欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:xiamen2018@foxmail.com

主页 > 产品中心 > SCHNEIDER

SCHNEIDER

ABB >>

A-B>>

GE>>

BENTLY>>

140XBP00400

140XBP00400

主营产品PLC可编程控制器模块,DCS卡件,ESD系统卡件,振动监测系统卡件,汽轮机控制系统模块,燃气发电机备件等,优势品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、P...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

140XBP00400

    主营产品

    PLC可编程控制器模块,DCS卡件,ESD系统卡件,振动监测系统卡件,汽轮机控制系统模块,燃气发电机备件等,优势品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各种进口工业零部件

    产品广泛应用于冶金、石油天然气、玻璃制造业、铝业、石油化工、煤矿、造纸印刷、纺织印染、机械、电子制造、汽车制造、塑胶机械、电力、水利、水处理/环保、锅炉供暖、能源、输配电等等

    140XBP00400脉冲输入模块

    三角模式触发瞬间的定义以及二进制信号如何被记录。配置的模拟信道始终为:记录。可能的设置: TrigByStart:当保护功能拾取(一般拾取)。二进制的不记录信号。

     TrigByTrip:当保护功能跳闸(一般跳闸)。二进制信号是没有记录。

     TrigByBin1:干扰记录器由二进制I/P 1。不记录二进制信号。

     TrigAnyBin:记录定义的二进制信号,并通过或门触发记录。

     TrStrt和Bin:记录定义的二进制信号,并通过或门和

    当保护功能启动时(一般启动)。

     TrTrip和Bin:记录定义的二进制信号,并通过或门和

    当保护功能跳闸时(一般拾取)。三相电流合理性(检查-I3ph)A、 应用检查三相电流输入的合理性:

    监测三相系统的对称性

    剩余电流检测监督c.t.输入通道。B、 特征评估

    三相电流之和

    三相电流的顺序

    用于比较三相电流之和的规定

    具有剩余电流I/P剩余电流幅度的调整

    大电流下的阻塞(大于2 x IN)

    小电流下相序监测的阻塞(小于0.05 x英寸)

    对直流组件不敏感

    对谐波不敏感三相电压合理性(检查-U3ph)

    检查三相电压输入的合理性:剩余电压检测监测三相电压系统的不对称性

    由于零序分量监控v.t.输入通道。

    B、 特征评价三相电压之和

    三相电压的顺序

    用于比较三相电压之和的规定具有剩余电压I/P

    剩余电压幅度的调整高压下的闭锁(高于1.2 x UN)

    小电压下相序监测的阻断(低于0.4 x UN相间电压)

    对直流组件不敏感

    对谐波不敏感。

    只有在Y的情况下才可能评估相电压

    连接的I/P变压器,否则剩余组件无法检测到。

    TrigMode

    Definition of the instant of triggering and how binary signals

    are recorded. The configured analogue channels are always

    recorded. Possible settings:

     TrigByStart: The disturbance recorder is triggered when a

    protection function picks up (general pick-up). Binary

    signals are not recorded.

     TrigByTrip: The disturbance recorder is triggered when a

    protection function trips (general trip). Binary signals are

    not recorded.

     TrigByBin1: The disturbance recorder is triggered by the

    binary I/P 1. Binary signals are not recorded.

     TrigAnyBin: Defined binary signals are recorded and recording is triggered by any of them via an OR gate.

     TrStrt&Bin: Defined binary signals are recorded and recording is triggered by any of them via an OR gate and

    also when a protection function picks up (general pickup).

     TrTrip&Bin: Defined binary signals are recorded and recording is triggered by any of them via an OR gate and

    also when a protection function trips (general pick-up). Three-phase current plausibility (Check-I3ph)

    A. Application

    Checking the plausibility of the three-phase current inputs for

     monitoring the symmetry of the three-phase system

     detection of a residual current

     supervision of the c.t. input channels.

    B. Features

     evaluation of

     the sum of the three phase currents

     the sequence of the three phase currents

     provision for comparing the sum of the three phase currents

    with a residual current I/P

     adjustment of residual current amplitude

     blocking at high currents (higher than 2 x IN)

     blocking of phase sequence monitoring at small currents

    (below 0.05 x IN)

     insensitive to DC components

     insensitive to harmonics Three-phase voltage plausibility (Check-U3ph)

    A. Application

    Checking the plausibility of the three-phase voltage inputs for

     detection of residual voltage

     monitoring the asymmetry of the three-phase voltage system

    due to the zero-sequence component

     supervision of the v.t. input channels.

    B. Features

    evaluation of

     the sum of the three phase voltages

     the sequence of the three phase voltages

     provision for comparing the sum of the three phase voltages

    with a residual voltage I/P

     adjustment of residual voltage amplitude

     blocking at high voltages (higher than 1.2 x UN)

     blocking of phase sequence monitoring at small voltages

    (below 0.4 x UN phase-to-phase voltages)

     insensitive to DC components

     insensitive to harmonics.

    Evaluation of the phase voltages is only possible in the case of Y

    connected I/P transformers, otherwise the residual component

    cannot be detected.

    品牌:140PLC系列

    型号:140XBP00400

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货