PP886H 3BSE069297R1工控模块系统备件
图3 DIN导轨安装电气连接安装通信适配器并安装通信套件后,进行所有必要的电气连接。参见图4及其显示连接器及其连接程序的相关表格。图4连接到通信套件96.3 mm(3.79 in.)85.3 mm(3.36 in.)Ö4 mm(0.16 in.)端口MOD NET A NET B!注意:存在设备损坏、受伤或死亡的风险。如果无法验证参数设置和开关设置是否与应用程序兼容,则可能会发生无法预测的操作。在给驱动器通电之前,请验证设置是否与应用程序兼容。项目描述连接程序➊ 网络的网络连接器连接。将网络电缆插头插入通信适配器上的配合连接器。+/-串行DSI DC ADP+DC-➊ ➎ ➍➌ ➋ 3配置通信适配器安装并连接通信套件后,配置通信适配器。有关完整的详细信息,请参阅《通信适配器用户手册》。外部通信套件规范通信电气机械环境法规遵从性注:这是符合IEC 61800-3的C2类产品。在家庭环境中,该产品可能会造成无线电干扰,在这种情况下,可能需要采取补充缓解措施。➋ 24V DC电源接线板(1)连接24V DC(+15%/-25%)电源。将直流电源的“+”和“-”线连接到2针线性插头(随通信套件提供),以匹配各自的极性。然后将2针线性插头插入匹配的直流电源接线板。注:当使用附件20-XCOMM-AC-PS1电源适配器为通信套件供电时,该接线板可用于将24V DC菊花链连接到其他套件(图5)。➌ 交流至直流适配器连接器(1)(2)不使用直流电源时,用于交流至直流转换器的连接,如Allen-Bradley 20-XCOMM-AC-PS1。将适配器插入匹配的DC ADP连接器。➍ DSI的DSI连接器连接。
Figure 3 DIN Rail Mounting Electrical Connections After the communication adapter is installed and the Comms Kit is mounted, make all required electrical connections. See Figure 4 and its related table showing the connectors and their connection procedures. Figure 4 Connecting to the Comms Kit 96.3 mm (3.79 in.) 85.3 mm (3.36 in.) Ø 4 mm (0.16 in.) PORT MOD NET A NET B ! ATTENTION: Risk of equipment damage, injury or death exists. Unpredictable operation may occur if you fail to verify that parameter settings and switch settings are compatible with your application. Verify that settings are compatible with your application before applying power to the drive. Item Description Connection Procedure ➊ Network Connector Connection for the network. Insert the network cable plug into the mating connector on the communications adapter. + - Serial DSI DC ADP + DC - ➊ ➎ ➍➌ ➋ 3 Configuring the Communications Adapter After mounting and connecting the Comms Kit, configure the communication adapter. Refer to the Communication Adapter User Manual for complete details. External Comms Kit Specifications Communications Electrical Mechanical Environmental Regulatory Compliance NOTE: This is a product of category C2 according to IEC 61800-3. In a domestic environment this product may cause radio interference in which case supplementary mitigation measures may be required. ➋ 24V DC Power Terminal Block (1) Connection for 24V DC (+15% / -25%) power source. Connect the “ + ” and “ - ” wires of the DC power source to the 2-pin linear plug (provided with Comms Kit), matching the respective polarity. Then insert the 2-pin linear plug into the mating DC power terminal block. NOTE: When powering the Comms Kit with the accessory 20-XCOMM-AC-PS1 power adapter, this terminal block can be used to daisy-chain 24V DC to other kits (Figure 5). ➌ AC-to-DC Adapter Connector (1)(2) Connection for AC-to-DC adapter, such as Allen-Bradley 20-XCOMM-AC-PS1, when not using a DC power source. Plug the adapter into the mating DC ADP connector. ➍ DSI Connector Connection for DSI.