您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

3BSE004160R1 PFTL101A称重传感器

3BSE004160R1 PFTL101A称重传感器

3BSE004160R1 PFTL101A称重传感器 一般信息产品编号:ABB型号名称:CI541V1目录描述:CI541 V1 CI541 V2 Profibus接口子模块附加信息ABB型号型号:CI541A V1目录说明:CI542 V1 CI54 V1 Profibus接口子模块核心信用证:0.00原产国:瑞典(SE)德国(DE)海关税号:85389091毛重:0.17 kg发票描述:CI5...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

3BSE004160R1 PFTL101A称重传感器

    3BSE004160R1 PFTL101A称重传感器

     一般信息产品编号:


    ABB型号名称:CI541V1目录描述:CI541 V1 CI541 V2 Profibus接口子模块附加信息ABB型号型号:CI541A V1目录说明:CI542 V1 CI54 V1 Profibus接口子模块核心信用证:0.00原产国:瑞典(SE)德国(DE)海关税号:85389091毛重:0.17 kg发票描述:CI541V1 Profibus接口子模块定制:无介质描述:CI551V1现场总线接口子模块最小订单数量:1件订单数量:一件包装级别1单位:0纸箱零件类型:新产品名称:-产品净重:0.17 kg仅报价:无销售计量单位:件简短描述:-零件和服务控制系统Advant OCS with Master SW控制器Advant控制器110通信模块部件和服务控制系统Advant OCS带主软件控制器带主软件控制器Advant Controller 450RMC Advant控制器450RMC 2.x通信模块  (仓库):配送中心中心库存美国DEOSCEXPU SGRL4124EXPU SGRL4414FEXPU SELOGVEXPU UNSPSC:39120000 


    伺服驱动器


    概述MicroFlex e190和MotiFlex e180伺服驱动器的58xx固件系列的推出带来了Modbus TCP客户端功能。这使得这些功能强大且灵活的驱动器能够连接到各种Modbus TCP服务器设备,如条形码扫描仪、PLC、HMI和ABB自己的Modbus TCP/IP I/O扩展模块、CI521-MODTCP和CI522-MODTCP。驱动器最多可连接2个CI521或CI522模块,每个模块最多可安装10个S500 I/O扩展模块,这些模块只需插入前一个模块的侧面即可。如果读者还不熟悉e190和e180驱动系列,建议他们熟悉安装手册3AXD50000037326(MicroFlex e190安装手册)和3AXD00000019946(MotiFlex e180安装手册)的内容。有关CI521和CI522模块的详细信息,请参阅Automation Builder帮助系统。S500扩展模块的连接信息也包含在Automation Builder帮助系统中。这些模块可与以下基本单元一起使用:·TU507-ETH(螺纹端子连接)·TU508-ETH(弹簧/笼式夹具连接)先决条件为了正确操作Modbus TCP I/O模块,请确保安装以下固件:MicroFlex e190:5868或更高版本MotiFlex e180:5811或更高(尽管建议使用5868以利用最新功能)CI521/CI522:V3.1.7或更高版本(这些模块上安装的固件版本可以通过从设备读取Modbus寄存器6和7来确定。例如,如果模块连接到驱动器并配置为服务器设备0,请输入…?十六进制MODBUSTCP16(0,6)?工作台命令行的十六进制MODBUSTCP16(0,7)。例如,这些命令应返回值5603和107(56=ASCII V,后面是版本03 01 07)。如果Modbus I/O基本模块需要更新,请联系当地ABB支持办公室(AC500 PLC程序可在现场执行此更新,但可能需要将其返回以进行升级)。

    General Information Product Number:

    ABB Model Name: CI541V1 Directory Description: CI541 V1 CI541 V2 Profibus Interface Submodule Additional Information ABB Model Model: CI541A V1 Directory Description: CI542 V1 CI54 V1 Profibus Interface Submodule Core Letter of Credit: 0.00 Country of Origin: Sweden (SE) Germany (DE) Customs Duty No.: 85389091 Gross Weight: 0.17 kg Invoice Description: CI541V1 Profibus Interface Submodule Customization: No Media Description: CI551V1 Fieldbus Interface Submodule Minimum Order Quantity: 1 piece Order Quantity: 1 piece Packaging Level 1 Unit: 0 Carton Part Type: New Product Name: - Product Net Weight: 0.17 kg Quote Only: No Sales Measurement Unit: piece Short Description: - Parts and Service Control System AdvantOCS with Master SW Controller Advant Controller 110 Communication module components and service control system AdvantOCS with main software controller AdvantController 450RMC AdvantController 450RMC 2. x Communication module (warehouse): distribution center inventory U.S. DEOSCEPU SGRL4124EXPU SGRL4414FEXPU SELOGVEXPU UNSPSC: 39120000

    Servo driver

    Overview The introduction of the 58xx firmware series of MicroFlex e190 and MotiFlex e180 servo drives brings Modbus TCP client functionality. This enables these powerful and flexible drivers to connect to various Modbus TCP server devices, such as barcode scanners, PLC, HMI and ABB's own Modbus TCP/IP I/O expansion module, CI521-MODTCP and CI522-MODTCP. The drive can connect up to 2 CI521 or CI522 modules, and each module can install up to 10 S500 I/O expansion modules. These modules only need to be inserted into the side of the previous module. If the reader is not familiar with the e190 and e180 drive series, it is recommended that they be familiar with the contents of the Installation Manual 3AXD50000037326 (MicroFlex e190 Installation Manual) and 3AXD00000019946 (MotiFlex e180 Installation Manual). For more information about the CI521 and CI522 modules, see the Automation Builder help system. The connection information of the S500 expansion module is also included in the Automation Builder help system. These modules can be used with the following basic units: · TU507-ETH (screw terminal connection) · TU508-ETH (spring/cage clamp connection) prerequisites In order to operate the Modbus TCP I/O module correctly, Make sure to install the following firmware: MicroFlex e190:5868 or later MotiFlex e180:5811 or later (although 5868 is recommended to take advantage of the latest features) CI521/CI522: V3.1.7 or later (The firmware version installed on these modules can be determined by reading Modbus registers 6 and 7 from the device. For example, if the module is connected to a drive and configured as a server device 0, enter...? Hex MODBUSTCP16 (0,6)? Hexadecimal MODBUSTCP16 (0,7) of the workbench command line. For example, these commands should return values 5603 and 107 (56=ASCII V, followed by version 03 01 07). If the Modbus I/O basic module needs to be updated, please contact your local ABB support office (the AC500 PLC program can perform this update in the field, but it may need to be returned for upgrade).

    8.jpg

    QQ图片20220408093546.png

    d082d79904e378397cc59202556710a7.jpg


    品牌:ABB

    型号:3BSE004160R1 PFTL101A 

    产地:瑞士

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号