您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

PROSOFT RLX2-IHNF-A机器人模块卡件

PROSOFT RLX2-IHNF-A机器人模块卡件

PROSOFT RLX2-IHNF-A机器人模块卡件信号返回屏障电阻和电源屏障电阻必须满足以下两个公式。用户必须提供Base Type Voltage Supply Cat的值。编号端子13…29.5V DC 42DTB-5500工作模式输出特性类别。No.Reflex NPN(电流吸收器)和PNP(电流源)42DRU-5500偏振反射42DRU-5700接近42DRP-5500光纤广角固定焦点4...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

PROSOFT RLX2-IHNF-A机器人模块卡件

    PROSOFT RLX2-IHNF-A机器人模块卡件

    信号返回屏障电阻和电源屏障电阻必须满足以下两个公式。用户必须提供Base Type Voltage Supply Cat的值。编号端子13…29.5V DC 42DTB-5500工作模式输出特性类别。No.Reflex NPN(电流吸收器)和PNP(电流源)42DRU-5500偏振反射42DRU-5700接近42DRP-5500光纤广角固定焦点42DRA-5500重要信息NPN和输出配置不允许用于I类1区A或B组的危险场所。罗克韦尔自动化出版物42DR-IN001B-EN-P-2016年5月5本质安全传感器-负载电压降Vload和负载电流Iload。请注意,在此配置中,Iload最大值为10 mA。Rbps=Vs-13 Rbps+Rbrs=Vs-(o.4+Vbrs+Vload)Iload+0.026 Iload+0.026其中:Rbps=最大电源屏障电阻Rbrs=最大信号返回屏障电阻Vs=电源Vload=负载电压降13=最小。控制电源电压(13V)0.026=电源电流(13V时最大26mA)Iload=负载电流(最大10mA)Vbrs=信号返回屏障电压降0.4=输出开关电压降(0.4V)42DR系列5500型相邻安装单元的安装可在两个不同频率范围中的一个频率范围内运行,允许光头彼此靠近安装而不产生干扰信号。开放频率范围内的单位用点(S)标记。其他频率范围内的单位没有点。因此,当两个42DR系列5500型控制器紧密安装在一起和/或彼此面对时,选择Photoheads,使其中一个标有点(•),另一个没有点。对准42DR型LED控制装置的对准可通过使用反射操作在反射器处目视瞄准控制装置或使用接近物在物体处目视瞄准,直到开关处于“LT”位置时顶部可见LED指示灯亮起或开关处于“DK”位置时熄灭。

    The signal return barrier resistance and the power supply barrier resistance must satisfy the following two formulas. The user must provide values for Base Type Voltage Supply Cat. No. Terminal 13…29.5V DC 42DTB-5500 Operating Mode Output Characteristics Cat. No. Reflex NPN (Current Sink) and PNP (Current Source) 42DRU- 5500 Polarized Reflex 42DRU- 5700 Proximity 42DRP- 5500 Fiber Optic Wide Angle Fixed Focus 42DRA- 5500 IMPORTANT The NPN and output configuration is not approved for use in hazardous locations classified as Class I, Division 1, Groups A or B. Rockwell Automation Publication 42DR-IN001B-EN-P - May 2016 5 Intrinsically Safe Sensor the load voltage drop, Vload, and the load current, Iload. Please note that Iload is 10 mA max in this configuration. Rbps = Vs - 13 Rbps + Rbrs = Vs - (o.4 + Vbrs + Vload) Iload + 0.026 Iload + 0.026 where: Rbps = Max. Power Supply Barrier Resistance Rbrs = Max. Signal Return Barrier Resistance Vs = Voltage Supply Vload = Load Voltage Drop 13 = Min. Voltage Supply to Control (13V) 0.026 = Supply Current (26mA max. at 13V) Iload = Load Current (10mA max.) Vbrs = Signal Return Barrier Voltage Drop 0.4 = Output Switch Voltage Drop (0.4V) Installation of Adjacently Mounted Units Type 42DR Series 5500 Photoheads are supplied to operate at one of two different frequency ranges, permitting Photoheads to be mounted close to each other without generating interfering signals. Units in open frequency range are marked with a dot (S). Units in the other frequency range have no dot. Accordingly, when two Type 42DR Series 5500 controls are mounted close together and/or face each other, select Photoheads so that one is marked with a dot (•) and the other has no dot. Alignment Alignment of the Type 42DR LED control can be accomplished by visually sighting the control at the reflector using reflex operation or at the object using proximity until the visible LED indicator on the top lights with switch in the “LT” position or goes out when the switch is in “DK” position. 

    11.jpg

    微信图片_20220816092435.png



    品牌:ABB

    型号:PROSOFT RLX2-IHNF-A 

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号