GE IS220PAICH1A 336A4940CSP3 工控模块机器人备件
当启用双扫描模式时,使用电位计1可以使检测的最小持续时间更长。此额外的时间延迟可以从0到3.3秒不等。表10-J2引脚列表引脚信号说明备注1 0V DC电源-2+24V DC电源-3接地-4未连接未连接-5输入2未使用-6输入1未使用DIP开关S1(3)=0远程示教DIP开关S2(3)=1 7输出2错误0V DC=错误8输出1灯阵列中断0V DC=中断24V DC=未中断输入2 PNP NPN PNP NPP D7 LED-电源D3 LED输出1 D4LED输出2 D6 LED输入2 D5 LED输入1 RJ45连接器发射器RJ45连接器接收器D2 LED输入1电位计2电位计1可拆卸弹簧加载连接器输入逻辑跳线S1 J2输出1输出2输入1输入2 n.c.接地。24 VDC 0 VDC表11-基本型号DIP开关设置功能DIP开关S1(0:关闭,1:打开,X:不相关)87654321默认设置0 0 0 0 00 0 0 0最大发射器功率(100%)0xxxxx00降低发射器功率(最大值的75%)0xxxxx01降低发射器功率,最大值的60%)0xxxxx10降低发射器功率输出逻辑光操作=24V(PNP L.O.)暗操作=0V(NPN D.O.)0xx0xxxx输出逻辑光运行=0V安装说明教示说明基本控制器提供教示操作期间未评估的空白区域的功能。您可以在阵列的一端或两端配置空白区域(例如,如果阵列对于应用程序来说太长);或者在数组中间有一个空白区域(如果中间的某个区域太被忽略)。要激活示教功能,必须打开DIP开关3(并重启控制器电源)以启用远程示教。启用远程设定后,通过打开离散输入IN 1启动设定过程。When the double-scan mode is enabled, the minimum duration of detection can be made even longer with the use of potentiometer one. This additional time delay can range from 0…3.3 seconds. Table 10 - J2 Pin Listings Pin Signal Description Remarks 1 0V DC Power — 2 +24V DC Power — 3 Ground Ground — 4 Not connected Not connected — 5 In 2 Not used — 6 In 1 Not used DIP switch S1 (3) = 0 Remote teach DIP switch S1 (3) = 1 7 Out 2 Error 0V DC = Error 8 Out 1 Light array interrupted 0V DC = interrupted 24V DC = not interrupted In 2 PNP NPN PNP NPN D7 LED - Power D3 LED Out 1 D4 LED Out 2 D6 LED In 2 D5 LED In 1 RJ45 Connector Emitter RJ45 Connector Receiver D2 LED D1 LED In 1 Pot 2 Pot 1 Removable Spring-Loaded Connector Input Logic Jumpers S1 J2 Out 1 Out 2 In 1 In 2 n. c. Earth. 24 VDC 0 VDC Table 11 - Basic Model DIP Switch Settings Function DIP Switch S1 (0: OFF, 1: ON, X: not relevant) 87654321 Default setting 0 0 0 0 0 0 0 0 Maximum emitter power (100%) 0xxxxx00 Reduce emitter power (75% of max) 0xxxxx01 Reduce emitter power (60% of max) 0xxxxx10 Reduce emitter power (15% of max) 0xxxxx1 1 Enable remote teach 0 x x x x 1 x x Enable double scan filter 0 x x x 1 x x x Output logic Light Operate = 24V (PNP L.O.) Dark Operate = 0V (NPN D.O.) 0xx0xxxx Output logic Light Operate = 0V (NPN L.O.) Dark Operate = 24V (PNP D.O.) 0xx1xxxx Standard beam counting direction 0x0xxxxx Reverse beam counting direction 0x1xxxxx Normal operation 0 x x x x x x x Set default 1 x x x x x x x 6 Rockwell Automation Publication 45MLA-IN002C-EN-P - August 2020 45MLA Controller Installation Instructions Teach Instructions The Basic Controller offers the ability to teach blanked zones that are not evaluated during operation. You can either configure blanked zones at one or both ends of the array (for example if the arrays are too long for the application); OR one blanked zone in the middle of the array (if an area in the middle is too be ignored). To activate the teach capability DIP switch 3 must be turned ON (and controller power cycled) to enable the remote teach. Once the remote teach is enabled, the teach process is initiated by turning the discrete input IN 1 ON.