GJR2390211R45

GJR2390211R45模块卡件,GJR2390211R45用户手册电磁兼容性(EMC)欧洲EMC指令89/336/EEC符合:EN 50081-2排放标准EN 50082-2抗扰度标准EN 61326附录A(工业级)CISPR 11,工业科学和医学(ISM)射频设备—电磁干扰特性-限值和测量方法满足A类限制IEC 61000-4-2 ESD抗扰度触点4 kV,空气8 kVIEC 61000-4...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

GJR2390211R45

    GJR2390211R45模块卡件,GJR2390211R45用户手册

    电磁兼容性(EMC)

    欧洲EMC指令89/336/EEC符合:EN 50081-2排放标准

    EN 50082-2抗扰度标准EN 61326附录A(工业级)

    CISPR 11,工业科学和医学(ISM)射频设备—电磁干扰特性

    -限值和测量方法

    满足A类限制IEC 61000-4-2 ESD抗扰度触点4 kV,空气8 kV

    83SR04C-E GJR2390200R1411 GJR2390211R45 (2).jpg

    IEC 61000-4-3辐射场抗扰度

    80至1000 MHz时为10 V/m

    GJR2390211R45模块卡件IEC 61000-4-4电气快速瞬态/突发抗扰度

    2 kV输入/输出、直流电源和通信线

    IEC 61000-4-5浪涌抗扰度

    交流和直流电源线上的2kV;输入/输出1kV和通信线路

    电磁兼容性(续)

    GJR2390211R45模块卡件IEC 61000-4-6传导抗扰度射频引起的干扰领域

    输入/输出150 kHz至80 MHz时为10 V(rms),直流电源和通信线路

    IEC 61000-4-8工频磁性现场抗扰度50和60 Hz时为30 A/m

    产品安全性美国保险商实验室(UL)和加拿大

    UL/UL-C被列为适用于UL/UL-C列出的I类,A-D组;

    第2分部;温度代码T4外壳基于系统。这些模块也是UL

    UL-C被列为提供非易燃通信I类A-D组危险电路连接到指定位置时的位置如上所述的I/A Series®处理器模块

    在I/A系列DIN导轨安装子系统用户指南(B0400FA)。通信电路也满足中定义的2类要求

    使用条件如I/A系列DIN导轨安装子系统用户指南(B0400FA)。

    欧洲低压指令73/23/EEC和爆炸性环境(ATEX)指令94/9/ECCENELEC(DEMKO)认证为

    CENELEC中使用的EEx nA[nL]IIC T4认证的2区外壳认证为

    为2区IIC组非易燃现场电路供电的相关设备,潜在爆炸性环境

    连接到指定的I/A系列处理器I/A系列DIN中所述的模块轨道安装子系统用户指南

    Regulatory Compliance
    ELECTROMAGNETIC COMPATIBILITY (EMC)
    European EMC Directive 89/336/EEC
    Meets: EN 50081-2 Emission standard
    EN 50082-2 Immunity standard
    EN 61326 Annex A (Industrial Levels)
    CISPR 11, Industrial Scientific and Medical
    (ISM) Radio-frequency Equipment -
    Electromagnetic Disturbance Characteristics
    - Limits and Methods of Measurement
    Meets Class A Limits
    IEC 61000-4-2 ESD Immunity
    Contact 4 kV, air 8 kV
    IEC 61000-4-3 Radiated Field Immunity
    10 V/m at 80 to 1000 MHz
    IEC 61000-4-4 Electrical Fast
    Transient/Burst Immunity
    2 kV on I/O, dc power and communication
    lines
    IEC 61000-4-5 Surge Immunity
    2kV on ac and dc power lines; 1kV on I/O
    and communications lines
    ELECTROMAGNETIC COMPATIBILITY (CONT.)
    IEC 61000-4-6 Immunity to Conducted
    Disturbances Induced by Radio frequency
    Fields
    10 V (rms) at 150 kHz to 80 MHz on I/O,
    dc power and communication lines
    IEC 61000-4-8 Power Frequency Magnetic
    Field Immunity
    30 A/m at 50 and 60 Hz
    PRODUCT SAFETY
    Underwriters Laboratories (UL) for U.S. and
    Canada
    UL/UL-C listed as suitable for use in
    UL/UL-C listed Class I, Groups A-D;
    Division 2; temperature code T4 enclosure
    based systems. These modules are also UL
    and UL-C listed as associated apparatus for
    supplying non-incendive communication
    circuits for Class I, Groups A-D hazardous
    locations when connected to specified
    I/A Series® processor modules as described
    in the I/A Series DIN Rail Mounted
    Subsystem User’s Guide (B0400FA).
    Communications circuits also meet the
    requirements for Class 2 as defined in
    Article 725 of the National Electrical Code
    (NFPA No.70) and Section 16 of the
    Canadian Electrical Code (CSA C22.1).
    Conditions for use are as specified in the
    I/A Series DIN Rail Mounted Subsystem
    User’s Guide (B0400FA).
    European Low Voltage Directive 73/23/EEC
    and Explosive Atmospheres (ATEX) directive
    94/9/EC
    CENELEC (DEMKO) certified as
    EEx nA [nL] IIC T4 for use in CENELEC
    certified Zone 2 enclosure certified as
    associated apparatus for supplying non
    incendive field circuits for Zone 2, Group IIC,
    potentially explosive atmospheres when
    connected to specified I/A Series processor
    modules as described in the I/A Series DIN
    Rail Mounted Subsystem User’s Guide


    品牌:ABB

    型号:GJR2390211R45

    产地:瑞士

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号