PP846A 3BSE042238R1工控模块备件
页码类别。单功能安全继电器MSR131RTP 3 N.O.2 N.C.,2 PNP固态可拆卸(螺钉)自动/手动或监控手动24V AC/DC说明440R-C23139 MSR30RT 2常开固态1常开固态可拆卸自动/手动或监控手动24V DC描述440R-N23198专用安全继电器MSR23M 2 N.O.1 N.C.固定自动/手动监控手动24V AC/DC描述440R-P23073 Mat控制器2 N.O.2 N.C.固定手动/手动监控24V AC/DC或115/230V AC描述440F-C4000S Mat Manager 2 N.O/手动监控手动24V DC说明440F-C28011模块化安全继电器MSR210P底座(2 N.C.)2 N.O.1 N.C.和2 PNP固态和2 PNN固态可拆卸自动/手动或监控来自基本单元的24V DC说明440R-H23176 MSR220P输入模块(全部)-可拆卸-24V DC说明440 R-H23178 MSR320P输入模件(全部)-2 PNP固态可拆卸-来自基础单元的24V直流说明440R-W23218注:有关其他安全继电器连接,请参阅本目录的逻辑部分。有关其他安全I/O连接,请参阅本目录的安全I/O部分。有关应用程序和接线图,请参阅本目录的应用程序部分。连接系统连接4针5针线组889D‐F4AC‐⋆ 889D‐F5AC‐⋆ 跳线889D‐F4ACDM‐‡889D‐F5ACDM‐†配电箱898D‐4§LT‐DM4 NA短接插头898D-41LU-DM NA T端口898D-43LY-D4 NA⋆ 对于标准电缆长度,将符号替换为2(2 m)、5(5 m)或10(10 m)。‡对于标准电缆长度,将符号替换为1(1 m)、2(2 m)、3(3 m)、5(5 m)或10(10 m)。§端口数用4或8替换符号。典型接线图安全垫、监控手动重置、双通道输出、监控输出安全垫、自动重置、无输出监控安全垫、双通道监控输出、手动重置、输出监控四个单独监控的安全垫、手动监控重置、双输出、,输出监控注意:所示二极管可以是带有内置二极管(1492-JD3DF或1492-JD3D R)的接线板。
Page No. Cat. No. Single-Function Safety Relays MSR131RTP 3 N.O. 2 N.C., 2 PNP solid state Removable (Screw) Auto./Manual or Monitored Manual 24V AC/DC Description 440R-C23139 MSR30RT 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC Description 440R-N23198 Specialty Safety Relays MSR23M 2 N.O. 1 N.C. Fixed Automatic/Manual Monitored Manual 24V AC/DC Description 440R-P23073 Mat Controller 2 N.O. 1 N.C. Fixed Automatic/Manual Monitored Manual 24V AC/DC or 115/230V AC Description 440F-C4000S Mat Manager 2 N.O. 1 N.C. Fixed Auto./Manual Monitored Manual 24V DC Description 440F-C28011 Modular Safety Relays MSR210P Base (2 N.C.) 2 N.O. 1 N.C. and 2 PNP Solid State and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit Description 440R-H23176 MSR220P Input Module (all) — — Removable — 24V DC Description 440R-H23178 MSR320P Input Module (all) — 2 PNP Solid State Removable — 24V DC from the base unit Description 440R-W23218 Note: For additional Safety Relays connectivity, see the Logic section of this catalog. For additional Safety I/O connectivity, see the Safety I/O section of this catalog. For Application and wiring diagrams, see the Applications section of this catalog. Connection Systems Connection 4-Pin 5-Pin Cordset 889D‐F4AC‐⋆ 889D‐F5AC‐⋆ Patchcord 889D‐F4ACDM‐‡ 889D‐F5ACDM‐‡ Distribution Box 898D‐4§ LT‐DM4 NA Shorting Plug 898D-41LU-DM NA T-Port 898D-43LY-D4 NA ⋆ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. ‡ Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. § Replace symbol with 4 or 8 for number of ports. Typical Wiring Diagrams Safety Mat, Monitored Manual Reset, Dual Channel Output, Monitored Output Safety Mat, Automatic Reset, No Output Monitoring Safety Mat, Dual Channel Output Monitored, Manual Reset, Output Monitoring Four Individually Monitored Safety Mats, Monitored Manual Reset, Dual Output, Output Monitoring Note: The diodes shown can be terminal blocks with built-in diodes (1492-JD3DF or 1492-JD3DR).