您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

机器人模块卡件6SE7023-8TP60-Z

机器人模块卡件6SE7023-8TP60-Z

机器人模块卡件6SE7023-8TP60-Z电流输出(4至20 mA)–HART(FEX100)变型+–有关HART协议通信的详细信息,请参阅IM/WMP电流输出(4-20 mA)–哈特(FEX10)变型RS485通信–PROFIBUS(FEX100-DP)和MODBUS(FEX100-MB)变型PROFIBUS/MODBUS RS485 A1/B1–In A2/B2–Out Screen cla...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

机器人模块卡件6SE7023-8TP60-Z

    机器人模块卡件6SE7023-8TP60-Z

    电流输出

    (4至20 mA)–HART(FEX100)变型+–有关HART协议通信的详细信息,请参阅IM/WMP电流输出(4-20 mA)–哈特(FEX10)变型RS485通信–PROFIBUS(FEX100-DP)和MODBUS(FEX100-MB)变型PROFIBUS/MODBUS RS485 A1/B1–In A2/B2–Out Screen clamp测试点访问注释。典型的DVM探针可以接近(安装)PCB的测试孔。IC+IC–O/P1 O/P2 COM 4至20 mA频率输出未使用未使用O/P3报警输出*这两个测试点仅连接在HART FEX100背板上(它们存在于PROFIBUS FEX100-DP/MODBUS FEX100-MB背板上,但未连接)WATERMASTER电磁流量计| DS/WM-EN REV。Y 17-数字通信变送器具有以下数字通信选项。HART协议该装置在HART通信基金会注册。端子块处的多点连接HART连接4 mA电流输出(多点连接)4至20 mA电流输出HART调制解调器(FSK[Frequency Shift Keyed]-modem),用于连接到PC时的HART通信。HART调制解调器将模拟4-20 mA信号转换为数字输出信号(贝尔标准202),并使用USB(或RS232C)连接器连接到PC。最大信号振幅1.2 mA电流输出负载最小250W,最大=560W AWG 24绞合电缆最大电缆长度1500 m(4921 ft.)波特率1.200波特系统集成WaterMaster可以使用任何框架应用程序(如ABB AssetVision或类似的第三方应用程序)集成到控制系统和配置设备中。用于WaterMaster的ABB设备类型管理器(DTM)为访问设备参数、配置和操作设备以及诊断问题提供了统一的结构。FDT(现场设备工具)技术使所有现场设备和主机系统之间的通信和配置接口标准化。PROFIBUS DP协议PROFIBU是一种独立于制造商的开放式现场总线标准,适用于制造、过程和建筑自动化的广泛应用。国际标准EN 50170确保了制造商的独立性和开放性。PROFIBUS DP ID号0x3431替代标准ID号0x9701或0x9741直接在设备上配置软件资产Vision Basic(+PROFIBUS-DP-DTM)传输信号精度符合IEC 61158-2电缆屏蔽,绞合电缆(精确到IEC 61158-2,类型A或B)所有设备都以如下所示的总线结构(“线路”)连接。最多可以链接32个工作站(主站或从站)以创建一个“段”,但建议不要在单个段上安装超过16个设备。段的每一端必须由有源总线端接电阻器端接

    备用电源

    两个总线终端必须始终通电,以确保无故障运行,因此强烈建议将其连接到备用电源。可以使用总线放大器(中继器)和分段耦合器来扩展网络。操作级工程师操作控制WaterMaster FEX100-DP DP/PA链路PROFIBUS-DP PROFIBUS PA主站级从站级18 WaterMaster电磁流量计| DS/WM-EN REV.Y-…数字通信系统集成WaterMasters的GSD文件指定了设备特定标识号3431。它符合PROFIBU标准,以精确定义的格式提供每种仪器的清晰和全面描述。这使得系统配置工具能够在配置PROFIBUS总线系统时自动使用信息。ABB GSD文件(识别号3431)分为两部分:•通用规范–设备标识,以及硬件和软件版本、支持的波特率和监控时间的可能时间间隔。•DP从机相关规范–关于设备特定配置的用户参数块的信息,以及包含可与PROFIBUS主设备循环交换的输入和输出数据细节的模块。WaterMaster GSD文件(ABB_3431.GSD)可从ABB网站www.ABB下载。com/fieldbus(请参阅PROFIBUS DP现场设备的链接)。MODBUS协议MODBUS是一个开放标准,由一个名为MODBUS组织(www.MODBUS.org)的独立设备制造商集团拥有和管理。使用MODBUS协议,不同制造商的设备在同一通信总线上交换信息,而不需要特殊的接口设备。WaterMaster FEX100-MB遵循Modbus Over Serial Line V1.02的规范,使用2线TIA/EIA-485(RS485)物理层。

