050R1000工控模块系统备件

    PFTL301E 1.0KN 3BSE019050R1000工控模块系统备件

     格安全输出,编号440F-C28011 440F-C2801 2 440F-C2803 440F-C28021 440F-C2 8023 440F-C2802 4 440F-C2805 440F-C2 802 6 2 N/O独立无电压2 N/O无电压2 N/O独立无电压6 N/O无电压6 N/O独立电压2 N/O独立无压2 N/O独立无电压辅助输出,编号440F-C28011 440F-C2801 2 440F-C2803 440F-C28021 440F-C2 8023 440F-C2802 4 440F-C2805 440F-C2 802 6 1 N/C独立无电压0 1 N/C无电压1 N/O独立无电压1 N/O独立无无电压0 0 1 N/C独立无压输出额定值最大值440F-C2 8011 440F-C28012 440F-C2 801 3 440F-C2 803 440F-C28021 440 F-C28023 440F-C2802 4 440 F-C2802 5 440F-C28046最小值(所有型号):4 A/250V AC/1000V A、3 A/30V DC/90 W、4 A/250V AC/1000V B、3 A/30 V DC/90 V、4 A/250 V AC/1000A、3 A/30V DC/90W、4 A/250V AC/1000 V A、5 A/30V DC/90 W、4 A/250V AC/1000V A、3 A/30V DC/99 W、2 A/30V DC/60 W、2 A/30 V DC/600 W、3 A/250 V AC/500V A、10 mA,10V工作温度-10…45°C(+14…113°F)额定绝缘电压250V,(外部接线必须与额定绝缘电压兼容)污染等级II冲击耐受电压2500V AC湿度90%RH外壳保护钢,IP65扭矩设置-主螺钉1,3Nm振动0.15 mm,10…55Hz冲击10 g,11 ms,半正弦标准EN1760-1,EN954-1,ISO13849-1,IEC/EN6004-1,ANSI RIA R15.06,ANSI B11.19,AS4024.5类别类别。符合EN954-1的1个装置。控制单元提供的3个系统工作电压24V DC+10%-20%。在直径为80 mm(3.125 in.)的圆盘上,有保证检测的人员的最小重量为30 Kg(66 lbs)。最大检测区域100 m2(1076 sq ft)单个垫的最大数量8连接线的最大总长度200 m(656 ft)重量10.9 kg/m2(2.2 lbs/ft2)环境保护IP67(NEMA 6P)机械寿命1000000次湿度0…100%RH颜色黄色或黑色工作温度范围-10…55°C(-14…131°F)存储温度范围-40…+70°C(-40…158°F)厚度16 mm(0.63 in.)尺寸在标称尺寸440F MatGuard上增加6 mm™ Mat Manager用户手册第4节-规范10罗克韦尔自动化出版物95302194/EO:0240发行号:8)4.3传感器垫尺寸传感垫的安装需要将垫固定到位的方法。这是使用周界修剪完成的。当需要多个垫子覆盖一个区域时,需要在各个垫子之间进行主动联合修剪。在计算总覆盖面积时,必须考虑这些修剪(周长和主动合并)。图6显示了计算总面积时需要添加到标称垫尺寸的额外距离。例如,一个系统具有四个1500 mm x 1000 mm的垫子,带有440F-T3*10周边装饰和主动式

    sect4.2 Sensor Mat Specifications Safety Outputs, Number 440F-C28011 440F-C28012 440F-C28013 440F-C28021 440F-C28023 440F-C28024 440F-C28025 440F-C28026 2 N/O independent voltage free 2 N/O independent voltage free 2 N/O independent voltage free 6 N/O independent voltage free 6 N/O independent voltage free 2 N/O independent voltage free 2 N/O independent voltage free 2 N/O independent voltage free Auxiliary Outputs, Number 440F-C28011 440F-C28012 440F-C28013 440F-C28021 440F-C28023 440F-C28024 440F-C28025 440F-C28026 1 N/C independent voltage free 0 1 N/C independent voltage free 1 N/O independent voltage free 1 N/O independent voltage free 0 0 1 N/C independent voltage free Output Ratings Maximum 440F-C28011 440F-C28012 440F-C28013 440F-C28021 440F-C28023 440F-C28024 440F-C28025 440F-C28026 Minimum (all models): 4 A/250V AC/1000V A, 3 A/30V DC/90 W 4 A/250V AC/1000V A, 3 A/30V DC/90 W 4 A/250V AC/1000V A, 3 A/30V DC/90 W 4 A/250V AC/1000V A, 3 A/30V DC/90 W 4 A/250V AC/1000V A, 3 A/30V DC/90 W 2 A/30V DC/60 W 2 A/30V DC/60 W 4 A/250V AC/500V A, 3 A/30V DC/90 W 10 mA at 10V Operating Temperature -10…45°C (+14…113°F) Rated insulation voltage 250V, (external wiring must be compatible with the rated insulation voltage) Contamination Level II Impulse Withstand Voltage 2500V AC Humidity 90% RH Enclosure Protection Steel, IP65 Torque Settings - main screw 1, 3Nm Vibration 0.15 mm, 10…55Hz Shock 10 g, 11 ms, half-sine Standards EN1760-1, EN954-1, ISO13849-1, IEC/EN60204-1, ANSI RIA R15.06, ANSI B11.19, AS4024.5 Category Cat. 1 device per EN954-1. Suitable for Cat. 3 systems Operating Voltage 24V DC +10% - 20% provided by the control unit. Minimum weight of person with assured detection 30 Kg (66 lbs) on an 80 mm (3.125 in.) diameter circular disk. Maximum detection zone 100 m2 (1076 sq ft) Maximum number of individual mats 8 Maximum total length of connection wires 200 m (656 ft) Weight 10.9 kg/m2 (2.2 lbs/ft2 ) Environmental protection IP67 (NEMA 6P) Mechanical life 1,000,000 operations Humidity 0…100% RH Color Yellow or Black Operating temperature range -10…55°C (-14…131°F) Storage temperature range -40…+70°C (-40…158°F) Thickness 16 mm (0.63 in.) Size Add 6 mm to nominal size 440F MatGuard™ Mat Manager User Manual Section 4 - Specifications 10 Rockwell Automation Publication 95302194/EO:0240 Issue No: 8) 4.3 Sensor Mat Dimensions Installation of the sensing mat requires a method of retaining the mat in place. This is accomplished using the perimeter trim. When multiple mats are needed to cover an area, active uniting trim is needed between the individual mats. Each of these trims (perimiter and active uniting) must be taken into account when calculating the total area covered. Figure 6 shows the additional distances that need to be added to the nominal mat sizes when calculating the total area. For example, a system with four 1500 mm x 1000 mm mats with 440F-T3*10 perimeter trim and active

    8.jpg

    微信图片_20220816092435.png



    品牌:ABB

    型号: PFTL301E 1.0KN 3BSE019050R1000 

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号