ABB PPC907BE 3BHE024577R0101 模块控制器
输入2个PNP NPN PNP NPP D7 LED-电源I/O扩展PCB D3 LED输出1个D4 LED输出2个D6 LED输入2个D5 LED输入1个D13 LED D14 LED D12 LED D11 LED D10 LED RJ45连接器发射器RJ45连接器接收器D2 LED D1输入1个电位计2个电位计1个示教按钮可拆卸弹簧加载连接器输入逻辑跳线S1 J2 J14输出1个输出2个输入1个接地。24 VDC 0 VDC表12-J2引脚列表引脚信号说明备注1 0V DC电源-2+24V DC电源-3接地-4未连接未连接-5入2触发并保持DIP开关S1(7)=0后悬传感器DIP开关S2(7)=1 6入1未使用DIP开关S3(7)=0前悬传感器DIP开关S1(8)=1 7出2灯阵列中断(1)(1)或高度过高(特殊功能)0V DC=中断的24V DC=未中断的8输出1悬垂0V DC=悬垂24V DC=无悬垂表13-J14引脚列表引脚信号0V DC+24V DC 1输出3区域Z1中断区域Z1未中断2输出4区域Z2中断区域Z2未中断3输出5区域Z3中断区域Z3未中断4输出6区域Z4中断区域Z4未中断表14-I/O板状态指示器状态指示器描述状态含义D10区域1关闭输出3=关闭(0V DC)绿色输出3=打开(24V DC)D11区域2关闭输出4=关闭(0 V DC)绿色出口4=打开(24 V DC)D12区域3关闭输出5=关断(0 V直流)绿色输出5=开启(24 V直流)D13区域4关闭输出6=关闭(V DC)蓝色输出6=打开(24VDC)D14示教关闭非激活闪烁示教进行中橙色最后一个示教步骤罗克韦尔自动化出版物45MLA-IN002C-EN-P-2020年8月7 45MLA控制器安装说明DIP开关设置S1 DIP开关阵列上的DIP开关1…6配置用于表15中所述的各种应用。
Input 2 PNP NPN PNP NPP D7 LED - power I/O expansion PCB D3 LED output 1 D4 LED output 2 D6 LED input 2 D5 LED input 1 D13 LED D14 LED D12 LED D11 LED D10 LED RJ45 connector transmitter RJ45 connector receiver D2 LED D1 input 1 potentiometer 2 potentiometers 1 teaching button detachable spring loaded connector input logic jumper S1 J2 J14 output 1 output 2 input 1 ground. 24 VDC 0 VDC Table 12-J2 Pin List Pin Signal Description Remarks 1 0V DC power supply - 2+24V DC power supply - 3 Grounding - 4 Not connected Not connected - 5 In 2 Trigger and keep DIP switch S1 (7)=0 Rear suspension sensor DIP switch S2 (7)=1 6 In 1 Not used DIP switch S3 (7)=0 Front suspension sensor DIP switch S1 (8)=1 7 Out 2 Lamp array interrupt (1) (1) or high (special function) 0V DC=Interrupted 24V DC=Uninterrupted 8 Output 1 Suspension 0V DC=Suspension 24V DC=No Suspension Table 13-J14 Pin List Pin Signal 0V DC+24V DC 1 Output 3 Area Z1 Interruption Area Z1 Uninterruption 2 Output 4 Area Z2 Interruption Area Z2 Uninterruption 3 Output 5 Area Z3 Interruption Area Z3 Uninterruption 4 Output 6 Area Z4 Interruption Area Z4 Uninterruption Table 14-I/O Board Status Indicator Status Indicator Description Status Meaning D10 Area 1 Closed Output 3=Closed (0V DC) Green Output 3=Open (24V DC) D11 area 2 closed output 4=closed (0 V DC) green output 4=open (24 V DC) D12 area 3 closed output 5=closed (0 V DC) green output 5=open (24 V DC) D13 area 4 closed output 6=closed (V DC) blue output 6=open (24VDC) D14 Teach Off Inactive flashing Teach in progress The last teaching step in orange Rockwell Automation Publication 45MLA-IN002C-EN-P-20 August 7, 2020 Installation instructions for 45MLA controllers DIP switch settings DIP switches 1... 6 on the S1 DIP switch array are configured for various applications described in Table 15.