    Current output

    (4 to 20 mA) – HART (FEX100) variant+– For details of HART protocol communication, see IM/WMP Current Output (4-20 mA) – Hart (FEX10) variant RS485 Communication – PROFIBUS (FEX100-DP) and MODBUS (FEX100-MB) variant PROFIBUS/MODBUS RS485 A1/B1 – In A2/B2 – Out Screen clamp Test Point Access Note. A typical DVM probe can access (mount) the test hole of the PCB. IC+IC – O/P1 O/P2 COM 4 to 20 mA frequency output not used Not used O/P3 alarm output * These two test points are only connected to the HART FEX100 backplane (they exist on the PROFIBUS FEX100-DP/MODBUS FEX100-MB backplane, but are not connected) WATERMASTER electromagnetic flowmeter | DS/WM-EN REV. The Y 17 Digital Communication Transmitter has the following digital communication options. HART Protocol The device is registered with the HART Communication Foundation. The multipoint connection HART at the terminal block connects a 4 mA current output (multipoint connection) 4 to 20 mA current output HART modem (FSK [Frequency Shift Keyed] - modem) for HART communication when connected to a PC. A HART modem converts an analog 4-20 mA signal to a digital output signal (Bell Standard 202) and connects to a PC using a USB (or RS232C) connector. Maximum signal amplitude 1.2 mA Current output load Minimum 250W, Maximum=560W AWG 24 twisted cable Maximum cable length 1500 m (4921 ft.) Baud rate 1.200 baud System integration WaterMaster can be integrated into the control system and configuration equipment using any framework application (such as ABB AssetVision or similar third-party applications). ABB Device Type Manager (DTM) for WaterMaster provides a unified structure for accessing device parameters, configuring and operating devices, and diagnosing problems. FDT (Field Device Tools) technology standardizes the communication and configuration interfaces between all field devices and host systems. PROFIBUS DP protocol PROFIBU is an open field bus standard independent of manufacturers, which is suitable for wide applications of manufacturing, process and building automation. The international standard EN 50170 ensures the independence and openness of manufacturers. The PROFIBUS DP ID No. 0x3431 replaces the standard ID No. 0x9701 or 0x9741. The Vision Basic (+PROFIBUS-DP-DTM) directly configures software assets on the device. The transmission signal accuracy conforms to IEC 61158-2 cable shielding. The twisted cable (accurate to IEC 61158-2, type A or B). All devices are connected with the bus structure ("line") shown below. You can link up to 32 workstations (master or slave) to create a "segment", but it is recommended that you do not install more than 16 devices on a single segment. Each end of the segment must be terminated by an active bus termination resistor

    emergency power supply

    Both bus terminals must be powered at all times to ensure trouble free operation, so it is strongly recommended that they be connected to a backup power source. The network can be extended using bus amplifiers (repeaters) and segment couplers. Operation level engineer operates and controls WaterMaster FEX100-DP DP/PA link PROFIBUS-DP PROFIBUS PA master level slave station level 18 WaterMaster electromagnetic flowmeter | DS/WM-EN REV. Y -... GSD file of digital communication system integration WaterMasters specifies equipment specific identification number 3431. It conforms to the PROFIBU standard and provides a clear and comprehensive description of each instrument in a precisely defined format. This allows the system configuration tool to automatically use information when configuring a PROFIBUS bus system. ABB GSD file (ID 3431) is divided into two parts: • General specification – equipment identification, and possible time intervals for hardware and software versions, supported baud rates, and monitoring time. • DP slave related specifications – information about the user parameter block of the device specific configuration, and the module containing the details of the input and output data that can be cyclically exchanged with the PROFIBUS master. WaterMaster GSD files (ABB_3431. GSD) can be found on ABB website at www ABB download. Com/fieldbus (see the link to the PROFIBUS DP field device). MODBUS protocol MODBUS is an open standard, which is owned and managed by an independent equipment manufacturer group named MODBUS organization (www.MODBUS. org). Using MODBUS protocol, devices from different manufacturers exchange information on the same communication bus without special interface devices. The WaterMaster FEX100-MB follows the specification of Modbus Over Serial Line V1.02 and uses the 2-wire TIA/EIA-485 (RS485) physical layer.

    23.jpg

    21.jpg

    14.jpg



    品牌:ABB

    型号: 6SE7023-8TP60-Z

    产地:瑞士

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号