DS200KLDBG1ABC DCS工控模块备件
I/O规范
Experion Series-C I/O规范,EP03-490-520 47版本1.5霍尼韦尔专有2021 12月详细规范-带OWD1参数规范的数字输入开路电压电源电压(最大26 VDC)闭合触点电流7 mA(最大)闭合触点检测3.1 mA<I<7 mA开路触点检测0.9 mA<I<2.0 mA开路检测I<0.9 mA事件序列(SOE)的数字输入分辨率1ms(任何/所有通道)注1有关OWD功能的适当场电阻器配置,请参阅《用户指南》。详细规范-无OWD的数字输入参数规范开路电压电源电压(最大26 VDC)闭合触点电流7 mA(最大)闭合触点检测I>3.2 mA断开触点检测I<2.0 mA事件序列(SOE)数字输入分辨率1ms(任何/所有通道)Experion Series C I/O规范,EP03-490-520 48版本1.5霍尼韦尔专有2021 12月
详细规范-数字输出
参数规范每个模块2最大32个输出通道(带或不带开路检测)输出型固态电源,短路保护3负载电流断开负载电流接通<0.1 mA每个通道最小到0.5 A每个通道最大9 A每个模块1最大接通电压24 V(典型),负载电流@0.5 A关闭状态电压0德尔塔V™ I/O子系统易于安装和维护。降低资本设备成本减少安装时间和费用提高生产率提高过程可用性简介传统I/O是一种模块化子系统,在安装过程中提供灵活性。它被设计为安装在现场,靠近您的设备。传统I/O配有功能和现场接线保护键,以确保正确的I/O卡始终插入相应的接线板。模块化、保护密钥和即插即用功能使DeltaV™ 传统I/O是您的过程控制系统的明智选择。DeltaV M系列传统I/O 2022年10月www.emerson。
I/O Specification
Experion Series-C I/O specification, EP03-490-520 47 version 1.5 Honeywell proprietary December 2021 detailed specification - Digital input open circuit voltage power supply voltage (maximum 26 VDC) with OWD1 parameter specification Closed contact current 7 mA (maximum) Closed contact detection 3.1 mA<I<7 mA Open contact detection 0.9 mA<I<2.0 mA Open circuit detection I<0.9 mA Event sequence (SOE) Digital input resolution 1 ms (any/all channels) Note 1 Appropriate field resistor configuration for OWD function, Refer to the User Guide. Detailed specification - specification of digital input parameters without OWD Open circuit voltage Power supply voltage (maximum 26 VDC) Closed contact current 7 mA (maximum) Closed contact detection I>3.2 mA Open contact detection I<2.0 mA Sequence of events (SOE) Digital input resolution 1 ms (any/all channels) Experience Series C I/O specification, EP03-490-520 48 version 1.5 Honeywell proprietary December 2021
Detail Specification - Digital Output
Parameter specification: Each module 2 has a maximum of 32 output channels (with or without open circuit detection), output solid state power supply, short-circuit protection 3, load current disconnection, load current connection<0.1 mA, each channel minimum to 0.5 A, each channel maximum 9 A, each module 1 maximum connection voltage 24 V (typical), load current @ 0.5 A, closing state voltage 0 delta V ™ The I/O subsystem is easy to install and maintain. Reduce capital equipment costs Reduce installation time and costs Improve productivity Improve process availability Introduction Traditional I/O is a modular subsystem that provides flexibility during installation. It is designed to be installed on-site, close to your equipment. Traditional I/O is equipped with functional and field wiring protection keys to ensure that the correct I/O card is always plugged into the appropriate terminal block. Modularity, protection keys, and plug and play enable DeltaV ™ Traditional I/O is a wise choice for your process control system. DeltaV M Series Traditional I/O October 2022 www.emerson.