在使用以太网通信之前,需要配置IP地址CPU模块内的以太网接口无法在网络上运行,除非提供有效的IP地址已配置。必须在实际网络之前配置必要的以太网寻址信息活动使用以下方法之一:■ 使用通过PLC电源连接的PLC编程器执行初始配置串行端口。■ 将串行终端连接到CPU374的station manager端口。然后使用CHSOSW命令输入临时IP地址。
5SXE08-0166可控硅模块然后可以通过网络访问以太网接口(例如通过以太网PLC程序员)。有关详细信息,请参阅TCP/IP以太网通信站GFK-1186。■ 使用以太网为模块临时分配一个IP地址。有关详细信息,请参阅TCP/IP以太网通信站管理器手册,GFK-1186,附录D。正确的IP地址始终至关重要CPU374的嵌入式以太网接口必须配置正确的IP地址,以确保正确的TCP/IP以太网中的操作。使用不正确的IP地址可能会中断CPU374和网络上的其他节点。请参阅本系列的TCP/IP以太网通信90 PLC用户手册,GFK1541,了解IP寻址的重要信息。CPU374可能会意外地消耗生成到组地址的EGD交换CPU374仅根据生产者ID和交换ID使用EGD交换。与其他类型不同在GE Fanuc产品中,CPU374不基于IP多播组过滤消耗的交换机住址使用时,组号不得用作区分EGD消费者的手段CPU374。存储配置时,以太网程序员可能会短暂失去通信存储包含以太网配置值的PLC配置可能需要以太网接口
重新启动自身以使用任何更改的配置值。当Ethernet接口重新启动时
Configuration of IP Address is Required Before Using Ethernet Communications
The Ethernet interface within the CPU module cannot operate on a network until a valid IP address is
configured. The necessary Ethernet addressing information must be configured prior to actual network
operation. Use one of the following methods:
■
Perform the initial configuration using a PLC Programmer connected through the PLC power supply
serial port.
■
Connect a serial terminal to the station manager port of the CPU374. Then use the CHSOSW command
to enter a temporary IP address. The Ethernet Interface can then be accessed over the network (such as
by an Ethernet PLC Programmer). For details, see the TCP/IP Ethernet Communications Station
Manager Manual, GFK-1186.
■
Temporarily assign an IP address to the module using the Ethernet network. For details, see the TCP/IP
Ethernet Communications Station Manager Manual, GFK-1186, Appendix D.
Proper IP Addressing is Always Essential
The CPU374’s embedded Ethernet Interface must be configured with the correct IP Address for proper
operation in a TCP/IP Ethernet network. Use of incorrect IP addresses can disrupt network operation for the
CPU374 and for other nodes on the network. Refer to the TCP/IP Ethernet Communications for the Series
90 PLC User’s Manual, GFK1541 for important information on IP addressing.
CPU374 May Unexpectedly Consume EGD Exchanges Produced To a Group Address
The CPU374 consumes EGD exchanges based solely on their producer ID and exchange ID. Unlike other
GE Fanuc products, the CPU374 does not filter consumed exchanges based on the IP multicast group
address. Group numbers must not be used as the means of distinguishing EGD consumers when using the
CPU374.
Ethernet Programmer May Briefly Lose Communications When Configuration Stored
Storing a PLC configuration containing Ethernet configuration values may require the Ethernet interface to
restart itself in order to use any changed configuration values. When the Ethernet interface restarts, an