RPM定义了在电机铭牌基准频率、额定电流、基准电压和额定温度下运行时的额定转速。这用于计算滑移。【电机NP功率】电机铭牌功率与其他铭牌值一起用于计算电机参数的默认值,以便于调试过程。这可能是以马力或千瓦为单位输入的,如前一个参数中所选,或以千瓦为单位(对于某些目录号),以马力为单位(其他目录号)。[电机NP功率单位]电机的额定功率可以以马力或千瓦为单位输入。此参数确定以下参数的单位。【电机极数】电机极数仅允许偶数(铭牌上可能会出现,也可能不会出现)。74自动化出版物PFLEXRM002DENE2013年8月第1章详细驱动配置和操作图24IL高过载在额定输出电流下连续运行后的图示,过载可以是150%额定输出电流(IH)持续1分钟,只要随后是小于额定电流的负载周期。
示例:
如果占空比每10分钟需要1分钟150%的额定输出电流,则剩余的9分钟必须为大约92%的额定电流或更低,以保持输出电流小于100%。如果要求为60分钟中的1分钟,则剩余的59分钟必须约为98%额定电流或更低。1分钟9分钟1.1 x IL时间电流IL自动化出版物PFLEXRM002DENE2013年8月75详细驱动器配置和操作第1章电机启动/停止注意事项输入接触器输出接触器安装一般来说,驱动器应安装在垂直方向的金属平表面上。如果考虑其他方向,请联系工厂获取更多数据。有关安装说明和限制,请参阅PowerFlex 700S驱动器用户手册出版物20DUM001中的第1章安装/接线。
Motor nameplate
RPM defines the rated speed when operating at the motor nameplate reference frequency, rated current, reference voltage and rated temperature. This is used to calculate slip. [Motor NP power] The motor nameplate power is used together with other nameplate values to calculate the default values of motor parameters, so as to facilitate the commissioning process. This may be entered in horsepower or kilowatt units, as selected in the previous parameter, or in kilowatt units (for some catalog numbers), or in horsepower units (for other catalog numbers). [Motor NP power unit] The rated power of the motor can be input in horsepower or kilowatt. This parameter determines the units for the following parameters. [Number of motor poles] The number of motor poles can only be even (may or may not appear on the nameplate). 74 Automation publication PFLEXRM002DENE, August 2013, Chapter 1, Detailed Drive Configuration and Operation Diagram 24IL Diagram of High Overload after Continuous Operation at Rated Output Current. Overload can be 150% of rated output current (IH) for 1 minute, as long as the subsequent load cycle is less than rated current.
Example:
If the duty cycle requires 150% of the rated output current for 1 minute every 10 minutes, the remaining 9 minutes must be about 92% of the rated current or less to keep the output current less than 100%. If 1 minute out of 60 minutes is required, the remaining 59 minutes must be approximately 98% of rated current or less. 1 minute 9 minutes 1.1 x IL time current IL automation publication PFLEXRM002DENE August 75, 2013 Detailed driver configuration and operation Chapter 1 Motor start/stop considerations Input contactor Output contactor installation Generally speaking, the driver should be installed on a metal flat surface in the vertical direction. If you are considering other directions, please contact the factory for more data. For installation instructions and limitations, refer to Chapter 1 Installation/Wiring in PowerFlex 700S Drive Owner's Manual publication 20DUM001.