A-B 2094-BM01-S B 工控机器人备件
不模拟模型控制器45MLA-CTRLALG基本模型控制器45MLA-CTRL-BSC I/O模型控制器45ML A-CTRL RS-485控制器45MLA CTRL-485 CAN控制器45MLA-CTRL-CAN环境认证c-UL-us和CE标记适用于所有适用指令操作环境•外壳:IP54•接线板:IP20工作温度0…55°c(32…131°F)存储温度-25…+70°C(-13…+158°F)相对湿度15…95%光学状态指示器对准、目标存在、输出、输入、电源电压24V DC±15%(20.4…27.6V),最大(2级)纹波=5%电流消耗<300 mA,控制器的最大波束数,输出未连接传感器保护EN 61000-4-2、EN 61000-4-4和EN 61000-4-5;短路(SCP),和过载输出响应时间参见第2页上的响应时间输出类型NPN和PNP(推挽输出)输出模式暗操作(当连接为PNP时)输出电流最大150 mA每种输入类型下沉或源(跳线可选,默认用于连接到PNP输出)机械连接类型•弹簧加载可拆卸端子板•2 x RJ45(仅连接到灯阵列)•仅限CAN型号:用于CAN通信的两个额外RJ45连接器材料外壳ABS(FR)UL94-V0聚碳酸酯外壳所需配件45MLA灯阵列(类别号45MLA-xxxxx 0Pxx)。请参见第11页的附件。注意:这些设备仅用于物体识别,不得用于保护人身(进入保护)。警察的唯一目的是侦察目标,并利用人类保护(保护行动)最高环境温度:55°C(131°F)环境温度最高:55°F(131°C)注意:必须使用提供的索环安装电缆,以保持IP54标准。不允许允许电缆在安装环境中受到挤压或机械应力。
Not simulating model controller 45MLA-CTRLALG basic model controller 45MLA-CTRL-BSC I/O model controller 45MLA-CTRL RS-485 controller 45MLA CTRL-485 CAN controller 45MLA-CTRL-CAN environmental certification c-UL us and CE mark are applicable to all applicable command operating environments • Housing: IP54 • Terminal block: IP20 operating temperature 0... 55 ° c (32... 131 ° F) Storage temperature - 25...+70 ° C (- 13...+158 ° F) Relative humidity 15... 95% Optical status indicator alignment Target presence, output, input, power supply voltage 24V DC ± 15% (20.4... 27.6V), maximum (level 2) ripple=5%, current consumption<300 mA, maximum number of beams of the controller, output sensor protection without connection EN 61000-4-2, EN 61000-4-4 and EN 61000-4-5; Short circuit (SCP), And overload output response time See response time on page 2 Output types NPN and PNP (push-pull output) Output mode Dark operation (when connected to PNP) Output current max. 150 mA Sink or source of each input type (jumper optional, default for connecting to PNP output) Mechanical connection type • Spring loaded removable terminal board • 2 x RJ45 (only connected to lamp array) • Only for CAN models: two additional RJ45 connector material shells for CAN communication ABS (FR) UL94-V0 polycarbonate shell accessories 45MLA lamp array (category number 45MLA-xxxxx 0Pxx). Please refer to the attachment on page 11. Note: These devices are only used for object identification and should not be used for personal protection (entry protection). The sole purpose of the police is to detect the target and use human protection (protection operation). The maximum ambient temperature is 55 ° C (131 ° F). The maximum ambient temperature is 55 ° F (131 ° C). Note: the cable must be installed with the grommet provided to maintain the IP54 standard. The cable shall not be allowed to be subjected to extrusion or mechanical stress in the installation environment.