1VCR007346 G0012操作触摸屏,ABB使用配置手册
用于在PAC系统中使用模拟扩展器时的故障报告RX7i机架,当基座位于插槽4和扩展器位于插槽11中。在这种情况下,出现故障的扩展器始终显示为插槽2,电路号将根据扩展器使用的插槽显示,如下表。显示每个通道的输入/输出参考地址如果用户将硬件配置存储到闪存,则表示“逻辑/配置电源”设置为“始终闪烁”或“有条件”Flash”,然后在编程软件时,硬件配置将不相等不会验证为相等。
1VCR007346 G0012操作触摸屏控制器和IO故障表可能需要清除两次以清除故障状态需要清除控制器和IO故障表以占用CPU退出停止/故障模式。如果其中一个表包含重复出现的故障,则清除表格的顺序可能很重要。如果CPU是清除两个表后,仍处于停止/故障模式,请尝试清除故障表。
当使用使用以下命令的VME内存区域启用块传输时,使用程序类型AM代码的VME模块程序类型AM代码之一,Rx7i CPU有时会生成访问相关VME的块传输(BLT和MBLT)循环记忆力因此,如果您将VME内存区域配置为使用程序类型AM代码之一(AM代码3Ah、3Eh、0Ah或0Eh),请确保遵守以下两条规则中的至少一条:a) 内存区域的接口类型参数不得设置为“Qword访问(64位)”,并且VME块传输参数必须设置为“禁用”。
-ORb)系统可能不包含任何“程序”和“数据”VME内存VME地址重叠的区域。(如果有多个VME如果模块响应BLT或MBLT循环,则可能会出现系统错误结果。)一旦强制开启或强制关闭存储到PLC,用户就无法通过下载直接从强制打开切换到强制关闭,反之亦然初始值。用户可以通过下载关闭强制,然后然后通过另一次下载更改力的开启或关闭。
For fault reporting when an analog expander is used in a PACSystems
RX7i rack, a special case exists when the base is in slot 4 and an
expander is present in slot 11. In this case, the slot number for a faulty
expander is always displayed as slot 2, and the circuit number will
display according to the slot used for the expander, as shown in the
following table. The I/O reference address for each channel is displayed
as blankIf the user stores a hardware configuration to flash which indicates that
“Logic/Config Power up Source” is set to “Always Flash” or “Conditional
Flash” and then subsequently changes the name of the target in the
programming software, the hardware configuration will go Not Equal and
will not Verify as equal.
Controller and IO fault tables may need to be
cleared twice to clear faulted state
Both Controller and IO fault tables need to be cleared to take the CPU
out of Stop/Fault mode. If one of the tables contains a recurring fault, the
order in which the tables are cleared may be significant. If the CPU is
still in Stop/Fault mode after both tables are cleared, try clearing the fault
tables again.
VME modules using program type AM codes When Block Transfers are enabled with a VME memory region that uses
one of the program type AM Codes, the Rx7i CPU sometimes generates
block transfer (BLT & MBLT) cycles to access the associated VME
memory. Therefore, if you have a VME memory region configured to use
one of the program type AM Codes (AM Codes 3Ah, 3Eh, 0Ah, or 0Eh),
be sure to follow at least one of these two rules:
a) The memory region's Interface Type parameter must not be set to
"Qword Access (64-bit)", and the VME Block Transfer parameter must
be set to "Disabled".
-ORb) The system may not contain any "program" and "data" VME memory
regions with overlapping VME addresses. (If more than one VME
module were to respond to a BLT or MBLT cycle, a system error could
result.)Once a force on or force off has been stored to the PLC, the user cannot
switch from force on to force off or vice-versa directly by downloading
initial values. The user can turn off the force by doing a download, and
then change the force on or off by another download.