PM150V08 3BSE003641R1输入输出模块
双转换电气输入标称输入电压208V/120V,220V/127V+10,-15%480V/277V,600V(480+600,带变压器)400V型号也可用工作频率50/60 Hz(45至65 Hz)输入功率因数0.99典型输入电流失真<5%THD电气输出标称输出电压208/120,220/120 Vac 480/227,带输出变压器输出电压调节±1%静态;±4%动态,1 ms响应时间内100%阶跃负载恢复效率91%,典型散热(BTU/hr)20 kVA型号6762@208V,220V输入10450@480V和600V(带输入隔离变压器)30 kVA型号:9220@208V和220V输入13831@480V或600V(带输出隔离变压器)电池类型9 Ah,密封,铅酸,免维护电池运行时间参见电池备份时间表电池更换现场可更换充电器默认为8A并联冗余是,使用Powerware热同步技术和容量通用诊断启动时的全系统自检UPS旁路过载或UPS故障时自动并联冗余是的,使用Powerware热同步技术实现冗余和容量尺寸和重量请参阅型号选择表过载150%5秒/125%1分钟(在线),110%10分钟通信LCD显示屏带有蓝色背光LED的图形LCD(4)用于通知和警报的LED声音警报是通信端口(1)RS-232,(1)继电器触点,(2)环境输入通信插槽(2)X插槽通信托架电源管理软件捆绑软件套件CD环境工作温度50–104ºF(10–40ºC),45ºC,降额7.5%;最佳电池性能:77ºF(25ºC)存储温度32–77ºF;建议的电池存储:59–77ºF(15–25ºC)相对湿度0–95%,1米处的非冷凝声音<58 dBA,取决于负载海拔高度<3000m认证安全认证IEC 62040-1-1、IEC 60950、EN 62040-1-1,UL 1778、NOM-0190SCP8-1993 EMC符合EN 50091-2 A级质量ISO 9001:2000和ISO 14001:1996标记UL、cUL、NOM-NOME 1。由于产品的不断改进,程序规范可能会发生更改,恕不另行通知。LCD控制面板电源模块静态开关REPO端子DB-9服务端口20/30 kVA UPS维护旁路输入断路器模块化电池区电池断路器X插槽通信间隔(2)www.eaton。com/powerquality1.800.356.5794 13带机械旁路开关的配电模块(10和15 kVA型号)NEMA输出插座1个插座输入“插座代码”数量断路器电压
Double conversion Electrical input Nominal input voltage 208V/120V, 220V/127V +10, -15% 480V/277V, 600V (480+600 with transformer) 400V models also available Operating frequency 50/60 Hz (45 to 65 Hz) Input power factor 0.99 typical Input current distortion <5% THD Electrical output Nominal output voltage 208/120, 220/120 Vac 480/227 with output transformer Output voltage regulation ±1% static; ±4% dynamic with 100% step load recovery within 1 ms response time Efficiency 91%, typical Heat dissipation (BTU/hr) 20 kVA models 6,762 @ 208V and 220V input 10,450 @ 480V and 600V (with input isolation transformer) 30 kVA models: 9,220 @ 208V and 220V input 13,831 @ 480V and 600V (with input isolation transformer) Battery Battery type 9 Ah, sealed, lead-acid, maintenance-free Battery runtime See battery backup time chart Battery replacement Field-replaceable Charger Default is 8A Parallel for redundancy Yes, using Powerware Hot Sync technology and capacity General Diagnostics Full system self-test at startup UPS bypass Automatic on overload or UPS failure Parallel for redundancy Yes, using Powerware Hot Sync technology for redundancy and capacity Dimensions and weights See model selection table Overload 150% for 5 sec / 125% for 1 min (online), 110% for 10 min Communications LCD display Graphical LCD with blue backlight LEDs (4) LEDs for notice and alarm Audible alarms Yes Communication ports (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input Communication slot (2) X-Slot communication bays Power management software Bundled Software Suite CD Environmental Operating temperature 50–104ºF (10–40ºC), 45ºC with 7.5% derating; Optimal battery performance: 77ºF (25ºC) Storage temperature 32–77ºF (0–25ºC); Recommended battery storage: 59–77ºF (15–25ºC) Relative humidity 0–95%, non-condensing Audible noise < 58 dBA at 1 meter depending on load Altitude <3000m Certifications Safety certifications IEC 62040-1-1, IEC 60950, EN 62040-1-1, UL 1778, NOM-0190SCP8-1993 EMC compliance EN 50091-2 Class A Quality ISO 9001: 2000 and ISO 14001:1996 Markings UL, cUL, NOM-NYCE 1. Due to continuous product improvements, program specifications are subject to change without notice. LCD control panel Power modules Static switch REPO terminal DB-9 service port 20/30 kVA UPS Maintenance bypass Input breaker Modular battery area Battery breaker X-Slot communication bay (2) www.eaton.com/powerquality 1.800.356.5794 13 Power Distribution Module with Mechanical Bypass Switch (10 and 15 kVA Models) NEMA Output Receptacle(s)1 Receptacle Enter “Receptacle Code” Quantity Breaker Voltage