PM253V01 492943601模块备件
2.除非使用输入隔离变压器,否则所有配置都需要输入中性点。对于并联系统,将第五个配置为顺序(CTO)数字更改为2,并包括并联接线柜。3.对于两个高配置,增加47 lb,对于三个高配置增加50 lb,以确定装运重量。4.220V机组为Y形连接220/127V输入和220/127V输出,三相,四线加接地。1.50/60 Hz自动感应。2.除非使用输入隔离变压器,否则所有配置都需要输入中性点。对于并联系统,将第五个CTO数字更改为2,并包括并联接线柜。3.所有型号均包括内置电池。4.增加50磅以确定装运重量。5.包含车载维护旁路。6.带隔离变压器。7.220V装置为Y形连接220/127V输入和220/127V输出,三相,四线加接地。网址:www.eaton。com/powerquality1.800.5356.5794 11 10-15 kVA备份时间UPS(1)(2)(3)(4)UPS(2)+内部EBM EBM EBM-EBM+内部EBM-EBM-EBM VA Watt 32电池33 127 238 359-77 238 423-3000 2700 38 148 277 418-90 277-2500 2250 46 176 329-107 329-注意:备份时间是近似的,可能因设备、配置、电池寿命、温度、,等20-30 kVA备用时间UPS内部内部+内部电池+电池组VA瓦特1电池EBC-36+(1)EBC-72电池备用时间(分钟)10和15 kVA1额定功率(kVA/瓦特)技术规范0.9功率因数下10 kVA/9 kW和15 kVA/13.5 kW拓扑双转换电气输入标称输入电压208V/120V或220V/127V三相400V型号也可提供输入电压范围-15%,在100%负载下+10%,不消耗电池工作频率50/60 Hz(45至65 Hz)输入功率因数>0.99典型值,>0.96变频器输入电流失真5%THD电气输出标称输出电压208/120,220/127 Vac输出电压调节±1%静态;100%电阻负载变化时±5%动态,
2. An input neutral is required for all configurations unless the input isolation transformer is used. For parallel systems, change the fifth configure-to-order (CTO) digit to a 2 and include parallel tie cabinet. 3. Add 47 lb. for two-high configurations or 50 lb. for three-high configurations to determine shipping weight. 4. 220V units are wye connected 220/127V input and 220/127V output, three-phase, four-wire plus ground. 1. 50/60 Hz auto-sensing. 2. An input neutral is required for all configurations unless the input isolation transformer is used. For parallel systems, change the fifth CTO digit to a 2 and include parallel tie cabinet. 3. All models include internal batteries. 4. Add 50 lb. to determine shipping weight. 5. Contains on-board maintenance bypass. 6. With isolation transformer. 7. 220V units are wye connected 220/127V input and 220/127V output, three-phase, four-wire plus ground. www.eaton.com/powerquality 1.800.356.5794 11 10-15 kVA backup times UPS (1) (2) (3) (4) UPS (1) (2) (3) + Internal EBM EBM EBM EBM + Internal EBM EBM EBM VA Watt 32 Battery 33 127 238 359 - 77 238 423 - 3000 2700 38 148 277 418 - 90 277 - - 2500 2250 46 176 329 - - 107 329 - - Note: Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc. 20-30 kVA backup times UPS Internal Internal Internal + Internal Battery + Battery Battery VA Watt 1 Battery EBC - 36 + (1) EBC - 72 Battery backup times (in minutes) Technical Specifications for 10 and 15 kVA1 Power Ratings (kVA/Watts) 10 kVA/9 kW and 15 kVA/13.5 kW at 0.9 power factor Topology Double conversion Electrical input Nominal input voltage 208V/120V or 220V/127V three-phase 400V models also available Input voltage range -15%, +10% from nominal at 100% load without depleting battery Operating frequency 50/60 Hz (45 to 65 Hz) Input power factor >0.99 typical, >0.96 frequency converter Input current distortion 5% THD Electrical output Nominal output voltage 208/120, 220/127 Vac Output voltage regulation ±1% static; ±5% dynamic at 100% resistive load change,