您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:xiamen2018@foxmail.com

主页 > 产品中心 > ICS TRIPLEX

ICS TRIPLEX

ABB >>

A-B>>

GE>>

BENTLY>>

ICS TRIPLEX 9402机械设备卡件

ICS TRIPLEX 9402机械设备卡件

ICS TRIPLEX 9402机械设备卡件t或通过通信发出停止命令,参见第6–6页第6.2.4节:功能代码05:执行操作。n电源系统n[ENTER]了解更多标称系统频率:60 Hz范围:50 Hz,60 Hz,可变系统相位顺序:ABC范围:ABC,ACB速度2相位顺序:ABC范围:ABC、ACB仅当启用双速电机保护时才可见n串行通信控制n[ENTEP]了解更多串行通信控制:关闭范围:打开、关闭分...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

ICS TRIPLEX 9402机械设备卡件

    ICS TRIPLEX 9402机械设备卡件

    t或通过通信发出停止命令,参见第6–6页第6.2.4节:功能代码05:执行操作。n电源系统n[ENTER]了解更多标称系统频率:60 Hz范围:50 Hz,60 Hz,可变系统相位顺序:ABC范围:ABC,ACB速度2相位顺序:ABC范围:ABC、ACB仅当启用双速电机保护时才可见n串行通信控制n[ENTEP]了解更多串行通信控制:关闭范围:打开、关闭分配启动控制继电器:辅助2范围:辅助2、辅助2和辅助3,辅助3 ENTER ESCAPE♥信息ESCAPE MESSAGE ESCAPE ENTER ESCAPE♥MESSAGE ESCAPE GE Multilin 469电机管理继电器4-15 4设定值4.3 S2系统设置4 4.3.5降低电压路径:设定值×S2系统设置×降低电压469可以控制降低电压启动器从降低到满电压的过渡。该转换可能基于“仅限电流”、“电流和计时器”或“电流或计时器”(以先到者为准)。当469测量到无电机电流向某个电机电流值的转变时,假设会发生“启动”(通常电流会迅速上升到超过FLA的值,例如3×FLA)。此时,REDUCED VOLTAGE START TIMER(降低电压启动定时器)用编程值(秒)初始化。•如果选择“仅限电流”,当电机电流低于用户编程的转换水平时,将通过激活指定的输出继电器1秒来启动转换。如果计时器在转换启动之前到期,则将发生不完整顺序跳闸,激活指定的跳闸继电器。•如果选择“电流或定时器”,当电机电流低于用户编程的转换水平时,将通过激活指定的输出继电器1秒来启动转换。如果计时器在转换启动之前到期,则无论如何,转换都将启动。•如果选择了“电流和定时器”,当电机电流低于用户编程的转换水平且定时器到期时,将通过激活指定的输出继电器1秒来启动转换。如果计时器在电流低于过渡电平之前到期,则将发生不完整顺序跳闸,激活指定的跳闸继电器。图4–1:降压启动接触器控制电路n降压n[ENTER]更多降压启动:关闭范围:打开,关闭分配控制继电器:辅助3范围:辅助2、辅助2和辅助3、辅助3转换开启:仅限电流范围:电流或定时器、电流和定时器分配跳闸继电器:跳闸范围:跳闸、跳闸和辅助2、跳闸和Aux2和辅助3,跳闸和辅助3降压启动电平:100%FLA范围:25至300%,步进1降压启动定时器:200 s范围:1至600 s,步进为1回车退出信息退出信息退出消息退出消息退出808724A1.CDR CC1 CC2 469块跳闸停止启动降压接触器全电压接触器CC1密封469 R3辅助CC2密封4-16 469电机管理继电器GE Multiline 4.3 S2系统设置4

    t or stop command via communications, see Section 6.2.4: Function Code 05: Execute Operation on page 6–6. n POWER SYSTEM n [ENTER] for more NOMINAL SYSTEM FREQUENCY: 60 Hz Range: 50 Hz, 60 Hz, Variable SYSTEM PHASE SEQUENCE: ABC Range: ABC, ACB SPEED2 PHASE SEQUENCE: ABC Range: ABC, ACB Seen only if 2-Speed Motor Protection is enabled n SERIAL COM. CONTROL n [ENTER] for more SERIAL COMMUNICATION CONTROL: Off Range: On, Off ASSIGN START CONTROL RELAYS: Auxiliary2 Range: Auxiliary2, Aux2 & Aux3, Auxiliary3 ENTER ESCAPE ð ð MESSAGE ESCAPE MESSAGE ESCAPE ENTER ESCAPE ð ð MESSAGE ESCAPE GE Multilin 469 Motor Management Relay 4-15 4 SETPOINTS 4.3 S2 SYSTEM SETUP 4 4.3.5 REDUCED VOLTAGE PATH: SETPOINTS Õ× S2 SYSTEM SETUP Õ× REDUCED VOLTAGE The 469 can control the transition of a reduced voltage starter from reduced to full voltage. That transition may be based on "Current Only", "Current and Timer", or "Current or Timer" (whichever comes first). When the 469 measures the transition of no motor current to some value of motor current, a ’Start’ is assumed to be occurring (typically current will rise quickly to a value in excess of FLA, e.g. 3 × FLA). At this point, the REDUCED VOLTAGE START TIMER is initialized with the programmed value in seconds. • If "Current Only" is selected, when the motor current falls below the user's programmed Transition Level, transition will be initiated by activating the assigned output relay for 1 second. If the timer expires before that transition is initiated, an Incomplete Sequence Trip will occur activating the assigned trip relay(s). • If "Current or Timer" is selected, when the motor current falls below the user's programmed Transition Level, transition will be initiated by activating the assigned output relay for 1 second. If the timer expires before that transition is initiated, the transition will be initiated regardless. • If "Current and Timer" is selected, when the motor current falls below the user's programmed Transition Level and the timer expires, transition will be initiated by activating the assigned output relay for 1 second. If the timer expires before current falls below the Transition Level, an Incomplete Sequence Trip will occur activating the assigned trip relay(s). Figure 4–1: REDUCED VOLTAGE START CONTACTOR CONTROL CIRCUIT n REDUCED VOLTAGE n [ENTER] for more REDUCED VOLTAGE STARTING: Off Range: On, Off ASSIGN CONTROL RELAYS: Auxiliary3 Range: Auxilary2, Aux2 & Aux3, Auxiliary3 TRANSITION ON: Current Only Range: Current Only, Current or Timer, Current and Timer ASSIGN TRIP RELAYS: Trip Range: Trip, Trip & Aux2, Trip & Aux2 & Aux3, Trip & Aux3 REDUCED VOLTAGE START LEVEL: 100% FLA Range: 25 to 300% in steps of 1 REDUCED VOLTAGE START TIMER: 200 s Range: 1 to 600 s in steps of 1 ENTER ESCAPE ð ð MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE 808724A1.CDR CC1 CC2 469 BLOCK TRIP STOP START REDUCED VOLTAGE CONTACTOR FULL VOLTAGE CONTACTOR CC1 SEAL IN 469 R3 AUX CC2 SEAL IN 4-16 469 Motor Management Relay GE Multilin 4.3 S2 SYSTEM SETUP 4 

    2022.12.31.jpg

    手机轮播图2(1)_副本.jpg

    公司简介_副本.jpg



    品牌:ICS TRIPLEX

    型号: ICS TRIPLEX 9402 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号